Cargando…

A retrospective multi‐center feasibility study of a new PTV margin estimation approach for moving targets using CyberKnife log files

PURPOSE: This study investigates a new approach for estimating the planning target volume (PTV) margin for moving tumors treated with robotic stereotactic body radiotherapy (SBRT). METHODS: In this new approach, the covariance of modeling and prediction errors was estimated using error propagation a...

Descripción completa

Detalles Bibliográficos
Autores principales: Samadi Miandoab, Payam, Saramad, Shahyar, Setayeshi, Saeed, Blanck, Oliver
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10338771/
https://www.ncbi.nlm.nih.gov/pubmed/37004149
http://dx.doi.org/10.1002/acm2.13975
_version_ 1785071698211504128
author Samadi Miandoab, Payam
Saramad, Shahyar
Setayeshi, Saeed
Blanck, Oliver
author_facet Samadi Miandoab, Payam
Saramad, Shahyar
Setayeshi, Saeed
Blanck, Oliver
author_sort Samadi Miandoab, Payam
collection PubMed
description PURPOSE: This study investigates a new approach for estimating the planning target volume (PTV) margin for moving tumors treated with robotic stereotactic body radiotherapy (SBRT). METHODS: In this new approach, the covariance of modeling and prediction errors was estimated using error propagation and implemented in the Van Herk formula to form a Modified Van Herk formula (MVHF). To perform a retrospective multi‐center analysis, the MVHF was studied using 163 patients treated with different system versions of robotic SBRT (G3 version 6.2.3, VSI version 8.5, and VSI version 9.5) and compared with two established PTV margins estimation methods: The original Van Herk Formula (VHF) and the Uncertainty Estimation Method (UEM). RESULTS: Overall, the PTV margins provided by the three formalisms are similar with 4–5 mm in the lung region and 4 mm in abdomen region to the PTV margins used in clinical. Furthermore, when analyzing individual patients, a difference of up to 1 mm was found between the PTV margin estimations using MVHF and VHF. The corresponding average discrepancies for the superior‐inferior (SI) direction ranged between −0.19 mm to 0.38 mm in CK G3 version 6.2.3, −0.36 mm to 0.33 mm in CK VSI version 8.5, and −0.34 mm to 0.40 mm in CK VSI version 9.5. CONCLUSIONS: It was found that for the lower left lung, upper left lung, lower right lung, upper right lung, central liver, and upper liver, the effect of covariance between model and prediction errors in SI direction was around 20%, 30%, 25%, 25%, 25%, and 30%, respectively. Notable covariance effects between model and prediction errors can be considered in PTV margin estimation using a modified VHF, which allowed for more precise target localization in robotic SBRT for moving tumors. Overall, in each of the three directions, the difference between MVHF and utilized clinical margins is 0.65 mm in the lung and abdominal region. Therefore, to improve the clinical PTV margins with the new approach, it is suggested to use the adaptive PTV margins in the next fractions.
format Online
Article
Text
id pubmed-10338771
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-103387712023-07-14 A retrospective multi‐center feasibility study of a new PTV margin estimation approach for moving targets using CyberKnife log files Samadi Miandoab, Payam Saramad, Shahyar Setayeshi, Saeed Blanck, Oliver J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: This study investigates a new approach for estimating the planning target volume (PTV) margin for moving tumors treated with robotic stereotactic body radiotherapy (SBRT). METHODS: In this new approach, the covariance of modeling and prediction errors was estimated using error propagation and implemented in the Van Herk formula to form a Modified Van Herk formula (MVHF). To perform a retrospective multi‐center analysis, the MVHF was studied using 163 patients treated with different system versions of robotic SBRT (G3 version 6.2.3, VSI version 8.5, and VSI version 9.5) and compared with two established PTV margins estimation methods: The original Van Herk Formula (VHF) and the Uncertainty Estimation Method (UEM). RESULTS: Overall, the PTV margins provided by the three formalisms are similar with 4–5 mm in the lung region and 4 mm in abdomen region to the PTV margins used in clinical. Furthermore, when analyzing individual patients, a difference of up to 1 mm was found between the PTV margin estimations using MVHF and VHF. The corresponding average discrepancies for the superior‐inferior (SI) direction ranged between −0.19 mm to 0.38 mm in CK G3 version 6.2.3, −0.36 mm to 0.33 mm in CK VSI version 8.5, and −0.34 mm to 0.40 mm in CK VSI version 9.5. CONCLUSIONS: It was found that for the lower left lung, upper left lung, lower right lung, upper right lung, central liver, and upper liver, the effect of covariance between model and prediction errors in SI direction was around 20%, 30%, 25%, 25%, 25%, and 30%, respectively. Notable covariance effects between model and prediction errors can be considered in PTV margin estimation using a modified VHF, which allowed for more precise target localization in robotic SBRT for moving tumors. Overall, in each of the three directions, the difference between MVHF and utilized clinical margins is 0.65 mm in the lung and abdominal region. Therefore, to improve the clinical PTV margins with the new approach, it is suggested to use the adaptive PTV margins in the next fractions. John Wiley and Sons Inc. 2023-04-01 /pmc/articles/PMC10338771/ /pubmed/37004149 http://dx.doi.org/10.1002/acm2.13975 Text en © 2023 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Samadi Miandoab, Payam
Saramad, Shahyar
Setayeshi, Saeed
Blanck, Oliver
A retrospective multi‐center feasibility study of a new PTV margin estimation approach for moving targets using CyberKnife log files
title A retrospective multi‐center feasibility study of a new PTV margin estimation approach for moving targets using CyberKnife log files
title_full A retrospective multi‐center feasibility study of a new PTV margin estimation approach for moving targets using CyberKnife log files
title_fullStr A retrospective multi‐center feasibility study of a new PTV margin estimation approach for moving targets using CyberKnife log files
title_full_unstemmed A retrospective multi‐center feasibility study of a new PTV margin estimation approach for moving targets using CyberKnife log files
title_short A retrospective multi‐center feasibility study of a new PTV margin estimation approach for moving targets using CyberKnife log files
title_sort retrospective multi‐center feasibility study of a new ptv margin estimation approach for moving targets using cyberknife log files
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10338771/
https://www.ncbi.nlm.nih.gov/pubmed/37004149
http://dx.doi.org/10.1002/acm2.13975
work_keys_str_mv AT samadimiandoabpayam aretrospectivemulticenterfeasibilitystudyofanewptvmarginestimationapproachformovingtargetsusingcyberknifelogfiles
AT saramadshahyar aretrospectivemulticenterfeasibilitystudyofanewptvmarginestimationapproachformovingtargetsusingcyberknifelogfiles
AT setayeshisaeed aretrospectivemulticenterfeasibilitystudyofanewptvmarginestimationapproachformovingtargetsusingcyberknifelogfiles
AT blanckoliver aretrospectivemulticenterfeasibilitystudyofanewptvmarginestimationapproachformovingtargetsusingcyberknifelogfiles
AT samadimiandoabpayam retrospectivemulticenterfeasibilitystudyofanewptvmarginestimationapproachformovingtargetsusingcyberknifelogfiles
AT saramadshahyar retrospectivemulticenterfeasibilitystudyofanewptvmarginestimationapproachformovingtargetsusingcyberknifelogfiles
AT setayeshisaeed retrospectivemulticenterfeasibilitystudyofanewptvmarginestimationapproachformovingtargetsusingcyberknifelogfiles
AT blanckoliver retrospectivemulticenterfeasibilitystudyofanewptvmarginestimationapproachformovingtargetsusingcyberknifelogfiles