Cargando…

Comparison of EEG Source Localization Using Simplified and Anatomically Accurate Head Models in Younger and Older Adults

Accuracy of electroencephalography (EEG) source localization relies on the volume conduction head model. A previous analysis of young adults has shown that simplified head models have larger source localization errors when compared with head models based on magnetic resonance images (MRIs). As obtai...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Chang, Downey, Ryan J., Mu, Yiru, Richer, Natalie, Hwang, Jungyun, Shah, Valay A., Sato, Sumire D., Clark, David J., Hass, Chris J., Manini, Todd M., Seidler, Rachael D., Ferris, Daniel P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10336858/
https://www.ncbi.nlm.nih.gov/pubmed/37252873
http://dx.doi.org/10.1109/TNSRE.2023.3281356
_version_ 1785071291441610752
author Liu, Chang
Downey, Ryan J.
Mu, Yiru
Richer, Natalie
Hwang, Jungyun
Shah, Valay A.
Sato, Sumire D.
Clark, David J.
Hass, Chris J.
Manini, Todd M.
Seidler, Rachael D.
Ferris, Daniel P.
author_facet Liu, Chang
Downey, Ryan J.
Mu, Yiru
Richer, Natalie
Hwang, Jungyun
Shah, Valay A.
Sato, Sumire D.
Clark, David J.
Hass, Chris J.
Manini, Todd M.
Seidler, Rachael D.
Ferris, Daniel P.
author_sort Liu, Chang
collection PubMed
description Accuracy of electroencephalography (EEG) source localization relies on the volume conduction head model. A previous analysis of young adults has shown that simplified head models have larger source localization errors when compared with head models based on magnetic resonance images (MRIs). As obtaining individual MRIs may not always be feasible, researchers often use generic head models based on template MRIs. It is unclear how much error would be introduced using template MRI head models in older adults that likely have differences in brain structure compared to young adults. The primary goal of this study was to determine the error caused by using simplified head models without individual-specific MRIs in both younger and older adults. We collected high-density EEG during uneven terrain walking and motor imagery for 15 younger (22±3 years) and 21 older adults (74±5 years) and obtained T(1)-weighted MRI for each individual. We performed equivalent dipole fitting after independent component analysis to obtain brain source locations using four forward modeling pipelines with increasing complexity. These pipelines included: 1) a generic head model with template electrode positions or 2) digitized electrode positions, 3) individual-specific head models with digitized electrode positions using simplified tissue segmentation, or 4) anatomically accurate segmentation. We found that when compared to the anatomically accurate individual-specific head models, performing dipole fitting with generic head models led to similar source localization discrepancies (up to 2 cm) for younger and older adults. Co-registering digitized electrode locations to the generic head models reduced source localization discrepancies by ~6 mm. Additionally, we found that source depths generally increased with skull conductivity for the representative young adult but not as much for the older adult. Our results can help inform a more accurate interpretation of brain areas in EEG studies when individual MRIs are unavailable.
format Online
Article
Text
id pubmed-10336858
institution National Center for Biotechnology Information
language English
publishDate 2023
record_format MEDLINE/PubMed
spelling pubmed-103368582023-07-12 Comparison of EEG Source Localization Using Simplified and Anatomically Accurate Head Models in Younger and Older Adults Liu, Chang Downey, Ryan J. Mu, Yiru Richer, Natalie Hwang, Jungyun Shah, Valay A. Sato, Sumire D. Clark, David J. Hass, Chris J. Manini, Todd M. Seidler, Rachael D. Ferris, Daniel P. IEEE Trans Neural Syst Rehabil Eng Article Accuracy of electroencephalography (EEG) source localization relies on the volume conduction head model. A previous analysis of young adults has shown that simplified head models have larger source localization errors when compared with head models based on magnetic resonance images (MRIs). As obtaining individual MRIs may not always be feasible, researchers often use generic head models based on template MRIs. It is unclear how much error would be introduced using template MRI head models in older adults that likely have differences in brain structure compared to young adults. The primary goal of this study was to determine the error caused by using simplified head models without individual-specific MRIs in both younger and older adults. We collected high-density EEG during uneven terrain walking and motor imagery for 15 younger (22±3 years) and 21 older adults (74±5 years) and obtained T(1)-weighted MRI for each individual. We performed equivalent dipole fitting after independent component analysis to obtain brain source locations using four forward modeling pipelines with increasing complexity. These pipelines included: 1) a generic head model with template electrode positions or 2) digitized electrode positions, 3) individual-specific head models with digitized electrode positions using simplified tissue segmentation, or 4) anatomically accurate segmentation. We found that when compared to the anatomically accurate individual-specific head models, performing dipole fitting with generic head models led to similar source localization discrepancies (up to 2 cm) for younger and older adults. Co-registering digitized electrode locations to the generic head models reduced source localization discrepancies by ~6 mm. Additionally, we found that source depths generally increased with skull conductivity for the representative young adult but not as much for the older adult. Our results can help inform a more accurate interpretation of brain areas in EEG studies when individual MRIs are unavailable. 2023 2023-06-13 /pmc/articles/PMC10336858/ /pubmed/37252873 http://dx.doi.org/10.1109/TNSRE.2023.3281356 Text en https://creativecommons.org/licenses/by/4.0/This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Liu, Chang
Downey, Ryan J.
Mu, Yiru
Richer, Natalie
Hwang, Jungyun
Shah, Valay A.
Sato, Sumire D.
Clark, David J.
Hass, Chris J.
Manini, Todd M.
Seidler, Rachael D.
Ferris, Daniel P.
Comparison of EEG Source Localization Using Simplified and Anatomically Accurate Head Models in Younger and Older Adults
title Comparison of EEG Source Localization Using Simplified and Anatomically Accurate Head Models in Younger and Older Adults
title_full Comparison of EEG Source Localization Using Simplified and Anatomically Accurate Head Models in Younger and Older Adults
title_fullStr Comparison of EEG Source Localization Using Simplified and Anatomically Accurate Head Models in Younger and Older Adults
title_full_unstemmed Comparison of EEG Source Localization Using Simplified and Anatomically Accurate Head Models in Younger and Older Adults
title_short Comparison of EEG Source Localization Using Simplified and Anatomically Accurate Head Models in Younger and Older Adults
title_sort comparison of eeg source localization using simplified and anatomically accurate head models in younger and older adults
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10336858/
https://www.ncbi.nlm.nih.gov/pubmed/37252873
http://dx.doi.org/10.1109/TNSRE.2023.3281356
work_keys_str_mv AT liuchang comparisonofeegsourcelocalizationusingsimplifiedandanatomicallyaccurateheadmodelsinyoungerandolderadults
AT downeyryanj comparisonofeegsourcelocalizationusingsimplifiedandanatomicallyaccurateheadmodelsinyoungerandolderadults
AT muyiru comparisonofeegsourcelocalizationusingsimplifiedandanatomicallyaccurateheadmodelsinyoungerandolderadults
AT richernatalie comparisonofeegsourcelocalizationusingsimplifiedandanatomicallyaccurateheadmodelsinyoungerandolderadults
AT hwangjungyun comparisonofeegsourcelocalizationusingsimplifiedandanatomicallyaccurateheadmodelsinyoungerandolderadults
AT shahvalaya comparisonofeegsourcelocalizationusingsimplifiedandanatomicallyaccurateheadmodelsinyoungerandolderadults
AT satosumired comparisonofeegsourcelocalizationusingsimplifiedandanatomicallyaccurateheadmodelsinyoungerandolderadults
AT clarkdavidj comparisonofeegsourcelocalizationusingsimplifiedandanatomicallyaccurateheadmodelsinyoungerandolderadults
AT hasschrisj comparisonofeegsourcelocalizationusingsimplifiedandanatomicallyaccurateheadmodelsinyoungerandolderadults
AT maninitoddm comparisonofeegsourcelocalizationusingsimplifiedandanatomicallyaccurateheadmodelsinyoungerandolderadults
AT seidlerrachaeld comparisonofeegsourcelocalizationusingsimplifiedandanatomicallyaccurateheadmodelsinyoungerandolderadults
AT ferrisdanielp comparisonofeegsourcelocalizationusingsimplifiedandanatomicallyaccurateheadmodelsinyoungerandolderadults