Cargando…

Coherent diffractive imaging of proteins and viral capsids: simulating MS SPIDOC

MS SPIDOC is a novel sample delivery system designed for single (isolated) particle imaging at X-ray Free-Electron Lasers that is adaptable towards most large-scale facility beamlines. Biological samples can range from small proteins to MDa particles. Following nano-electrospray ionization, ionic sa...

Descripción completa

Detalles Bibliográficos
Autores principales: Kierspel, Thomas, Kadek, Alan, Barran, Perdita, Bellina, Bruno, Bijedic, Adi, Brodmerkel, Maxim N., Commandeur, Jan, Caleman, Carl, Damjanović, Tomislav, Dawod, Ibrahim, De Santis, Emiliano, Lekkas, Alexandros, Lorenzen, Kristina, Morillo, Luis López, Mandl, Thomas, Marklund, Erik G., Papanastasiou, Dimitris, Ramakers, Lennart A. I., Schweikhard, Lutz, Simke, Florian, Sinelnikova, Anna, Smyrnakis, Athanasios, Timneanu, Nicusor, Uetrecht, Charlotte
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10329076/
https://www.ncbi.nlm.nih.gov/pubmed/37014373
http://dx.doi.org/10.1007/s00216-023-04658-y
Descripción
Sumario:MS SPIDOC is a novel sample delivery system designed for single (isolated) particle imaging at X-ray Free-Electron Lasers that is adaptable towards most large-scale facility beamlines. Biological samples can range from small proteins to MDa particles. Following nano-electrospray ionization, ionic samples can be m/z-filtered and structurally separated before being oriented at the interaction zone. Here, we present the simulation package developed alongside this prototype. The first part describes how the front-to-end ion trajectory simulations have been conducted. Highlighted is a quadrant lens; a simple but efficient device that steers the ion beam within the vicinity of the strong DC orientation field in the interaction zone to ensure spatial overlap with the X-rays. The second part focuses on protein orientation and discusses its potential with respect to diffractive imaging methods. Last, coherent diffractive imaging of prototypical T = 1 and T = 3 norovirus capsids is shown. We use realistic experimental parameters from the SPB/SFX instrument at the European XFEL to demonstrate that low-resolution diffractive imaging data (q < 0.3 nm(−1)) can be collected with only a few X-ray pulses. Such low-resolution data are sufficient to distinguish between both symmetries of the capsids, allowing to probe low abundant species in a beam if MS SPIDOC is used as sample delivery.