Cargando…
Clinical Value of Combined Detection of Serum sTim-3 and CEA or CA19-9 for Postoperative Recurrence of Colorectal Cancer Diagnosis
PURPOSE: The present study aimed to evaluate the clinical value of Combined Detection of serum soluble T-cell immunoglobulin 3 (sTim-3) with carcinoembryonic antigen (CEA) or glycotype antigen 19–9 (CA19-9) for Postoperative Recurrence of Colorectal Cancer (CRC) Diagnosis. PATIENTS AND METHODS: The...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10328395/ https://www.ncbi.nlm.nih.gov/pubmed/37426393 http://dx.doi.org/10.2147/CMAR.S407930 |
Sumario: | PURPOSE: The present study aimed to evaluate the clinical value of Combined Detection of serum soluble T-cell immunoglobulin 3 (sTim-3) with carcinoembryonic antigen (CEA) or glycotype antigen 19–9 (CA19-9) for Postoperative Recurrence of Colorectal Cancer (CRC) Diagnosis. PATIENTS AND METHODS: The serum sTim-3 was measured by highly sensitivity TRFIA, and serum CEA and CA19-9 were obtained through the collection of clinical data. Quantitative detection of serum sTim-3, CEA, CA19-9 in 90 patients after the CRC surgery (52 postoperative recurrence and 38 no-postoperative recurrence), 21 patients with colorectal benign tumors, and 67 healthy controls. To analyze the clinical diagnostic value of combined detection of sTim-3 with CEA or CA19-9 to test whether patients have recurrence after CRC surgery. RESULTS: The sTim-3 (15.94±11.24ng/mL) in patients after CRC surgery was significantly higher than in healthy controls (8.95±3.34ng/mL) and colorectal benign tumors (8.39±2.28ng/mL) (P < 0.05), and sTim-3 (20.33±13.04ng/mL) in CRC postoperative recurrent group was significantly higher than in the group without recurrence after CRC surgery (9.94±2.36ng/mL) (P < 0.05). In terms of detecting postoperative recurrence after CRC surgery, combined detection of sTim-3 and CEA (AUC: 0.819, sensitivity: 80.77%, specificity: 65.79%), sTim-3 and CA19-9 test (AUC: 0.813, sensitivity: 69.23%, specificity: 97.30%) was significantly better than the CEA single test (AUC: 0.547, sensitivity: 63.16%, specificity: 48.08%) and CA19-9 single test (AUC: 0.675 sensitivity: 65.38%, specificity: 67.57%), Delong test P < 0.05. CONCLUSION: The efficacy of CEA and CA19-9 single test was not optimal, and the combination of sTim-3 in serum could significantly improve the sensitivity and specificity of detecting patient recurrence after CRC surgery. |
---|