Cargando…

Influence of tension-band plates on the mechanical loading of the femoral growth plate during guided growth due to coronal plane deformities

Introduction: Correction of knee malalignment by guided growth using a tension-band plate is a common therapy to prevent knee osteoarthritis among other things. This approach is based on the Hueter-Volkmann law stating that the length growth of bones is inhibited by compression and stimulated by ten...

Descripción completa

Detalles Bibliográficos
Autores principales: Hucke, Lucie, Holder, Jana, van Drongelen, Stefan, Stief, Felix, Gámez, Antonio J., Huß, Armin, Wittek, Andreas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10321528/
https://www.ncbi.nlm.nih.gov/pubmed/37415789
http://dx.doi.org/10.3389/fbioe.2023.1165963
_version_ 1785068632919769088
author Hucke, Lucie
Holder, Jana
van Drongelen, Stefan
Stief, Felix
Gámez, Antonio J.
Huß, Armin
Wittek, Andreas
author_facet Hucke, Lucie
Holder, Jana
van Drongelen, Stefan
Stief, Felix
Gámez, Antonio J.
Huß, Armin
Wittek, Andreas
author_sort Hucke, Lucie
collection PubMed
description Introduction: Correction of knee malalignment by guided growth using a tension-band plate is a common therapy to prevent knee osteoarthritis among other things. This approach is based on the Hueter-Volkmann law stating that the length growth of bones is inhibited by compression and stimulated by tension. How the locally varying mechanical loading of the growth plate is influenced by the implant has not yet been investigated. This study combines load cases from the gait cycle with personalized geometry in order to investigate the mechanical influence of the tension-band plates. Methods: Personalized finite element models of four distal femoral epiphyses of three individuals, that had undergone guided growth, were generated. Load cases from the gait cycles and musculoskeletal modelling were simulated with and without implant. Morphological features of the growth plates were obtained from radiographs. 3D geometries were completed using non-individual Magnetic Resonance Images of age-matched individuals. Boundary conditions for the models were obtained from instrumented gait analyses. Results: The stress distribution in the growth plate was heterogenous and depended on the geometry. In the insertion region, the implants locally induced static stress and reduced the cyclic loading and unloading. Both factors that reduce the growth rate. On the contralateral side of the growth plate, increased tension stress was observed, which stimulates growth. Discussion: Personalized finite element models are able to estimate the changes of local static and cyclic loading of the growth plate induced by the implant. In future, this knowledge can help to better control growth modulation and avoid the return of the malalignment after the treatment. However, this requires models that are completely participant-specific in terms of load cases and 3D geometry.
format Online
Article
Text
id pubmed-10321528
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-103215282023-07-06 Influence of tension-band plates on the mechanical loading of the femoral growth plate during guided growth due to coronal plane deformities Hucke, Lucie Holder, Jana van Drongelen, Stefan Stief, Felix Gámez, Antonio J. Huß, Armin Wittek, Andreas Front Bioeng Biotechnol Bioengineering and Biotechnology Introduction: Correction of knee malalignment by guided growth using a tension-band plate is a common therapy to prevent knee osteoarthritis among other things. This approach is based on the Hueter-Volkmann law stating that the length growth of bones is inhibited by compression and stimulated by tension. How the locally varying mechanical loading of the growth plate is influenced by the implant has not yet been investigated. This study combines load cases from the gait cycle with personalized geometry in order to investigate the mechanical influence of the tension-band plates. Methods: Personalized finite element models of four distal femoral epiphyses of three individuals, that had undergone guided growth, were generated. Load cases from the gait cycles and musculoskeletal modelling were simulated with and without implant. Morphological features of the growth plates were obtained from radiographs. 3D geometries were completed using non-individual Magnetic Resonance Images of age-matched individuals. Boundary conditions for the models were obtained from instrumented gait analyses. Results: The stress distribution in the growth plate was heterogenous and depended on the geometry. In the insertion region, the implants locally induced static stress and reduced the cyclic loading and unloading. Both factors that reduce the growth rate. On the contralateral side of the growth plate, increased tension stress was observed, which stimulates growth. Discussion: Personalized finite element models are able to estimate the changes of local static and cyclic loading of the growth plate induced by the implant. In future, this knowledge can help to better control growth modulation and avoid the return of the malalignment after the treatment. However, this requires models that are completely participant-specific in terms of load cases and 3D geometry. Frontiers Media S.A. 2023-06-21 /pmc/articles/PMC10321528/ /pubmed/37415789 http://dx.doi.org/10.3389/fbioe.2023.1165963 Text en Copyright © 2023 Hucke, Holder, van Drongelen, Stief, Gámez, Huß and Wittek. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Hucke, Lucie
Holder, Jana
van Drongelen, Stefan
Stief, Felix
Gámez, Antonio J.
Huß, Armin
Wittek, Andreas
Influence of tension-band plates on the mechanical loading of the femoral growth plate during guided growth due to coronal plane deformities
title Influence of tension-band plates on the mechanical loading of the femoral growth plate during guided growth due to coronal plane deformities
title_full Influence of tension-band plates on the mechanical loading of the femoral growth plate during guided growth due to coronal plane deformities
title_fullStr Influence of tension-band plates on the mechanical loading of the femoral growth plate during guided growth due to coronal plane deformities
title_full_unstemmed Influence of tension-band plates on the mechanical loading of the femoral growth plate during guided growth due to coronal plane deformities
title_short Influence of tension-band plates on the mechanical loading of the femoral growth plate during guided growth due to coronal plane deformities
title_sort influence of tension-band plates on the mechanical loading of the femoral growth plate during guided growth due to coronal plane deformities
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10321528/
https://www.ncbi.nlm.nih.gov/pubmed/37415789
http://dx.doi.org/10.3389/fbioe.2023.1165963
work_keys_str_mv AT huckelucie influenceoftensionbandplatesonthemechanicalloadingofthefemoralgrowthplateduringguidedgrowthduetocoronalplanedeformities
AT holderjana influenceoftensionbandplatesonthemechanicalloadingofthefemoralgrowthplateduringguidedgrowthduetocoronalplanedeformities
AT vandrongelenstefan influenceoftensionbandplatesonthemechanicalloadingofthefemoralgrowthplateduringguidedgrowthduetocoronalplanedeformities
AT stieffelix influenceoftensionbandplatesonthemechanicalloadingofthefemoralgrowthplateduringguidedgrowthduetocoronalplanedeformities
AT gamezantonioj influenceoftensionbandplatesonthemechanicalloadingofthefemoralgrowthplateduringguidedgrowthduetocoronalplanedeformities
AT hußarmin influenceoftensionbandplatesonthemechanicalloadingofthefemoralgrowthplateduringguidedgrowthduetocoronalplanedeformities
AT wittekandreas influenceoftensionbandplatesonthemechanicalloadingofthefemoralgrowthplateduringguidedgrowthduetocoronalplanedeformities