Cargando…
Characteristics and aetiology of low‐temperature burns in Beijing of China
This study was designed to analyse the characteristics and aetiology of low‐temperature burns and explore the prevention and treatment strategies. In total, 206 patients hospitalised with low‐temperature burns in a major burn center in Beijing from 2017 to 2021 were included. There were 35–49 cases...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Blackwell Publishing Ltd
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10333022/ https://www.ncbi.nlm.nih.gov/pubmed/36708278 http://dx.doi.org/10.1111/iwj.14085 |
_version_ | 1785070564261494784 |
---|---|
author | Xie, Xiaoye Liu, Xinzhu Cai, Jianhua Zhang, Bohan Sun, Tianjun Luo, Peng An, Dai Deng, Yurong Shen, Chuan'an |
author_facet | Xie, Xiaoye Liu, Xinzhu Cai, Jianhua Zhang, Bohan Sun, Tianjun Luo, Peng An, Dai Deng, Yurong Shen, Chuan'an |
author_sort | Xie, Xiaoye |
collection | PubMed |
description | This study was designed to analyse the characteristics and aetiology of low‐temperature burns and explore the prevention and treatment strategies. In total, 206 patients hospitalised with low‐temperature burns in a major burn center in Beijing from 2017 to 2021 were included. There were 35–49 cases per year, with an average of 41 ± 4.5 cases. The prevalence of low‐temperature burns was higher in female than in male and are mainly resulted from two kinds of incidents: unintended burns from heat treatment (50.97%, 105/206) and improper use of heating devices to keep warm (43.69%, 90/206). Most cases occurred in autumn (33.01%, 68/206) and the least in spring (17.96%, 37/206); cases in summer (24.27%, 50/206) and winter (24.76%, 51/206) accounted for nearly a quadrant respectively. Low‐temperature burns in summer were mainly unintended burns from heat treatment (80%, 40/50), whereas in autumn were mainly resulted from improper use of heating devices to keep warm (55.88%, 38/68), the difference was statistically significant (χ (2) = 42.801, P < .001). Of all the cases, the burn size ranged from 0.2% to 5% TBSA, mostly less than 1% (85.92%, 177/206); third‐degree burns accounted for 98.54% (203/206). Patients admitted after 3 weeks post‐injury accounted for 42.23% (87/206). All patients were cured, and most of them were by surgeries (70.87%, 146/206). The results of the study show that low‐temperature burn injury features a predictable morbidity among different seasons, a higher prevalence in adult women and a frequent occurrence at home. The wounds of low‐temperature burns are often small in size but deep in depth, and can be easily misdiagnosed as superficial burns. However, most low‐temperature burn wounds require surgical treatment. The study also suggests that based on the characteristics and aetiology of low‐temperature burns, targeted prevention and treatment measures should be mapped out. |
format | Online Article Text |
id | pubmed-10333022 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Blackwell Publishing Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-103330222023-07-12 Characteristics and aetiology of low‐temperature burns in Beijing of China Xie, Xiaoye Liu, Xinzhu Cai, Jianhua Zhang, Bohan Sun, Tianjun Luo, Peng An, Dai Deng, Yurong Shen, Chuan'an Int Wound J Original Articles This study was designed to analyse the characteristics and aetiology of low‐temperature burns and explore the prevention and treatment strategies. In total, 206 patients hospitalised with low‐temperature burns in a major burn center in Beijing from 2017 to 2021 were included. There were 35–49 cases per year, with an average of 41 ± 4.5 cases. The prevalence of low‐temperature burns was higher in female than in male and are mainly resulted from two kinds of incidents: unintended burns from heat treatment (50.97%, 105/206) and improper use of heating devices to keep warm (43.69%, 90/206). Most cases occurred in autumn (33.01%, 68/206) and the least in spring (17.96%, 37/206); cases in summer (24.27%, 50/206) and winter (24.76%, 51/206) accounted for nearly a quadrant respectively. Low‐temperature burns in summer were mainly unintended burns from heat treatment (80%, 40/50), whereas in autumn were mainly resulted from improper use of heating devices to keep warm (55.88%, 38/68), the difference was statistically significant (χ (2) = 42.801, P < .001). Of all the cases, the burn size ranged from 0.2% to 5% TBSA, mostly less than 1% (85.92%, 177/206); third‐degree burns accounted for 98.54% (203/206). Patients admitted after 3 weeks post‐injury accounted for 42.23% (87/206). All patients were cured, and most of them were by surgeries (70.87%, 146/206). The results of the study show that low‐temperature burn injury features a predictable morbidity among different seasons, a higher prevalence in adult women and a frequent occurrence at home. The wounds of low‐temperature burns are often small in size but deep in depth, and can be easily misdiagnosed as superficial burns. However, most low‐temperature burn wounds require surgical treatment. The study also suggests that based on the characteristics and aetiology of low‐temperature burns, targeted prevention and treatment measures should be mapped out. Blackwell Publishing Ltd 2023-01-28 /pmc/articles/PMC10333022/ /pubmed/36708278 http://dx.doi.org/10.1111/iwj.14085 Text en © 2023 The Authors. International Wound Journal published by Medicalhelplines.com Inc (3M) and John Wiley & Sons Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Original Articles Xie, Xiaoye Liu, Xinzhu Cai, Jianhua Zhang, Bohan Sun, Tianjun Luo, Peng An, Dai Deng, Yurong Shen, Chuan'an Characteristics and aetiology of low‐temperature burns in Beijing of China |
title | Characteristics and aetiology of low‐temperature burns in Beijing of China |
title_full | Characteristics and aetiology of low‐temperature burns in Beijing of China |
title_fullStr | Characteristics and aetiology of low‐temperature burns in Beijing of China |
title_full_unstemmed | Characteristics and aetiology of low‐temperature burns in Beijing of China |
title_short | Characteristics and aetiology of low‐temperature burns in Beijing of China |
title_sort | characteristics and aetiology of low‐temperature burns in beijing of china |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10333022/ https://www.ncbi.nlm.nih.gov/pubmed/36708278 http://dx.doi.org/10.1111/iwj.14085 |
work_keys_str_mv | AT xiexiaoye characteristicsandaetiologyoflowtemperatureburnsinbeijingofchina AT liuxinzhu characteristicsandaetiologyoflowtemperatureburnsinbeijingofchina AT caijianhua characteristicsandaetiologyoflowtemperatureburnsinbeijingofchina AT zhangbohan characteristicsandaetiologyoflowtemperatureburnsinbeijingofchina AT suntianjun characteristicsandaetiologyoflowtemperatureburnsinbeijingofchina AT luopeng characteristicsandaetiologyoflowtemperatureburnsinbeijingofchina AT andai characteristicsandaetiologyoflowtemperatureburnsinbeijingofchina AT dengyurong characteristicsandaetiologyoflowtemperatureburnsinbeijingofchina AT shenchuanan characteristicsandaetiologyoflowtemperatureburnsinbeijingofchina |