Cargando…

The use of bovine-derived hydroxyapatite xenograft for defect filling in opening-wedge high tibial osteotomy

High tibial osteotomy is a reliable procedure for the correction of knee varus deformity. An opening-wedge high tibial osteotomy (OW-HTO) is the most popular technique. The results of the bone defect after opening the wedge needed special treatment to ensure bone healing. This study aims to evaluate...

Descripción completa

Detalles Bibliográficos
Autores principales: Santoso, Asep, Utomo, Pamudji, Mahyudin, Ferdiansyah, Utomo, Dwikora N., Budhiparama, Nicolaas C., Anwar, Iwan B., Sibarani, Tangkas, Warman, Fanny I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10328623/
https://www.ncbi.nlm.nih.gov/pubmed/37427156
http://dx.doi.org/10.1097/MS9.0000000000000972
_version_ 1785069838630125568
author Santoso, Asep
Utomo, Pamudji
Mahyudin, Ferdiansyah
Utomo, Dwikora N.
Budhiparama, Nicolaas C.
Anwar, Iwan B.
Sibarani, Tangkas
Warman, Fanny I.
author_facet Santoso, Asep
Utomo, Pamudji
Mahyudin, Ferdiansyah
Utomo, Dwikora N.
Budhiparama, Nicolaas C.
Anwar, Iwan B.
Sibarani, Tangkas
Warman, Fanny I.
author_sort Santoso, Asep
collection PubMed
description High tibial osteotomy is a reliable procedure for the correction of knee varus deformity. An opening-wedge high tibial osteotomy (OW-HTO) is the most popular technique. The results of the bone defect after opening the wedge needed special treatment to ensure bone healing. This study aims to evaluate the use of bovine-derived hydroxyapatite graft for defect filling after OW-HTO. METHODS: A retrospective study was performed on all patients who received OW-HTO at Prof. Dr R. Soeharso Orthopaedic Hospital from November 2019 to December 2022. A total of 21 patients (24 knees) were included in this study. Clinical dan radiological evaluation was performed on all patients preoperative and postoperatively. The mean of the follow-up period was 12.6 months with a minimum of 4 months follow-up. RESULTS: Primary medial uni-compartment knee osteoarthritis was the most common diagnosis, with 17 of 24 cases (70.8%). Mechanical axis deviation was changed from 31 mm medial deviation (range: 8–52 mm) to 0.45 mm medial deviation (range: 13 - (-8) mm). The anatomic tibiofemoral angle was corrected from a preoperative mean of 4.7(°) of varus to a mean of 5.8(°) of valgus postoperatively. Bone defect height was mean 15.9 mm with a range of 10–23 mm. Bone defect width was mean 46.7 mm (range: 34–60 mm). Hydroxyapatite graft integration with the host bone was found in all patients during the final follow-up period. CONCLUSIONS: Bovine-derived hydroxyapatite graft is a safe and effective material for bone defect filling in OW-HTO procedures with a high bone union rate.
format Online
Article
Text
id pubmed-10328623
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-103286232023-07-08 The use of bovine-derived hydroxyapatite xenograft for defect filling in opening-wedge high tibial osteotomy Santoso, Asep Utomo, Pamudji Mahyudin, Ferdiansyah Utomo, Dwikora N. Budhiparama, Nicolaas C. Anwar, Iwan B. Sibarani, Tangkas Warman, Fanny I. Ann Med Surg (Lond) Original Research High tibial osteotomy is a reliable procedure for the correction of knee varus deformity. An opening-wedge high tibial osteotomy (OW-HTO) is the most popular technique. The results of the bone defect after opening the wedge needed special treatment to ensure bone healing. This study aims to evaluate the use of bovine-derived hydroxyapatite graft for defect filling after OW-HTO. METHODS: A retrospective study was performed on all patients who received OW-HTO at Prof. Dr R. Soeharso Orthopaedic Hospital from November 2019 to December 2022. A total of 21 patients (24 knees) were included in this study. Clinical dan radiological evaluation was performed on all patients preoperative and postoperatively. The mean of the follow-up period was 12.6 months with a minimum of 4 months follow-up. RESULTS: Primary medial uni-compartment knee osteoarthritis was the most common diagnosis, with 17 of 24 cases (70.8%). Mechanical axis deviation was changed from 31 mm medial deviation (range: 8–52 mm) to 0.45 mm medial deviation (range: 13 - (-8) mm). The anatomic tibiofemoral angle was corrected from a preoperative mean of 4.7(°) of varus to a mean of 5.8(°) of valgus postoperatively. Bone defect height was mean 15.9 mm with a range of 10–23 mm. Bone defect width was mean 46.7 mm (range: 34–60 mm). Hydroxyapatite graft integration with the host bone was found in all patients during the final follow-up period. CONCLUSIONS: Bovine-derived hydroxyapatite graft is a safe and effective material for bone defect filling in OW-HTO procedures with a high bone union rate. Lippincott Williams & Wilkins 2023-06-17 /pmc/articles/PMC10328623/ /pubmed/37427156 http://dx.doi.org/10.1097/MS9.0000000000000972 Text en Copyright © 2023 The Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nd/4.0/This is an open access article distributed under the Creative Commons Attribution-NoDerivatives License 4.0 (https://creativecommons.org/licenses/by-nd/4.0/) , which allows for redistribution, commercial and non-commercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0/ (https://creativecommons.org/licenses/by-nd/4.0/)
spellingShingle Original Research
Santoso, Asep
Utomo, Pamudji
Mahyudin, Ferdiansyah
Utomo, Dwikora N.
Budhiparama, Nicolaas C.
Anwar, Iwan B.
Sibarani, Tangkas
Warman, Fanny I.
The use of bovine-derived hydroxyapatite xenograft for defect filling in opening-wedge high tibial osteotomy
title The use of bovine-derived hydroxyapatite xenograft for defect filling in opening-wedge high tibial osteotomy
title_full The use of bovine-derived hydroxyapatite xenograft for defect filling in opening-wedge high tibial osteotomy
title_fullStr The use of bovine-derived hydroxyapatite xenograft for defect filling in opening-wedge high tibial osteotomy
title_full_unstemmed The use of bovine-derived hydroxyapatite xenograft for defect filling in opening-wedge high tibial osteotomy
title_short The use of bovine-derived hydroxyapatite xenograft for defect filling in opening-wedge high tibial osteotomy
title_sort use of bovine-derived hydroxyapatite xenograft for defect filling in opening-wedge high tibial osteotomy
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10328623/
https://www.ncbi.nlm.nih.gov/pubmed/37427156
http://dx.doi.org/10.1097/MS9.0000000000000972
work_keys_str_mv AT santosoasep theuseofbovinederivedhydroxyapatitexenograftfordefectfillinginopeningwedgehightibialosteotomy
AT utomopamudji theuseofbovinederivedhydroxyapatitexenograftfordefectfillinginopeningwedgehightibialosteotomy
AT mahyudinferdiansyah theuseofbovinederivedhydroxyapatitexenograftfordefectfillinginopeningwedgehightibialosteotomy
AT utomodwikoran theuseofbovinederivedhydroxyapatitexenograftfordefectfillinginopeningwedgehightibialosteotomy
AT budhiparamanicolaasc theuseofbovinederivedhydroxyapatitexenograftfordefectfillinginopeningwedgehightibialosteotomy
AT anwariwanb theuseofbovinederivedhydroxyapatitexenograftfordefectfillinginopeningwedgehightibialosteotomy
AT sibaranitangkas theuseofbovinederivedhydroxyapatitexenograftfordefectfillinginopeningwedgehightibialosteotomy
AT warmanfannyi theuseofbovinederivedhydroxyapatitexenograftfordefectfillinginopeningwedgehightibialosteotomy
AT santosoasep useofbovinederivedhydroxyapatitexenograftfordefectfillinginopeningwedgehightibialosteotomy
AT utomopamudji useofbovinederivedhydroxyapatitexenograftfordefectfillinginopeningwedgehightibialosteotomy
AT mahyudinferdiansyah useofbovinederivedhydroxyapatitexenograftfordefectfillinginopeningwedgehightibialosteotomy
AT utomodwikoran useofbovinederivedhydroxyapatitexenograftfordefectfillinginopeningwedgehightibialosteotomy
AT budhiparamanicolaasc useofbovinederivedhydroxyapatitexenograftfordefectfillinginopeningwedgehightibialosteotomy
AT anwariwanb useofbovinederivedhydroxyapatitexenograftfordefectfillinginopeningwedgehightibialosteotomy
AT sibaranitangkas useofbovinederivedhydroxyapatitexenograftfordefectfillinginopeningwedgehightibialosteotomy
AT warmanfannyi useofbovinederivedhydroxyapatitexenograftfordefectfillinginopeningwedgehightibialosteotomy