Cargando…

Mechanically induced electrical storm as a complication of cardiac resynchronization therapy: A case report()

BACKGROUND: Cardiac resynchronization therapy (CRT) has been shown to improve both the functional status and mortality of heart failure patients with left bundle branch block. Multiple recent studies suggest several mechanisms for proarrhythmia associated with CRT device. CASE SUMMARY: A 51-year-old...

Descripción completa

Detalles Bibliográficos
Autores principales: Feng, Zekun, Marcus, Gregory M., Badhwar, Nitish
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10323185/
https://www.ncbi.nlm.nih.gov/pubmed/37196771
http://dx.doi.org/10.1016/j.ipej.2023.05.001
_version_ 1785068914500173824
author Feng, Zekun
Marcus, Gregory M.
Badhwar, Nitish
author_facet Feng, Zekun
Marcus, Gregory M.
Badhwar, Nitish
author_sort Feng, Zekun
collection PubMed
description BACKGROUND: Cardiac resynchronization therapy (CRT) has been shown to improve both the functional status and mortality of heart failure patients with left bundle branch block. Multiple recent studies suggest several mechanisms for proarrhythmia associated with CRT device. CASE SUMMARY: A 51-year-old male with symptomatic non-ischemic cardiomyopathy and no previous history of ventricular arrhythmias underwent placement of a biventricular cardioverter-defibrillator. The patient developed sustained monomorphic ventricular tachycardia (VT) soon after implantation. The VT recurred despite reprogramming to right ventricular only pacing. The electrical storm resolved only after a subsequent discharge from the defibrillator caused inadvertent dislodgement of the coronary sinus lead. No recurrent VT occurred throughout 10-years follow up after urgent coronary sinus lead revision. DISCUSSION: We describe the first reported case of mechanically induced electrical storm due to the physical presence of the CS lead in a patient with a new CRT-D device. It is important to recognize mechanical proarrhythmia as a potential mechanism of electrical storm, as it may be intractable to device reprogramming. Urgent coronary sinus lead revision should be considered. Further studies on this mechanism of proarrhythmia are needed.
format Online
Article
Text
id pubmed-10323185
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-103231852023-07-07 Mechanically induced electrical storm as a complication of cardiac resynchronization therapy: A case report() Feng, Zekun Marcus, Gregory M. Badhwar, Nitish Indian Pacing Electrophysiol J Case Report BACKGROUND: Cardiac resynchronization therapy (CRT) has been shown to improve both the functional status and mortality of heart failure patients with left bundle branch block. Multiple recent studies suggest several mechanisms for proarrhythmia associated with CRT device. CASE SUMMARY: A 51-year-old male with symptomatic non-ischemic cardiomyopathy and no previous history of ventricular arrhythmias underwent placement of a biventricular cardioverter-defibrillator. The patient developed sustained monomorphic ventricular tachycardia (VT) soon after implantation. The VT recurred despite reprogramming to right ventricular only pacing. The electrical storm resolved only after a subsequent discharge from the defibrillator caused inadvertent dislodgement of the coronary sinus lead. No recurrent VT occurred throughout 10-years follow up after urgent coronary sinus lead revision. DISCUSSION: We describe the first reported case of mechanically induced electrical storm due to the physical presence of the CS lead in a patient with a new CRT-D device. It is important to recognize mechanical proarrhythmia as a potential mechanism of electrical storm, as it may be intractable to device reprogramming. Urgent coronary sinus lead revision should be considered. Further studies on this mechanism of proarrhythmia are needed. Elsevier 2023-05-15 /pmc/articles/PMC10323185/ /pubmed/37196771 http://dx.doi.org/10.1016/j.ipej.2023.05.001 Text en © 2023 Indian Heart Rhythm Society. Published by Elsevier B.V. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Feng, Zekun
Marcus, Gregory M.
Badhwar, Nitish
Mechanically induced electrical storm as a complication of cardiac resynchronization therapy: A case report()
title Mechanically induced electrical storm as a complication of cardiac resynchronization therapy: A case report()
title_full Mechanically induced electrical storm as a complication of cardiac resynchronization therapy: A case report()
title_fullStr Mechanically induced electrical storm as a complication of cardiac resynchronization therapy: A case report()
title_full_unstemmed Mechanically induced electrical storm as a complication of cardiac resynchronization therapy: A case report()
title_short Mechanically induced electrical storm as a complication of cardiac resynchronization therapy: A case report()
title_sort mechanically induced electrical storm as a complication of cardiac resynchronization therapy: a case report()
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10323185/
https://www.ncbi.nlm.nih.gov/pubmed/37196771
http://dx.doi.org/10.1016/j.ipej.2023.05.001
work_keys_str_mv AT fengzekun mechanicallyinducedelectricalstormasacomplicationofcardiacresynchronizationtherapyacasereport
AT marcusgregorym mechanicallyinducedelectricalstormasacomplicationofcardiacresynchronizationtherapyacasereport
AT badhwarnitish mechanicallyinducedelectricalstormasacomplicationofcardiacresynchronizationtherapyacasereport