Cargando…

Rapid cardiac ischemia detection with an epicardial graphene probe

INTRODUCTION: In this study, a new probe was designed to enable electrocardiography of a rotated heart during cardiac surgery when skin electrodes became non-functional. This probe adhered non-invasively to the epicardium and collected the ECG signal independently from the position of the heart. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Suwalski, Grzegorz, Galanty, Marek, Degórska, Beata, Sterna, Jacek, Frymus, Jan, Baranski, Mikhal, Trębacz, Piotr, Janczak, Daniel, Lepak-Kuc, Sandra, Jakubowska, Małgorzata
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10323424/
https://www.ncbi.nlm.nih.gov/pubmed/37424902
http://dx.doi.org/10.3389/fcvm.2023.1111651
_version_ 1785068956070969344
author Suwalski, Grzegorz
Galanty, Marek
Degórska, Beata
Sterna, Jacek
Frymus, Jan
Baranski, Mikhal
Trębacz, Piotr
Janczak, Daniel
Lepak-Kuc, Sandra
Jakubowska, Małgorzata
author_facet Suwalski, Grzegorz
Galanty, Marek
Degórska, Beata
Sterna, Jacek
Frymus, Jan
Baranski, Mikhal
Trębacz, Piotr
Janczak, Daniel
Lepak-Kuc, Sandra
Jakubowska, Małgorzata
author_sort Suwalski, Grzegorz
collection PubMed
description INTRODUCTION: In this study, a new probe was designed to enable electrocardiography of a rotated heart during cardiac surgery when skin electrodes became non-functional. This probe adhered non-invasively to the epicardium and collected the ECG signal independently from the position of the heart. The study compared the accuracy of cardiac ischemia detection between classic skin and epicardial electrodes in an animal model. METHODS: Using six pigs, an open chest model was devised with cardiac ischemia induction by coronary artery ligation in two non-physiologic heart positions. Both the accuracy and the time of detection of electrocardiographic symptoms of acute cardiac ischemia were compared between skin and epicardial methods of signal collection. RESULTS: Heart rotation to expose either the anterior or the posterior wall resulted in a distortion or loss of the ECG signal collected by skin electrodes after coronary artery ligation, standard skin ECG monitoring did not reveal any ischemia symptoms. Attachment of an epicardial probe on the anterior and posterior walls helped in the recovery of the normal ECG wave. After ligation of the coronary artery, the epicardial probes recorded cardiac ischemia within 40 s. DISCUSSION: This study highlighted the effectiveness of ECG monitoring with epicardial probes in a rotated heart. It can be concluded that epicardial probes can detect the presence of acute ischemia of a rotated heart when skin ECG monitoring becomes ineffective.
format Online
Article
Text
id pubmed-10323424
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-103234242023-07-07 Rapid cardiac ischemia detection with an epicardial graphene probe Suwalski, Grzegorz Galanty, Marek Degórska, Beata Sterna, Jacek Frymus, Jan Baranski, Mikhal Trębacz, Piotr Janczak, Daniel Lepak-Kuc, Sandra Jakubowska, Małgorzata Front Cardiovasc Med Cardiovascular Medicine INTRODUCTION: In this study, a new probe was designed to enable electrocardiography of a rotated heart during cardiac surgery when skin electrodes became non-functional. This probe adhered non-invasively to the epicardium and collected the ECG signal independently from the position of the heart. The study compared the accuracy of cardiac ischemia detection between classic skin and epicardial electrodes in an animal model. METHODS: Using six pigs, an open chest model was devised with cardiac ischemia induction by coronary artery ligation in two non-physiologic heart positions. Both the accuracy and the time of detection of electrocardiographic symptoms of acute cardiac ischemia were compared between skin and epicardial methods of signal collection. RESULTS: Heart rotation to expose either the anterior or the posterior wall resulted in a distortion or loss of the ECG signal collected by skin electrodes after coronary artery ligation, standard skin ECG monitoring did not reveal any ischemia symptoms. Attachment of an epicardial probe on the anterior and posterior walls helped in the recovery of the normal ECG wave. After ligation of the coronary artery, the epicardial probes recorded cardiac ischemia within 40 s. DISCUSSION: This study highlighted the effectiveness of ECG monitoring with epicardial probes in a rotated heart. It can be concluded that epicardial probes can detect the presence of acute ischemia of a rotated heart when skin ECG monitoring becomes ineffective. Frontiers Media S.A. 2023-06-22 /pmc/articles/PMC10323424/ /pubmed/37424902 http://dx.doi.org/10.3389/fcvm.2023.1111651 Text en © 2023 Suwalski, Galanty, Degórska, Sterna, Frymus, Baranski, Trębacz, Janczak, Lepak-Kuc and Jakubowska. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Suwalski, Grzegorz
Galanty, Marek
Degórska, Beata
Sterna, Jacek
Frymus, Jan
Baranski, Mikhal
Trębacz, Piotr
Janczak, Daniel
Lepak-Kuc, Sandra
Jakubowska, Małgorzata
Rapid cardiac ischemia detection with an epicardial graphene probe
title Rapid cardiac ischemia detection with an epicardial graphene probe
title_full Rapid cardiac ischemia detection with an epicardial graphene probe
title_fullStr Rapid cardiac ischemia detection with an epicardial graphene probe
title_full_unstemmed Rapid cardiac ischemia detection with an epicardial graphene probe
title_short Rapid cardiac ischemia detection with an epicardial graphene probe
title_sort rapid cardiac ischemia detection with an epicardial graphene probe
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10323424/
https://www.ncbi.nlm.nih.gov/pubmed/37424902
http://dx.doi.org/10.3389/fcvm.2023.1111651
work_keys_str_mv AT suwalskigrzegorz rapidcardiacischemiadetectionwithanepicardialgrapheneprobe
AT galantymarek rapidcardiacischemiadetectionwithanepicardialgrapheneprobe
AT degorskabeata rapidcardiacischemiadetectionwithanepicardialgrapheneprobe
AT sternajacek rapidcardiacischemiadetectionwithanepicardialgrapheneprobe
AT frymusjan rapidcardiacischemiadetectionwithanepicardialgrapheneprobe
AT baranskimikhal rapidcardiacischemiadetectionwithanepicardialgrapheneprobe
AT trebaczpiotr rapidcardiacischemiadetectionwithanepicardialgrapheneprobe
AT janczakdaniel rapidcardiacischemiadetectionwithanepicardialgrapheneprobe
AT lepakkucsandra rapidcardiacischemiadetectionwithanepicardialgrapheneprobe
AT jakubowskamałgorzata rapidcardiacischemiadetectionwithanepicardialgrapheneprobe