Cargando…

Photon-Counting Computed Tomography (PC-CT) of the spine: impact on diagnostic confidence and radiation dose

OBJECTIVES: Computed tomography (CT) is employed to evaluate surgical outcome after spinal interventions. Here, we investigate the potential of multispectral photon-counting computed tomography (PC-CT) on image quality, diagnostic confidence, and radiation dose compared to an energy-integrating CT (...

Descripción completa

Detalles Bibliográficos
Autores principales: Rau, Alexander, Straehle, Jakob, Stein, Thomas, Diallo, Thierno, Rau, Stephan, Faby, Sebastian, Nikolaou, Konstantin, Schoenberg, Stefan O., Overhoff, Daniel, Beck, Jürgen, Urbach, Horst, Klingler, Jan-Helge, Bamberg, Fabian, Weiss, Jakob
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10326119/
https://www.ncbi.nlm.nih.gov/pubmed/36890304
http://dx.doi.org/10.1007/s00330-023-09511-5
Descripción
Sumario:OBJECTIVES: Computed tomography (CT) is employed to evaluate surgical outcome after spinal interventions. Here, we investigate the potential of multispectral photon-counting computed tomography (PC-CT) on image quality, diagnostic confidence, and radiation dose compared to an energy-integrating CT (EID-CT). METHODS: In this prospective study, 32 patients underwent PC-CT of the spine. Data was reconstructed in two ways: (1) standard bone kernel with 65-keV (PC-CT(std)) and (2) 130-keV monoenergetic images (PC-CT(130 keV)). Prior EID-CT was available for 17 patients; for the remaining 15, an age–, sex–, and body mass index–matched EID-CT cohort was identified. Image quality (5-point Likert scales on overall, sharpness, artifacts, noise, diagnostic confidence) of PC-CT(std) and EID-CT was assessed by four radiologists independently. If metallic implants were present (n = 10), PC-CT(std) and PC-CT(130 keV) images were again assessed by 5-point Likert scales by the same radiologists. Hounsfield units (HU) were measured within metallic artifact and compared between PC-CT(std) and PC-CT(130 keV). Finally, the radiation dose (CTDI(vol)) was evaluated. RESULTS: Sharpness was rated significantly higher (p = 0.009) and noise significantly lower (p < 0.001) in PC-CTstd vs. EID-CT. In the subset of patients with metallic implants, reading scores for PC-CT(130 keV) revealed superior ratings vs. PC-CT(std) for image quality, artifacts, noise, and diagnostic confidence (all p < 0.001) accompanied by a significant increase of HU values within the artifact (p < 0.001). Radiation dose was significantly lower for PC-CT vs. EID-CT (mean CTDI(vol): 8.83 vs. 15.7 mGy; p < 0.001). CONCLUSIONS: PC-CT of the spine with high-kiloelectronvolt reconstructions provides sharper images, higher diagnostic confidence, and lower radiation dose in patients with metallic implants. KEY POINTS: • Compared to energy-integrating CT, photon-counting CT of the spine had significantly higher sharpness and lower image noise while radiation dose was reduced by 45%. • In patients with metallic implants, virtual monochromatic photon-counting images at 130 keV were superior to standard reconstruction at 65 keV in terms of image quality, artifacts, noise, and diagnostic confidence.