Cargando…
Automated Camera Lucida Method with Colored Images through Integration of Hardware and Software in Microscopic Zooming
Automating the camera Lucida method which is a standard way for focusing microscopic images is a very challenging study for many scientists. Hence, actually combining hardware and software to automate microscopic imaging systems is one of the most important issues in the field of medicine as well. T...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10336917/ https://www.ncbi.nlm.nih.gov/pubmed/37448549 http://dx.doi.org/10.4103/jmss.jmss_125_21 |
_version_ | 1785071304936783872 |
---|---|
author | Vahabi, Fateme Kermani, Saeed Vahabi, Zahra Pestechian, Nader |
author_facet | Vahabi, Fateme Kermani, Saeed Vahabi, Zahra Pestechian, Nader |
author_sort | Vahabi, Fateme |
collection | PubMed |
description | Automating the camera Lucida method which is a standard way for focusing microscopic images is a very challenging study for many scientists. Hence, actually combining hardware and software to automate microscopic imaging systems is one of the most important issues in the field of medicine as well. This idea reduces scanning time and increases the accuracy of user's results in this field. Closed-loop control system has been designed and implemented in the hardware part to move the stage in predefined limits of 15°. This system produces 50 consecutive images from parasites at the mentioned spatial distances in two directions of the z-axis. Then, by introducing our proposed relational software with combining images, a high-contrast image can be presented. This colored image is focused on many subparts of the sample even with different ruggedness. After implementing the closed-loop controller, stages movement was repeated eight times with an average step displacement of 20 μm which were measured in two directions of the z-axis by a digital micrometer. On average, the movement's error was 1 μm. In software, the edge intensity energy index has been calculated for image quality evaluation. The standard camera Lucida method has been simulated with acceptable results based on experts' opinions and also mean squared error parameters. Mechanical movement in stage has an accuracy of about 95% which will meet the expectations of laboratory user. Although output-focused colored images from our combining software can be replaced by the traditional fully accepted Camera Lucida method. |
format | Online Article Text |
id | pubmed-10336917 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-103369172023-07-13 Automated Camera Lucida Method with Colored Images through Integration of Hardware and Software in Microscopic Zooming Vahabi, Fateme Kermani, Saeed Vahabi, Zahra Pestechian, Nader J Med Signals Sens Short Communication Automating the camera Lucida method which is a standard way for focusing microscopic images is a very challenging study for many scientists. Hence, actually combining hardware and software to automate microscopic imaging systems is one of the most important issues in the field of medicine as well. This idea reduces scanning time and increases the accuracy of user's results in this field. Closed-loop control system has been designed and implemented in the hardware part to move the stage in predefined limits of 15°. This system produces 50 consecutive images from parasites at the mentioned spatial distances in two directions of the z-axis. Then, by introducing our proposed relational software with combining images, a high-contrast image can be presented. This colored image is focused on many subparts of the sample even with different ruggedness. After implementing the closed-loop controller, stages movement was repeated eight times with an average step displacement of 20 μm which were measured in two directions of the z-axis by a digital micrometer. On average, the movement's error was 1 μm. In software, the edge intensity energy index has been calculated for image quality evaluation. The standard camera Lucida method has been simulated with acceptable results based on experts' opinions and also mean squared error parameters. Mechanical movement in stage has an accuracy of about 95% which will meet the expectations of laboratory user. Although output-focused colored images from our combining software can be replaced by the traditional fully accepted Camera Lucida method. Wolters Kluwer - Medknow 2023-05-29 /pmc/articles/PMC10336917/ /pubmed/37448549 http://dx.doi.org/10.4103/jmss.jmss_125_21 Text en Copyright: © 2023 Journal of Medical Signals & Sensors https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Short Communication Vahabi, Fateme Kermani, Saeed Vahabi, Zahra Pestechian, Nader Automated Camera Lucida Method with Colored Images through Integration of Hardware and Software in Microscopic Zooming |
title | Automated Camera Lucida Method with Colored Images through Integration of Hardware and Software in Microscopic Zooming |
title_full | Automated Camera Lucida Method with Colored Images through Integration of Hardware and Software in Microscopic Zooming |
title_fullStr | Automated Camera Lucida Method with Colored Images through Integration of Hardware and Software in Microscopic Zooming |
title_full_unstemmed | Automated Camera Lucida Method with Colored Images through Integration of Hardware and Software in Microscopic Zooming |
title_short | Automated Camera Lucida Method with Colored Images through Integration of Hardware and Software in Microscopic Zooming |
title_sort | automated camera lucida method with colored images through integration of hardware and software in microscopic zooming |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10336917/ https://www.ncbi.nlm.nih.gov/pubmed/37448549 http://dx.doi.org/10.4103/jmss.jmss_125_21 |
work_keys_str_mv | AT vahabifateme automatedcameralucidamethodwithcoloredimagesthroughintegrationofhardwareandsoftwareinmicroscopiczooming AT kermanisaeed automatedcameralucidamethodwithcoloredimagesthroughintegrationofhardwareandsoftwareinmicroscopiczooming AT vahabizahra automatedcameralucidamethodwithcoloredimagesthroughintegrationofhardwareandsoftwareinmicroscopiczooming AT pestechiannader automatedcameralucidamethodwithcoloredimagesthroughintegrationofhardwareandsoftwareinmicroscopiczooming |