Cargando…

Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems

PURPOSE: This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. MATERIALS AND METHODS: Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was...

Descripción completa

Detalles Bibliográficos
Autores principales: Bae, Eun-Bin, Cho, Won-Tak, Park, Do-Hyun, Hwang, Su-Hyun, Lee, So-Hyoun, Yun, Mi-Jung, Jeong, Chang-Mo, Huh, Jung-Bo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10333096/
https://www.ncbi.nlm.nih.gov/pubmed/37441720
http://dx.doi.org/10.4047/jap.2023.15.3.155
_version_ 1785070581755936768
author Bae, Eun-Bin
Cho, Won-Tak
Park, Do-Hyun
Hwang, Su-Hyun
Lee, So-Hyoun
Yun, Mi-Jung
Jeong, Chang-Mo
Huh, Jung-Bo
author_facet Bae, Eun-Bin
Cho, Won-Tak
Park, Do-Hyun
Hwang, Su-Hyun
Lee, So-Hyoun
Yun, Mi-Jung
Jeong, Chang-Mo
Huh, Jung-Bo
author_sort Bae, Eun-Bin
collection PubMed
description PURPOSE: This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. MATERIALS AND METHODS: Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was made through the cross-application of 3 different design software (EZIS VR, 3Shape Dental System, Exocad) with 3 different processing devices (Aegis HM, Trione Z, Motion 2). The marginal gap, absolute marginal discrepancy, internal gap(axial, line angle, occlusal) by a silicone replica technique were measured to compare the fit of the crown. The scanned inner and outer surfaces of the crowns were compared to CAD data using 3D metrology software to evaluate trueness. RESULTS: There were significant differences in the marginal gap, absolute marginal discrepancy, axial and line angle internal gap among the groups (P < .05) in the comparison of fit. There was no statistically significant difference among the groups in terms of occlusal internal gap. The trueness ranged from 36.19 to 43.78 µm but there was no statistically significant difference within the groups (P > .05). CONCLUSION: All 9 groups showed clinically acceptable level of marginal gaps ranging from 74.26 to 112.20 µm in terms of fit comparison. In the comparison of trueness, no significant difference within each group was spotted. Within the limitation of this study, open CAD-CAM systems used in this study can be assembled properly to fabricate zirconia crown.
format Online
Article
Text
id pubmed-10333096
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-103330962023-07-12 Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems Bae, Eun-Bin Cho, Won-Tak Park, Do-Hyun Hwang, Su-Hyun Lee, So-Hyoun Yun, Mi-Jung Jeong, Chang-Mo Huh, Jung-Bo J Adv Prosthodont Original Article PURPOSE: This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. MATERIALS AND METHODS: Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was made through the cross-application of 3 different design software (EZIS VR, 3Shape Dental System, Exocad) with 3 different processing devices (Aegis HM, Trione Z, Motion 2). The marginal gap, absolute marginal discrepancy, internal gap(axial, line angle, occlusal) by a silicone replica technique were measured to compare the fit of the crown. The scanned inner and outer surfaces of the crowns were compared to CAD data using 3D metrology software to evaluate trueness. RESULTS: There were significant differences in the marginal gap, absolute marginal discrepancy, axial and line angle internal gap among the groups (P < .05) in the comparison of fit. There was no statistically significant difference among the groups in terms of occlusal internal gap. The trueness ranged from 36.19 to 43.78 µm but there was no statistically significant difference within the groups (P > .05). CONCLUSION: All 9 groups showed clinically acceptable level of marginal gaps ranging from 74.26 to 112.20 µm in terms of fit comparison. In the comparison of trueness, no significant difference within each group was spotted. Within the limitation of this study, open CAD-CAM systems used in this study can be assembled properly to fabricate zirconia crown. The Korean Academy of Prosthodontics 2023-06 2023-06-28 /pmc/articles/PMC10333096/ /pubmed/37441720 http://dx.doi.org/10.4047/jap.2023.15.3.155 Text en © 2023 The Korean Academy of Prosthodontics https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Bae, Eun-Bin
Cho, Won-Tak
Park, Do-Hyun
Hwang, Su-Hyun
Lee, So-Hyoun
Yun, Mi-Jung
Jeong, Chang-Mo
Huh, Jung-Bo
Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems
title Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems
title_full Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems
title_fullStr Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems
title_full_unstemmed Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems
title_short Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems
title_sort comparison of fit and trueness of zirconia crowns fabricated by different combinations of open cad-cam systems
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10333096/
https://www.ncbi.nlm.nih.gov/pubmed/37441720
http://dx.doi.org/10.4047/jap.2023.15.3.155
work_keys_str_mv AT baeeunbin comparisonoffitandtruenessofzirconiacrownsfabricatedbydifferentcombinationsofopencadcamsystems
AT chowontak comparisonoffitandtruenessofzirconiacrownsfabricatedbydifferentcombinationsofopencadcamsystems
AT parkdohyun comparisonoffitandtruenessofzirconiacrownsfabricatedbydifferentcombinationsofopencadcamsystems
AT hwangsuhyun comparisonoffitandtruenessofzirconiacrownsfabricatedbydifferentcombinationsofopencadcamsystems
AT leesohyoun comparisonoffitandtruenessofzirconiacrownsfabricatedbydifferentcombinationsofopencadcamsystems
AT yunmijung comparisonoffitandtruenessofzirconiacrownsfabricatedbydifferentcombinationsofopencadcamsystems
AT jeongchangmo comparisonoffitandtruenessofzirconiacrownsfabricatedbydifferentcombinationsofopencadcamsystems
AT huhjungbo comparisonoffitandtruenessofzirconiacrownsfabricatedbydifferentcombinationsofopencadcamsystems