Cargando…

A novel method of assessment of BMD using CBCT for implant placement: A retrospective study

Nowadays, dental implant evolves as an alternative treatment modality for oral rehabilitation. The success of dental implants is largely dependent on bone density; Cone-beam computed tomography (CBCT) is a well-known modus operandi for the volumetric measurement of bone mineral density (BMD), which...

Descripción completa

Detalles Bibliográficos
Autor principal: AlQahtani, Saad Mohammed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10328703/
https://www.ncbi.nlm.nih.gov/pubmed/37417616
http://dx.doi.org/10.1097/MD.0000000000034203
_version_ 1785069858546778112
author AlQahtani, Saad Mohammed
author_facet AlQahtani, Saad Mohammed
author_sort AlQahtani, Saad Mohammed
collection PubMed
description Nowadays, dental implant evolves as an alternative treatment modality for oral rehabilitation. The success of dental implants is largely dependent on bone density; Cone-beam computed tomography (CBCT) is a well-known modus operandi for the volumetric measurement of bone mineral density (BMD), which measures Grayscale values on 3-D images. This study was conducted with the aim to analyze bone density with CBCT and also test its reliability and reproducibility using Galileos Sirona CBCT Viewer Software and Philips digital imaging and communications in medicine (DICOM) Viewer. A total of 75, CBCT images were obtained from the Department of Oral Radiology, retrospectively, and, BMD in Hounsfield units (HUs) was evaluated in a standardized implant area superimposed on the images. Bone density was also calculated by 2 different independent observers. The estimation of sample size was achieved to attain a power of 90% with 0.5 alpha error and 0.2 effect size as per a previous study. Statistical analysis was performed by statistical package for the social sciences version 22.0; data were presented as mean and standard deviation and Kappa correlation test was applied to check the reproducibility of values. The mean and standard deviation of grayscale values and HUs attained from the interdental area of front teeth were 1837 (288.76) and 270 (125.4), respectively, with a conversion factor of 6.8. Whereas the mean and standard deviation of grayscale values and HUs acquired from posterior interdental spaces were 2880 (489.99) and 640 (204.6), respectively, with a conversion factor of 4.5. To verify the reproducibility Kappa correlation test was applied, which showed correlation values of 0.68 and 0.79. The conversion or exchange factors for grayscale values to HUs determined at the frontal, posterior interdental space area and from the highly radio-opaque area were exceedingly reproducible and consistent. Hence, CBCT can be used as one of the valuable techniques in the estimation of bone density.
format Online
Article
Text
id pubmed-10328703
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-103287032023-07-08 A novel method of assessment of BMD using CBCT for implant placement: A retrospective study AlQahtani, Saad Mohammed Medicine (Baltimore) 5900 Nowadays, dental implant evolves as an alternative treatment modality for oral rehabilitation. The success of dental implants is largely dependent on bone density; Cone-beam computed tomography (CBCT) is a well-known modus operandi for the volumetric measurement of bone mineral density (BMD), which measures Grayscale values on 3-D images. This study was conducted with the aim to analyze bone density with CBCT and also test its reliability and reproducibility using Galileos Sirona CBCT Viewer Software and Philips digital imaging and communications in medicine (DICOM) Viewer. A total of 75, CBCT images were obtained from the Department of Oral Radiology, retrospectively, and, BMD in Hounsfield units (HUs) was evaluated in a standardized implant area superimposed on the images. Bone density was also calculated by 2 different independent observers. The estimation of sample size was achieved to attain a power of 90% with 0.5 alpha error and 0.2 effect size as per a previous study. Statistical analysis was performed by statistical package for the social sciences version 22.0; data were presented as mean and standard deviation and Kappa correlation test was applied to check the reproducibility of values. The mean and standard deviation of grayscale values and HUs attained from the interdental area of front teeth were 1837 (288.76) and 270 (125.4), respectively, with a conversion factor of 6.8. Whereas the mean and standard deviation of grayscale values and HUs acquired from posterior interdental spaces were 2880 (489.99) and 640 (204.6), respectively, with a conversion factor of 4.5. To verify the reproducibility Kappa correlation test was applied, which showed correlation values of 0.68 and 0.79. The conversion or exchange factors for grayscale values to HUs determined at the frontal, posterior interdental space area and from the highly radio-opaque area were exceedingly reproducible and consistent. Hence, CBCT can be used as one of the valuable techniques in the estimation of bone density. Lippincott Williams & Wilkins 2023-07-07 /pmc/articles/PMC10328703/ /pubmed/37417616 http://dx.doi.org/10.1097/MD.0000000000034203 Text en Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC) (https://creativecommons.org/licenses/by-nc/4.0/) , where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal.
spellingShingle 5900
AlQahtani, Saad Mohammed
A novel method of assessment of BMD using CBCT for implant placement: A retrospective study
title A novel method of assessment of BMD using CBCT for implant placement: A retrospective study
title_full A novel method of assessment of BMD using CBCT for implant placement: A retrospective study
title_fullStr A novel method of assessment of BMD using CBCT for implant placement: A retrospective study
title_full_unstemmed A novel method of assessment of BMD using CBCT for implant placement: A retrospective study
title_short A novel method of assessment of BMD using CBCT for implant placement: A retrospective study
title_sort novel method of assessment of bmd using cbct for implant placement: a retrospective study
topic 5900
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10328703/
https://www.ncbi.nlm.nih.gov/pubmed/37417616
http://dx.doi.org/10.1097/MD.0000000000034203
work_keys_str_mv AT alqahtanisaadmohammed anovelmethodofassessmentofbmdusingcbctforimplantplacementaretrospectivestudy
AT alqahtanisaadmohammed novelmethodofassessmentofbmdusingcbctforimplantplacementaretrospectivestudy