Performance, Test-retest Reliability, and Measurement Error of the Upper Limb Seated Shot Put Test According to Different Positions of Execution

BACKGROUND: The unilateral Seated Shot-Put Test (USSPT) is an easy to apply, inexpensive tool that can be used to assess shoulder performance unilaterally. Two different positions of execution have been described in previous studies, however, differences regarding reference values and psychometric p...

Descripción completa

Detalles Bibliográficos
Autores principales: Tagliarini, Gustavo O, Junior, José R. de S, Barbosa, Glauber M, P, Secchi, Leonardo L B
Formato: Online Artículo Texto
Lenguaje:English
Publicado: NASMI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10324283/
https://www.ncbi.nlm.nih.gov/pubmed/37425121
http://dx.doi.org/10.26603/001c.75227
_version_ 1785069118998708224
author Tagliarini, Gustavo O
Junior, José R. de S
Barbosa, Glauber M, P
Secchi, Leonardo L B
author_facet Tagliarini, Gustavo O
Junior, José R. de S
Barbosa, Glauber M, P
Secchi, Leonardo L B
author_sort Tagliarini, Gustavo O
collection PubMed
description BACKGROUND: The unilateral Seated Shot-Put Test (USSPT) is an easy to apply, inexpensive tool that can be used to assess shoulder performance unilaterally. Two different positions of execution have been described in previous studies, however, differences regarding reference values and psychometric properties were not assessed. PURPOSE: To investigate the performance, test-retest reliability and measurement error of the USSPT according to different positions of execution (floor versus chair) in overhead athletes. The hypothesis was that both positions would present similar values, good to excellent test-retest reliability and clinically acceptable measures. STUDY DESIGN: Test-retest reliability. METHODS: Forty-four overhead athletes performed the USSPT on the floor (USSPT-F) and on a chair (USSPT-C). Normative values were established according to gender, age, and dominance. Test-retest reliability was determined using Intraclass Correlation Coefficient and measurement error through Standard Error of Measurement, Smallest Detectable Change, as well as Bland and Altman plots. RESULTS: Reference values for both positions were provided. Women performed better on the USSPT-C than USSPT-F. Excellent test-retest reliability 0.97 (0.89 – 0.99) for dominant side and 0.95 (0.80 – 0.98) for non-dominant side was found for the USSPT-F. Moderate to excellent reliability 0.91 (0.67 – 0.98) for dominant side and 0.74 (0.01 – 0.93) for non-dominant side was found for the USSPT-C. Presence of systematic error (14.76 cm) was found only for USSPT-C dominant (p=0.011). CONCLUSION: Differences were found only for women with better performance on the USSPT-C. The USSPT-F presented higher reliability values. Both tests presented clinically acceptable measures. Presence of systematic error was found only in the USSPT-C. LEVEL OF EVIDENCE: 3
format Online
Article
Text
id pubmed-10324283
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher NASMI
record_format MEDLINE/PubMed
spelling pubmed-103242832023-07-07 Performance, Test-retest Reliability, and Measurement Error of the Upper Limb Seated Shot Put Test According to Different Positions of Execution Tagliarini, Gustavo O Junior, José R. de S Barbosa, Glauber M, P Secchi, Leonardo L B Int J Sports Phys Ther Original Research BACKGROUND: The unilateral Seated Shot-Put Test (USSPT) is an easy to apply, inexpensive tool that can be used to assess shoulder performance unilaterally. Two different positions of execution have been described in previous studies, however, differences regarding reference values and psychometric properties were not assessed. PURPOSE: To investigate the performance, test-retest reliability and measurement error of the USSPT according to different positions of execution (floor versus chair) in overhead athletes. The hypothesis was that both positions would present similar values, good to excellent test-retest reliability and clinically acceptable measures. STUDY DESIGN: Test-retest reliability. METHODS: Forty-four overhead athletes performed the USSPT on the floor (USSPT-F) and on a chair (USSPT-C). Normative values were established according to gender, age, and dominance. Test-retest reliability was determined using Intraclass Correlation Coefficient and measurement error through Standard Error of Measurement, Smallest Detectable Change, as well as Bland and Altman plots. RESULTS: Reference values for both positions were provided. Women performed better on the USSPT-C than USSPT-F. Excellent test-retest reliability 0.97 (0.89 – 0.99) for dominant side and 0.95 (0.80 – 0.98) for non-dominant side was found for the USSPT-F. Moderate to excellent reliability 0.91 (0.67 – 0.98) for dominant side and 0.74 (0.01 – 0.93) for non-dominant side was found for the USSPT-C. Presence of systematic error (14.76 cm) was found only for USSPT-C dominant (p=0.011). CONCLUSION: Differences were found only for women with better performance on the USSPT-C. The USSPT-F presented higher reliability values. Both tests presented clinically acceptable measures. Presence of systematic error was found only in the USSPT-C. LEVEL OF EVIDENCE: 3 NASMI 2023-06-01 /pmc/articles/PMC10324283/ /pubmed/37425121 http://dx.doi.org/10.26603/001c.75227 Text en https://creativecommons.org/licenses/by-nc/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (4.0) (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Original Research
Tagliarini, Gustavo O
Junior, José R. de S
Barbosa, Glauber M, P
Secchi, Leonardo L B
Performance, Test-retest Reliability, and Measurement Error of the Upper Limb Seated Shot Put Test According to Different Positions of Execution
title Performance, Test-retest Reliability, and Measurement Error of the Upper Limb Seated Shot Put Test According to Different Positions of Execution
title_full Performance, Test-retest Reliability, and Measurement Error of the Upper Limb Seated Shot Put Test According to Different Positions of Execution
title_fullStr Performance, Test-retest Reliability, and Measurement Error of the Upper Limb Seated Shot Put Test According to Different Positions of Execution
title_full_unstemmed Performance, Test-retest Reliability, and Measurement Error of the Upper Limb Seated Shot Put Test According to Different Positions of Execution
title_short Performance, Test-retest Reliability, and Measurement Error of the Upper Limb Seated Shot Put Test According to Different Positions of Execution
title_sort performance, test-retest reliability, and measurement error of the upper limb seated shot put test according to different positions of execution
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10324283/
https://www.ncbi.nlm.nih.gov/pubmed/37425121
http://dx.doi.org/10.26603/001c.75227
work_keys_str_mv AT tagliarinigustavoo performancetestretestreliabilityandmeasurementerroroftheupperlimbseatedshotputtestaccordingtodifferentpositionsofexecution
AT juniorjoserdes performancetestretestreliabilityandmeasurementerroroftheupperlimbseatedshotputtestaccordingtodifferentpositionsofexecution
AT barbosaglaubermp performancetestretestreliabilityandmeasurementerroroftheupperlimbseatedshotputtestaccordingtodifferentpositionsofexecution
AT secchileonardolb performancetestretestreliabilityandmeasurementerroroftheupperlimbseatedshotputtestaccordingtodifferentpositionsofexecution