Cargando…
Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems
PURPOSE: This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. MATERIALS AND METHODS: Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10333096/ https://www.ncbi.nlm.nih.gov/pubmed/37441720 http://dx.doi.org/10.4047/jap.2023.15.3.155 |
_version_ | 1785070581755936768 |
---|---|
author | Bae, Eun-Bin Cho, Won-Tak Park, Do-Hyun Hwang, Su-Hyun Lee, So-Hyoun Yun, Mi-Jung Jeong, Chang-Mo Huh, Jung-Bo |
author_facet | Bae, Eun-Bin Cho, Won-Tak Park, Do-Hyun Hwang, Su-Hyun Lee, So-Hyoun Yun, Mi-Jung Jeong, Chang-Mo Huh, Jung-Bo |
author_sort | Bae, Eun-Bin |
collection | PubMed |
description | PURPOSE: This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. MATERIALS AND METHODS: Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was made through the cross-application of 3 different design software (EZIS VR, 3Shape Dental System, Exocad) with 3 different processing devices (Aegis HM, Trione Z, Motion 2). The marginal gap, absolute marginal discrepancy, internal gap(axial, line angle, occlusal) by a silicone replica technique were measured to compare the fit of the crown. The scanned inner and outer surfaces of the crowns were compared to CAD data using 3D metrology software to evaluate trueness. RESULTS: There were significant differences in the marginal gap, absolute marginal discrepancy, axial and line angle internal gap among the groups (P < .05) in the comparison of fit. There was no statistically significant difference among the groups in terms of occlusal internal gap. The trueness ranged from 36.19 to 43.78 µm but there was no statistically significant difference within the groups (P > .05). CONCLUSION: All 9 groups showed clinically acceptable level of marginal gaps ranging from 74.26 to 112.20 µm in terms of fit comparison. In the comparison of trueness, no significant difference within each group was spotted. Within the limitation of this study, open CAD-CAM systems used in this study can be assembled properly to fabricate zirconia crown. |
format | Online Article Text |
id | pubmed-10333096 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-103330962023-07-12 Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems Bae, Eun-Bin Cho, Won-Tak Park, Do-Hyun Hwang, Su-Hyun Lee, So-Hyoun Yun, Mi-Jung Jeong, Chang-Mo Huh, Jung-Bo J Adv Prosthodont Original Article PURPOSE: This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. MATERIALS AND METHODS: Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was made through the cross-application of 3 different design software (EZIS VR, 3Shape Dental System, Exocad) with 3 different processing devices (Aegis HM, Trione Z, Motion 2). The marginal gap, absolute marginal discrepancy, internal gap(axial, line angle, occlusal) by a silicone replica technique were measured to compare the fit of the crown. The scanned inner and outer surfaces of the crowns were compared to CAD data using 3D metrology software to evaluate trueness. RESULTS: There were significant differences in the marginal gap, absolute marginal discrepancy, axial and line angle internal gap among the groups (P < .05) in the comparison of fit. There was no statistically significant difference among the groups in terms of occlusal internal gap. The trueness ranged from 36.19 to 43.78 µm but there was no statistically significant difference within the groups (P > .05). CONCLUSION: All 9 groups showed clinically acceptable level of marginal gaps ranging from 74.26 to 112.20 µm in terms of fit comparison. In the comparison of trueness, no significant difference within each group was spotted. Within the limitation of this study, open CAD-CAM systems used in this study can be assembled properly to fabricate zirconia crown. The Korean Academy of Prosthodontics 2023-06 2023-06-28 /pmc/articles/PMC10333096/ /pubmed/37441720 http://dx.doi.org/10.4047/jap.2023.15.3.155 Text en © 2023 The Korean Academy of Prosthodontics https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Bae, Eun-Bin Cho, Won-Tak Park, Do-Hyun Hwang, Su-Hyun Lee, So-Hyoun Yun, Mi-Jung Jeong, Chang-Mo Huh, Jung-Bo Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems |
title | Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems |
title_full | Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems |
title_fullStr | Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems |
title_full_unstemmed | Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems |
title_short | Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems |
title_sort | comparison of fit and trueness of zirconia crowns fabricated by different combinations of open cad-cam systems |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10333096/ https://www.ncbi.nlm.nih.gov/pubmed/37441720 http://dx.doi.org/10.4047/jap.2023.15.3.155 |
work_keys_str_mv | AT baeeunbin comparisonoffitandtruenessofzirconiacrownsfabricatedbydifferentcombinationsofopencadcamsystems AT chowontak comparisonoffitandtruenessofzirconiacrownsfabricatedbydifferentcombinationsofopencadcamsystems AT parkdohyun comparisonoffitandtruenessofzirconiacrownsfabricatedbydifferentcombinationsofopencadcamsystems AT hwangsuhyun comparisonoffitandtruenessofzirconiacrownsfabricatedbydifferentcombinationsofopencadcamsystems AT leesohyoun comparisonoffitandtruenessofzirconiacrownsfabricatedbydifferentcombinationsofopencadcamsystems AT yunmijung comparisonoffitandtruenessofzirconiacrownsfabricatedbydifferentcombinationsofopencadcamsystems AT jeongchangmo comparisonoffitandtruenessofzirconiacrownsfabricatedbydifferentcombinationsofopencadcamsystems AT huhjungbo comparisonoffitandtruenessofzirconiacrownsfabricatedbydifferentcombinationsofopencadcamsystems |