Cargando…
Photon-counting detector CT: early clinical experience review
Since its development in the 1970s, X-ray CT has emerged as a landmark diagnostic imaging modality of modern medicine. Technological advances have been crucial to the success of CT imaging, as they have increasingly enabled improvements in image quality and diagnostic value at increasing radiation d...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The British Institute of Radiology.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10321251/ https://www.ncbi.nlm.nih.gov/pubmed/36744809 http://dx.doi.org/10.1259/bjr.20220544 |
_version_ | 1785068587623383040 |
---|---|
author | Sartoretti, Thomas Wildberger, Joachim E Flohr, Thomas Alkadhi, Hatem |
author_facet | Sartoretti, Thomas Wildberger, Joachim E Flohr, Thomas Alkadhi, Hatem |
author_sort | Sartoretti, Thomas |
collection | PubMed |
description | Since its development in the 1970s, X-ray CT has emerged as a landmark diagnostic imaging modality of modern medicine. Technological advances have been crucial to the success of CT imaging, as they have increasingly enabled improvements in image quality and diagnostic value at increasing radiation dose efficiency. With recent advances in engineering and physics, a novel technology has emerged with the potential to surpass several shortcomings and limitations of current CT systems. Photon-counting detector (PCD)-CT might substantially improve and expand the applicability of CT imaging by offering intrinsic spectral capabilities, increased spatial resolution, reduced electronic noise and improved image contrast. In this review we sought to summarize the first clinical experience of PCD-CT. We focused on most recent prototype and first clinically approved PCD-CT systems thereby reviewing initial publications and presenting corresponding clinical cases. |
format | Online Article Text |
id | pubmed-10321251 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The British Institute of Radiology. |
record_format | MEDLINE/PubMed |
spelling | pubmed-103212512023-07-06 Photon-counting detector CT: early clinical experience review Sartoretti, Thomas Wildberger, Joachim E Flohr, Thomas Alkadhi, Hatem Br J Radiol Review Article Since its development in the 1970s, X-ray CT has emerged as a landmark diagnostic imaging modality of modern medicine. Technological advances have been crucial to the success of CT imaging, as they have increasingly enabled improvements in image quality and diagnostic value at increasing radiation dose efficiency. With recent advances in engineering and physics, a novel technology has emerged with the potential to surpass several shortcomings and limitations of current CT systems. Photon-counting detector (PCD)-CT might substantially improve and expand the applicability of CT imaging by offering intrinsic spectral capabilities, increased spatial resolution, reduced electronic noise and improved image contrast. In this review we sought to summarize the first clinical experience of PCD-CT. We focused on most recent prototype and first clinically approved PCD-CT systems thereby reviewing initial publications and presenting corresponding clinical cases. The British Institute of Radiology. 2023-07-01 2023-02-10 /pmc/articles/PMC10321251/ /pubmed/36744809 http://dx.doi.org/10.1259/bjr.20220544 Text en © 2023 The Authors. Published by the British Institute of Radiology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 Unported License http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) , which permits unrestricted non-commercial reuse, provided the original author and source are credited. |
spellingShingle | Review Article Sartoretti, Thomas Wildberger, Joachim E Flohr, Thomas Alkadhi, Hatem Photon-counting detector CT: early clinical experience review |
title | Photon-counting detector CT: early clinical experience review |
title_full | Photon-counting detector CT: early clinical experience review |
title_fullStr | Photon-counting detector CT: early clinical experience review |
title_full_unstemmed | Photon-counting detector CT: early clinical experience review |
title_short | Photon-counting detector CT: early clinical experience review |
title_sort | photon-counting detector ct: early clinical experience review |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10321251/ https://www.ncbi.nlm.nih.gov/pubmed/36744809 http://dx.doi.org/10.1259/bjr.20220544 |
work_keys_str_mv | AT sartorettithomas photoncountingdetectorctearlyclinicalexperiencereview AT wildbergerjoachime photoncountingdetectorctearlyclinicalexperiencereview AT flohrthomas photoncountingdetectorctearlyclinicalexperiencereview AT alkadhihatem photoncountingdetectorctearlyclinicalexperiencereview |