Correct Closure of the Left Atrial Appendage Reduces Stagnant Blood Flow and the Risk of Thrombus Formation: A Proof-of-Concept Experimental Study Using 4D Flow Magnetic Resonance Imaging
OBJECTIVE: The study was conducted to investigate the effect of correct occlusion of the left atrial appendage (LAA) on intracardiac blood flow and thrombus formation in patients with atrial fibrillation (AF) using four-dimensional (4D) flow magnetic resonance imaging (MRI) and three-dimensional (3D...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10323417/ https://www.ncbi.nlm.nih.gov/pubmed/37404107 http://dx.doi.org/10.3348/kjr.2023.0173 |
_version_ | 1785068954395344896 |
---|---|
author | Cha, Min Jae An, Don-Gwan Kang, Minsoo Kim, Hyue Mee Kim, Sang-Wook Cho, Iksung Hong, Joonhwa Choi, Hyewon Cho, Jee-Hyun Shin, Seung Yong Song, Simon |
author_facet | Cha, Min Jae An, Don-Gwan Kang, Minsoo Kim, Hyue Mee Kim, Sang-Wook Cho, Iksung Hong, Joonhwa Choi, Hyewon Cho, Jee-Hyun Shin, Seung Yong Song, Simon |
author_sort | Cha, Min Jae |
collection | PubMed |
description | OBJECTIVE: The study was conducted to investigate the effect of correct occlusion of the left atrial appendage (LAA) on intracardiac blood flow and thrombus formation in patients with atrial fibrillation (AF) using four-dimensional (4D) flow magnetic resonance imaging (MRI) and three-dimensional (3D)-printed phantoms. MATERIALS AND METHODS: Three life-sized 3D-printed left atrium (LA) phantoms, including a pre-occlusion (i.e., before the occlusion procedure) model and correctly and incorrectly occluded post-procedural models, were constructed based on cardiac computed tomography images from an 86-year-old male with long-standing persistent AF. A custom-made closed-loop flow circuit was set up, and pulsatile simulated pulmonary venous flow was delivered by a pump. 4D flow MRI was performed using a 3T scanner, and the images were analyzed using MATLAB-based software (R2020b; Mathworks). Flow metrics associated with blood stasis and thrombogenicity, such as the volume of stasis defined by the velocity threshold ([Formula: see text] < 3 cm/s), surface-and-time-averaged wall shear stress (WSS), and endothelial cell activation potential (ECAP), were analyzed and compared among the three LA phantom models. RESULTS: Different spatial distributions, orientations, and magnitudes of LA flow were directly visualized within the three LA phantoms using 4D flow MRI. The time-averaged volume and its ratio to the corresponding entire volume of LA flow stasis were consistently reduced in the correctly occluded model (70.82 mL and 39.0%, respectively), followed by the incorrectly occluded (73.17 mL and 39.0%, respectively) and pre-occlusion (79.11 mL and 39.7%, respectively) models. The surface-and-time-averaged WSS and ECAP were also lowest in the correctly occluded model (0.048 Pa and 4.004 Pa(-1) , respectively), followed by the incorrectly occluded (0.059 Pa and 4.792 Pa(-1) , respectively) and pre-occlusion (0.072 Pa and 5.861 Pa(-1) , respectively) models. CONCLUSION: These findings suggest that a correctly occluded LAA leads to the greatest reduction in LA flow stasis and thrombogenicity, presenting a tentative procedural goal to maximize clinical benefits in patients with AF. |
format | Online Article Text |
id | pubmed-10323417 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-103234172023-07-07 Correct Closure of the Left Atrial Appendage Reduces Stagnant Blood Flow and the Risk of Thrombus Formation: A Proof-of-Concept Experimental Study Using 4D Flow Magnetic Resonance Imaging Cha, Min Jae An, Don-Gwan Kang, Minsoo Kim, Hyue Mee Kim, Sang-Wook Cho, Iksung Hong, Joonhwa Choi, Hyewon Cho, Jee-Hyun Shin, Seung Yong Song, Simon Korean J Radiol Cardiovascular Imaging OBJECTIVE: The study was conducted to investigate the effect of correct occlusion of the left atrial appendage (LAA) on intracardiac blood flow and thrombus formation in patients with atrial fibrillation (AF) using four-dimensional (4D) flow magnetic resonance imaging (MRI) and three-dimensional (3D)-printed phantoms. MATERIALS AND METHODS: Three life-sized 3D-printed left atrium (LA) phantoms, including a pre-occlusion (i.e., before the occlusion procedure) model and correctly and incorrectly occluded post-procedural models, were constructed based on cardiac computed tomography images from an 86-year-old male with long-standing persistent AF. A custom-made closed-loop flow circuit was set up, and pulsatile simulated pulmonary venous flow was delivered by a pump. 4D flow MRI was performed using a 3T scanner, and the images were analyzed using MATLAB-based software (R2020b; Mathworks). Flow metrics associated with blood stasis and thrombogenicity, such as the volume of stasis defined by the velocity threshold ([Formula: see text] < 3 cm/s), surface-and-time-averaged wall shear stress (WSS), and endothelial cell activation potential (ECAP), were analyzed and compared among the three LA phantom models. RESULTS: Different spatial distributions, orientations, and magnitudes of LA flow were directly visualized within the three LA phantoms using 4D flow MRI. The time-averaged volume and its ratio to the corresponding entire volume of LA flow stasis were consistently reduced in the correctly occluded model (70.82 mL and 39.0%, respectively), followed by the incorrectly occluded (73.17 mL and 39.0%, respectively) and pre-occlusion (79.11 mL and 39.7%, respectively) models. The surface-and-time-averaged WSS and ECAP were also lowest in the correctly occluded model (0.048 Pa and 4.004 Pa(-1) , respectively), followed by the incorrectly occluded (0.059 Pa and 4.792 Pa(-1) , respectively) and pre-occlusion (0.072 Pa and 5.861 Pa(-1) , respectively) models. CONCLUSION: These findings suggest that a correctly occluded LAA leads to the greatest reduction in LA flow stasis and thrombogenicity, presenting a tentative procedural goal to maximize clinical benefits in patients with AF. The Korean Society of Radiology 2023-07 2023-06-09 /pmc/articles/PMC10323417/ /pubmed/37404107 http://dx.doi.org/10.3348/kjr.2023.0173 Text en Copyright © 2023 The Korean Society of Radiology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Cardiovascular Imaging Cha, Min Jae An, Don-Gwan Kang, Minsoo Kim, Hyue Mee Kim, Sang-Wook Cho, Iksung Hong, Joonhwa Choi, Hyewon Cho, Jee-Hyun Shin, Seung Yong Song, Simon Correct Closure of the Left Atrial Appendage Reduces Stagnant Blood Flow and the Risk of Thrombus Formation: A Proof-of-Concept Experimental Study Using 4D Flow Magnetic Resonance Imaging |
title | Correct Closure of the Left Atrial Appendage Reduces Stagnant Blood Flow and the Risk of Thrombus Formation: A Proof-of-Concept Experimental Study Using 4D Flow Magnetic Resonance Imaging |
title_full | Correct Closure of the Left Atrial Appendage Reduces Stagnant Blood Flow and the Risk of Thrombus Formation: A Proof-of-Concept Experimental Study Using 4D Flow Magnetic Resonance Imaging |
title_fullStr | Correct Closure of the Left Atrial Appendage Reduces Stagnant Blood Flow and the Risk of Thrombus Formation: A Proof-of-Concept Experimental Study Using 4D Flow Magnetic Resonance Imaging |
title_full_unstemmed | Correct Closure of the Left Atrial Appendage Reduces Stagnant Blood Flow and the Risk of Thrombus Formation: A Proof-of-Concept Experimental Study Using 4D Flow Magnetic Resonance Imaging |
title_short | Correct Closure of the Left Atrial Appendage Reduces Stagnant Blood Flow and the Risk of Thrombus Formation: A Proof-of-Concept Experimental Study Using 4D Flow Magnetic Resonance Imaging |
title_sort | correct closure of the left atrial appendage reduces stagnant blood flow and the risk of thrombus formation: a proof-of-concept experimental study using 4d flow magnetic resonance imaging |
topic | Cardiovascular Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10323417/ https://www.ncbi.nlm.nih.gov/pubmed/37404107 http://dx.doi.org/10.3348/kjr.2023.0173 |
work_keys_str_mv | AT chaminjae correctclosureoftheleftatrialappendagereducesstagnantbloodflowandtheriskofthrombusformationaproofofconceptexperimentalstudyusing4dflowmagneticresonanceimaging AT andongwan correctclosureoftheleftatrialappendagereducesstagnantbloodflowandtheriskofthrombusformationaproofofconceptexperimentalstudyusing4dflowmagneticresonanceimaging AT kangminsoo correctclosureoftheleftatrialappendagereducesstagnantbloodflowandtheriskofthrombusformationaproofofconceptexperimentalstudyusing4dflowmagneticresonanceimaging AT kimhyuemee correctclosureoftheleftatrialappendagereducesstagnantbloodflowandtheriskofthrombusformationaproofofconceptexperimentalstudyusing4dflowmagneticresonanceimaging AT kimsangwook correctclosureoftheleftatrialappendagereducesstagnantbloodflowandtheriskofthrombusformationaproofofconceptexperimentalstudyusing4dflowmagneticresonanceimaging AT choiksung correctclosureoftheleftatrialappendagereducesstagnantbloodflowandtheriskofthrombusformationaproofofconceptexperimentalstudyusing4dflowmagneticresonanceimaging AT hongjoonhwa correctclosureoftheleftatrialappendagereducesstagnantbloodflowandtheriskofthrombusformationaproofofconceptexperimentalstudyusing4dflowmagneticresonanceimaging AT choihyewon correctclosureoftheleftatrialappendagereducesstagnantbloodflowandtheriskofthrombusformationaproofofconceptexperimentalstudyusing4dflowmagneticresonanceimaging AT chojeehyun correctclosureoftheleftatrialappendagereducesstagnantbloodflowandtheriskofthrombusformationaproofofconceptexperimentalstudyusing4dflowmagneticresonanceimaging AT shinseungyong correctclosureoftheleftatrialappendagereducesstagnantbloodflowandtheriskofthrombusformationaproofofconceptexperimentalstudyusing4dflowmagneticresonanceimaging AT songsimon correctclosureoftheleftatrialappendagereducesstagnantbloodflowandtheriskofthrombusformationaproofofconceptexperimentalstudyusing4dflowmagneticresonanceimaging |