Cargando…
A method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram
BACKGROUND: Ultrasonic echocardiography is commonly used for monitoring myocardial dysfunction. However, it has limitations such as poor quality of echocardiography images and subjective judgment of doctors. METHODS: In this paper, a calculation model based on optical flow tracking of echocardiogram...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10324115/ https://www.ncbi.nlm.nih.gov/pubmed/37407909 http://dx.doi.org/10.1186/s12880-023-01040-3 |
_version_ | 1785069079678156800 |
---|---|
author | Liu, Shanna Zhang, Hao Li, Chang Dai, Weifang Wu, Jinyu Wu, Yuanyuan Su, Wenwen Xia, Bin Zhou, Jiayu Shen, Yuqiang Zhu, Xinjian |
author_facet | Liu, Shanna Zhang, Hao Li, Chang Dai, Weifang Wu, Jinyu Wu, Yuanyuan Su, Wenwen Xia, Bin Zhou, Jiayu Shen, Yuqiang Zhu, Xinjian |
author_sort | Liu, Shanna |
collection | PubMed |
description | BACKGROUND: Ultrasonic echocardiography is commonly used for monitoring myocardial dysfunction. However, it has limitations such as poor quality of echocardiography images and subjective judgment of doctors. METHODS: In this paper, a calculation model based on optical flow tracking of echocardiogram is proposed for the quantitative estimation motion of the segmental wall. To improve the accuracy of optical flow estimation, a method based on confidence-optimized multiresolution(COM) optical flow model is proposed to reduce the estimation errors caused by the large amplitude of myocardial motion and the presence of “shadows” and other image quality problems. In addition, motion vector decomposition and dynamic tracking of the ventricular region of interest are used to extract information regarding the myocardial segmental motion. The proposed method was validated using simulation images and 50 clinical cases (25 patients and 25 healthy volunteers) for myocardial motion analysis. RESULTS: The results demonstrated that the proposed method could track the motion information of myocardial segments well and reduce the estimation errors of optical flow caused due to the use of low-quality echocardiogram images. CONCLUSIONS: The proposed method improves the accuracy of motion estimation for the cardiac ventricular wall. |
format | Online Article Text |
id | pubmed-10324115 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-103241152023-07-07 A method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram Liu, Shanna Zhang, Hao Li, Chang Dai, Weifang Wu, Jinyu Wu, Yuanyuan Su, Wenwen Xia, Bin Zhou, Jiayu Shen, Yuqiang Zhu, Xinjian BMC Med Imaging Research BACKGROUND: Ultrasonic echocardiography is commonly used for monitoring myocardial dysfunction. However, it has limitations such as poor quality of echocardiography images and subjective judgment of doctors. METHODS: In this paper, a calculation model based on optical flow tracking of echocardiogram is proposed for the quantitative estimation motion of the segmental wall. To improve the accuracy of optical flow estimation, a method based on confidence-optimized multiresolution(COM) optical flow model is proposed to reduce the estimation errors caused by the large amplitude of myocardial motion and the presence of “shadows” and other image quality problems. In addition, motion vector decomposition and dynamic tracking of the ventricular region of interest are used to extract information regarding the myocardial segmental motion. The proposed method was validated using simulation images and 50 clinical cases (25 patients and 25 healthy volunteers) for myocardial motion analysis. RESULTS: The results demonstrated that the proposed method could track the motion information of myocardial segments well and reduce the estimation errors of optical flow caused due to the use of low-quality echocardiogram images. CONCLUSIONS: The proposed method improves the accuracy of motion estimation for the cardiac ventricular wall. BioMed Central 2023-07-05 /pmc/articles/PMC10324115/ /pubmed/37407909 http://dx.doi.org/10.1186/s12880-023-01040-3 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Liu, Shanna Zhang, Hao Li, Chang Dai, Weifang Wu, Jinyu Wu, Yuanyuan Su, Wenwen Xia, Bin Zhou, Jiayu Shen, Yuqiang Zhu, Xinjian A method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram |
title | A method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram |
title_full | A method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram |
title_fullStr | A method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram |
title_full_unstemmed | A method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram |
title_short | A method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram |
title_sort | method of motion estimation of segmental ventricular wall with tracking of ultrasonic echocardiogram |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10324115/ https://www.ncbi.nlm.nih.gov/pubmed/37407909 http://dx.doi.org/10.1186/s12880-023-01040-3 |
work_keys_str_mv | AT liushanna amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT zhanghao amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT lichang amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT daiweifang amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT wujinyu amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT wuyuanyuan amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT suwenwen amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT xiabin amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT zhoujiayu amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT shenyuqiang amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT zhuxinjian amethodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT liushanna methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT zhanghao methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT lichang methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT daiweifang methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT wujinyu methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT wuyuanyuan methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT suwenwen methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT xiabin methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT zhoujiayu methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT shenyuqiang methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram AT zhuxinjian methodofmotionestimationofsegmentalventricularwallwithtrackingofultrasonicechocardiogram |