Cargando…
CenTauR: Toward a universal scale and masks for standardizing tau imaging studies
INTRODUCTION: Recently, an increasing number of tau tracers have become available. There is a need to standardize quantitative tau measures across tracers, supporting a universal scale. We developed several cortical tau masks and applied them to generate a tau imaging universal scale. METHOD: One th...
Autores principales: | , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10326476/ https://www.ncbi.nlm.nih.gov/pubmed/37424964 http://dx.doi.org/10.1002/dad2.12454 |
_version_ | 1785069436350234624 |
---|---|
author | Villemagne, Victor L. Leuzy, Antoine Bohorquez, Sandra Sanabria Bullich, Santiago Shimada, Hitoshi Rowe, Christopher C. Bourgeat, Pierrick Lopresti, Brian Huang, Kun Krishnadas, Natasha Fripp, Jurgen Takado, Yuhei Gogola, Alexandra Minhas, Davneet Weimer, Robby Higuchi, Makoto Stephens, Andrew Hansson, Oskar Doré, Vincent |
author_facet | Villemagne, Victor L. Leuzy, Antoine Bohorquez, Sandra Sanabria Bullich, Santiago Shimada, Hitoshi Rowe, Christopher C. Bourgeat, Pierrick Lopresti, Brian Huang, Kun Krishnadas, Natasha Fripp, Jurgen Takado, Yuhei Gogola, Alexandra Minhas, Davneet Weimer, Robby Higuchi, Makoto Stephens, Andrew Hansson, Oskar Doré, Vincent |
author_sort | Villemagne, Victor L. |
collection | PubMed |
description | INTRODUCTION: Recently, an increasing number of tau tracers have become available. There is a need to standardize quantitative tau measures across tracers, supporting a universal scale. We developed several cortical tau masks and applied them to generate a tau imaging universal scale. METHOD: One thousand forty‐five participants underwent tau scans with either (18)F‐flortaucipir, (18)F‐MK6240, (18)F‐PI2620, (18)F‐PM‐PBB3, (18)F‐GTP1, or (18)F‐RO948. The universal mask was generated from cognitively unimpaired amyloid beta (Aβ)− subjects and Alzheimer's disease (AD) patients with Aβ+. Four additional regional cortical masks were defined within the constraints of the universal mask. A universal scale, the CenTauR(z), was constructed. RESULTS: None of the regions known to display off‐target signal were included in the masks. The CenTauR(z) allows robust discrimination between low and high levels of tau deposits. DISCUSSION: We constructed several tau‐specific cortical masks for the AD continuum and a universal standard scale designed to capture the location and degree of abnormality that can be applied across tracers and across centers. The masks are freely available at https://www.gaain.org/centaur‐project. |
format | Online Article Text |
id | pubmed-10326476 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-103264762023-07-08 CenTauR: Toward a universal scale and masks for standardizing tau imaging studies Villemagne, Victor L. Leuzy, Antoine Bohorquez, Sandra Sanabria Bullich, Santiago Shimada, Hitoshi Rowe, Christopher C. Bourgeat, Pierrick Lopresti, Brian Huang, Kun Krishnadas, Natasha Fripp, Jurgen Takado, Yuhei Gogola, Alexandra Minhas, Davneet Weimer, Robby Higuchi, Makoto Stephens, Andrew Hansson, Oskar Doré, Vincent Alzheimers Dement (Amst) Research Articles INTRODUCTION: Recently, an increasing number of tau tracers have become available. There is a need to standardize quantitative tau measures across tracers, supporting a universal scale. We developed several cortical tau masks and applied them to generate a tau imaging universal scale. METHOD: One thousand forty‐five participants underwent tau scans with either (18)F‐flortaucipir, (18)F‐MK6240, (18)F‐PI2620, (18)F‐PM‐PBB3, (18)F‐GTP1, or (18)F‐RO948. The universal mask was generated from cognitively unimpaired amyloid beta (Aβ)− subjects and Alzheimer's disease (AD) patients with Aβ+. Four additional regional cortical masks were defined within the constraints of the universal mask. A universal scale, the CenTauR(z), was constructed. RESULTS: None of the regions known to display off‐target signal were included in the masks. The CenTauR(z) allows robust discrimination between low and high levels of tau deposits. DISCUSSION: We constructed several tau‐specific cortical masks for the AD continuum and a universal standard scale designed to capture the location and degree of abnormality that can be applied across tracers and across centers. The masks are freely available at https://www.gaain.org/centaur‐project. John Wiley and Sons Inc. 2023-07-07 /pmc/articles/PMC10326476/ /pubmed/37424964 http://dx.doi.org/10.1002/dad2.12454 Text en © 2023 CSIRO and The Authors. Alzheimer's & Dementia: Diagnosis, Assessment & Disease Monitoring published by Wiley Periodicals LLC on behalf of Alzheimer's Association. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Articles Villemagne, Victor L. Leuzy, Antoine Bohorquez, Sandra Sanabria Bullich, Santiago Shimada, Hitoshi Rowe, Christopher C. Bourgeat, Pierrick Lopresti, Brian Huang, Kun Krishnadas, Natasha Fripp, Jurgen Takado, Yuhei Gogola, Alexandra Minhas, Davneet Weimer, Robby Higuchi, Makoto Stephens, Andrew Hansson, Oskar Doré, Vincent CenTauR: Toward a universal scale and masks for standardizing tau imaging studies |
title | CenTauR: Toward a universal scale and masks for standardizing tau imaging studies |
title_full | CenTauR: Toward a universal scale and masks for standardizing tau imaging studies |
title_fullStr | CenTauR: Toward a universal scale and masks for standardizing tau imaging studies |
title_full_unstemmed | CenTauR: Toward a universal scale and masks for standardizing tau imaging studies |
title_short | CenTauR: Toward a universal scale and masks for standardizing tau imaging studies |
title_sort | centaur: toward a universal scale and masks for standardizing tau imaging studies |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10326476/ https://www.ncbi.nlm.nih.gov/pubmed/37424964 http://dx.doi.org/10.1002/dad2.12454 |
work_keys_str_mv | AT villemagnevictorl centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT leuzyantoine centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT bohorquezsandrasanabria centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT bullichsantiago centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT shimadahitoshi centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT rowechristopherc centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT bourgeatpierrick centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT loprestibrian centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT huangkun centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT krishnadasnatasha centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT frippjurgen centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT takadoyuhei centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT gogolaalexandra centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT minhasdavneet centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT weimerrobby centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT higuchimakoto centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT stephensandrew centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT hanssonoskar centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT dorevincent centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies AT centaurtowardauniversalscaleandmasksforstandardizingtauimagingstudies |