Cargando…

A method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram

BACKGROUND: Ultrasonic echocardiography is commonly used for monitoring myocardial dysfunction. However, it has limitations such as poor quality of echocardiography images and subjective judgment of doctors. METHODS: In this paper, a calculation model based on optical flow tracking of echocardiogram...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Shanna, Zhang, Hao, Li, Chang, Dai, Weifang, Wu, Jinyu, Wu, Yuanyuan, Su, Wenwen, Xia, Bin, Zhou, Jiayu, Shen, Yuqiang, Zhu, Xinjian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10324115/
https://www.ncbi.nlm.nih.gov/pubmed/37407909
http://dx.doi.org/10.1186/s12880-023-01040-3
_version_ 1785069079678156800
author Liu, Shanna
Zhang, Hao
Li, Chang
Dai, Weifang
Wu, Jinyu
Wu, Yuanyuan
Su, Wenwen
Xia, Bin
Zhou, Jiayu
Shen, Yuqiang
Zhu, Xinjian
author_facet Liu, Shanna
Zhang, Hao
Li, Chang
Dai, Weifang
Wu, Jinyu
Wu, Yuanyuan
Su, Wenwen
Xia, Bin
Zhou, Jiayu
Shen, Yuqiang
Zhu, Xinjian
author_sort Liu, Shanna
collection PubMed
description BACKGROUND: Ultrasonic echocardiography is commonly used for monitoring myocardial dysfunction. However, it has limitations such as poor quality of echocardiography images and subjective judgment of doctors. METHODS: In this paper, a calculation model based on optical flow tracking of echocardiogram is proposed for the quantitative estimation motion of the segmental wall. To improve the accuracy of optical flow estimation, a method based on confidence-optimized multiresolution(COM) optical flow model is proposed to reduce the estimation errors caused by the large amplitude of myocardial motion and the presence of “shadows” and other image quality problems. In addition, motion vector decomposition and dynamic tracking of the ventricular region of interest are used to extract information regarding the myocardial segmental motion. The proposed method was validated using simulation images and 50 clinical cases (25 patients and 25 healthy volunteers) for myocardial motion analysis. RESULTS: The results demonstrated that the proposed method could track the motion information of myocardial segments well and reduce the estimation errors of optical flow caused due to the use of low-quality echocardiogram images. CONCLUSIONS: The proposed method improves the accuracy of motion estimation for the cardiac ventricular wall.
format Online
Article
Text
id pubmed-10324115
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-103241152023-07-07 A method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram Liu, Shanna Zhang, Hao Li, Chang Dai, Weifang Wu, Jinyu Wu, Yuanyuan Su, Wenwen Xia, Bin Zhou, Jiayu Shen, Yuqiang Zhu, Xinjian BMC Med Imaging Research BACKGROUND: Ultrasonic echocardiography is commonly used for monitoring myocardial dysfunction. However, it has limitations such as poor quality of echocardiography images and subjective judgment of doctors. METHODS: In this paper, a calculation model based on optical flow tracking of echocardiogram is proposed for the quantitative estimation motion of the segmental wall. To improve the accuracy of optical flow estimation, a method based on confidence-optimized multiresolution(COM) optical flow model is proposed to reduce the estimation errors caused by the large amplitude of myocardial motion and the presence of “shadows” and other image quality problems. In addition, motion vector decomposition and dynamic tracking of the ventricular region of interest are used to extract information regarding the myocardial segmental motion. The proposed method was validated using simulation images and 50 clinical cases (25 patients and 25 healthy volunteers) for myocardial motion analysis. RESULTS: The results demonstrated that the proposed method could track the motion information of myocardial segments well and reduce the estimation errors of optical flow caused due to the use of low-quality echocardiogram images. CONCLUSIONS: The proposed method improves the accuracy of motion estimation for the cardiac ventricular wall. BioMed Central 2023-07-05 /pmc/articles/PMC10324115/ /pubmed/37407909 http://dx.doi.org/10.1186/s12880-023-01040-3 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Liu, Shanna
Zhang, Hao
Li, Chang
Dai, Weifang
Wu, Jinyu
Wu, Yuanyuan
Su, Wenwen
Xia, Bin
Zhou, Jiayu
Shen, Yuqiang
Zhu, Xinjian
A method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram
title A method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram
title_full A method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram
title_fullStr A method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram
title_full_unstemmed A method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram
title_short A method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram
title_sort method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10324115/
https://www.ncbi.nlm.nih.gov/pubmed/37407909
http://dx.doi.org/10.1186/s12880-023-01040-3
work_keys_str_mv AT liushanna amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT zhanghao amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT lichang amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT daiweifang amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT wujinyu amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT wuyuanyuan amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT suwenwen amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT xiabin amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT zhoujiayu amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT shenyuqiang amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT zhuxinjian amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT liushanna methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT zhanghao methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT lichang methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT daiweifang methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT wujinyu methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT wuyuanyuan methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT suwenwen methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT xiabin methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT zhoujiayu methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT shenyuqiang methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram
AT zhuxinjian methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram