Cargando…

Tensile Bond Strength and Marginal Integrity of a Self-adhering and a Self-etch Adhesive Flowable Composite after Artificial Thermomechanical Aging

AIM: This study aims to compare the self-etch adhesive (SEA) and self-adhesive flowable composite (SAF) concerning tensile bond strength (TBS) and marginal integrity by microleakage (µ LK) test in deciduous molars after artificial thermomechanical aging. MATERIALS AND METHODS: 120 extracted primary...

Descripción completa

Detalles Bibliográficos
Autores principales: Kamatchi, Mohanraj, Ajay, Ranganathan, Gawthaman, Murugesan, Maheshmathian, Veerabadhran, Preethi, Kumaragurubaran, Gayatrikumary, Thiyagarajan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Jaypee Brothers Medical Publishers 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10338951/
https://www.ncbi.nlm.nih.gov/pubmed/37457209
http://dx.doi.org/10.5005/jp-journals-10005-2370
_version_ 1785071742454071296
author Kamatchi, Mohanraj
Ajay, Ranganathan
Gawthaman, Murugesan
Maheshmathian, Veerabadhran
Preethi, Kumaragurubaran
Gayatrikumary, Thiyagarajan
author_facet Kamatchi, Mohanraj
Ajay, Ranganathan
Gawthaman, Murugesan
Maheshmathian, Veerabadhran
Preethi, Kumaragurubaran
Gayatrikumary, Thiyagarajan
author_sort Kamatchi, Mohanraj
collection PubMed
description AIM: This study aims to compare the self-etch adhesive (SEA) and self-adhesive flowable composite (SAF) concerning tensile bond strength (TBS) and marginal integrity by microleakage (µ LK) test in deciduous molars after artificial thermomechanical aging. MATERIALS AND METHODS: 120 extracted primary molars were collected. Sixty teeth were mounted for testing TBS. Teeth were restored using SAF (n = 30) and SEA-conventional flowable (CF) composite (n = 30) and subjected to artificial thermal aging. Half the teeth (n = 15) from each material were subjected to mechanical loading (SEA-TBS-L and SAF-TBS-L). The specimens with no-load (NL) served as control (SEA-TBS-NL and SAF-TBS-NL). Class V cavity prepared and restored with SAF (n = 30) and SEA-CF (n = 30) to test µ LK after thermal aging. The subgroups were as same as the TBS based on with or without mechanical loading (SEA-µ LK-L, SEA-µ LK-NL, SAF-µ LK-L, SAF-µ LK-L; n = 15 each). µ LK was determined by employing the dye immersion technique. RESULTS: Concerning TBS, there is a significant difference between SEA and SAF with load or no load. Concerning µ LK, there is a significant difference between the materials under loading and no difference was found when not mechanically loaded. Also, concerning both TBS and µ LK, a significant difference was observed between the load and no-load subgroups within each material. CONCLUSION: SAF exhibited higher TBS than the SEA. Mechanical loading not only adversely affected the TBS but also increased the µLK of the compared materials. CLINICAL SIGNIFICANCE: Restoring the primary teeth with SAF not only shortens the laborious operatory time but also yields good clinical serviceability with the good bond strength and minimal µ LK, thus preventing premature loss of teeth and consequential malocclusion. HOW TO CITE THIS ARTICLE: Kamatchi M, Ajay R, Gawthaman M, et al. Tensile Bond Strength and Marginal Integrity of a Self-adhering and a Self-etch Adhesive Flowable Composite after Artificial Thermomechanical Aging. Int J Clin Pediatr Dent 2022;15(2):204-209.
format Online
Article
Text
id pubmed-10338951
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Jaypee Brothers Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-103389512023-07-14 Tensile Bond Strength and Marginal Integrity of a Self-adhering and a Self-etch Adhesive Flowable Composite after Artificial Thermomechanical Aging Kamatchi, Mohanraj Ajay, Ranganathan Gawthaman, Murugesan Maheshmathian, Veerabadhran Preethi, Kumaragurubaran Gayatrikumary, Thiyagarajan Int J Clin Pediatr Dent Research Article AIM: This study aims to compare the self-etch adhesive (SEA) and self-adhesive flowable composite (SAF) concerning tensile bond strength (TBS) and marginal integrity by microleakage (µ LK) test in deciduous molars after artificial thermomechanical aging. MATERIALS AND METHODS: 120 extracted primary molars were collected. Sixty teeth were mounted for testing TBS. Teeth were restored using SAF (n = 30) and SEA-conventional flowable (CF) composite (n = 30) and subjected to artificial thermal aging. Half the teeth (n = 15) from each material were subjected to mechanical loading (SEA-TBS-L and SAF-TBS-L). The specimens with no-load (NL) served as control (SEA-TBS-NL and SAF-TBS-NL). Class V cavity prepared and restored with SAF (n = 30) and SEA-CF (n = 30) to test µ LK after thermal aging. The subgroups were as same as the TBS based on with or without mechanical loading (SEA-µ LK-L, SEA-µ LK-NL, SAF-µ LK-L, SAF-µ LK-L; n = 15 each). µ LK was determined by employing the dye immersion technique. RESULTS: Concerning TBS, there is a significant difference between SEA and SAF with load or no load. Concerning µ LK, there is a significant difference between the materials under loading and no difference was found when not mechanically loaded. Also, concerning both TBS and µ LK, a significant difference was observed between the load and no-load subgroups within each material. CONCLUSION: SAF exhibited higher TBS than the SEA. Mechanical loading not only adversely affected the TBS but also increased the µLK of the compared materials. CLINICAL SIGNIFICANCE: Restoring the primary teeth with SAF not only shortens the laborious operatory time but also yields good clinical serviceability with the good bond strength and minimal µ LK, thus preventing premature loss of teeth and consequential malocclusion. HOW TO CITE THIS ARTICLE: Kamatchi M, Ajay R, Gawthaman M, et al. Tensile Bond Strength and Marginal Integrity of a Self-adhering and a Self-etch Adhesive Flowable Composite after Artificial Thermomechanical Aging. Int J Clin Pediatr Dent 2022;15(2):204-209. Jaypee Brothers Medical Publishers 2022 /pmc/articles/PMC10338951/ /pubmed/37457209 http://dx.doi.org/10.5005/jp-journals-10005-2370 Text en Copyright © 2022; The Author(s). https://creativecommons.org/licenses/by-nc/4.0/© The Author(s). 2022 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Kamatchi, Mohanraj
Ajay, Ranganathan
Gawthaman, Murugesan
Maheshmathian, Veerabadhran
Preethi, Kumaragurubaran
Gayatrikumary, Thiyagarajan
Tensile Bond Strength and Marginal Integrity of a Self-adhering and a Self-etch Adhesive Flowable Composite after Artificial Thermomechanical Aging
title Tensile Bond Strength and Marginal Integrity of a Self-adhering and a Self-etch Adhesive Flowable Composite after Artificial Thermomechanical Aging
title_full Tensile Bond Strength and Marginal Integrity of a Self-adhering and a Self-etch Adhesive Flowable Composite after Artificial Thermomechanical Aging
title_fullStr Tensile Bond Strength and Marginal Integrity of a Self-adhering and a Self-etch Adhesive Flowable Composite after Artificial Thermomechanical Aging
title_full_unstemmed Tensile Bond Strength and Marginal Integrity of a Self-adhering and a Self-etch Adhesive Flowable Composite after Artificial Thermomechanical Aging
title_short Tensile Bond Strength and Marginal Integrity of a Self-adhering and a Self-etch Adhesive Flowable Composite after Artificial Thermomechanical Aging
title_sort tensile bond strength and marginal integrity of a self-adhering and a self-etch adhesive flowable composite after artificial thermomechanical aging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10338951/
https://www.ncbi.nlm.nih.gov/pubmed/37457209
http://dx.doi.org/10.5005/jp-journals-10005-2370
work_keys_str_mv AT kamatchimohanraj tensilebondstrengthandmarginalintegrityofaselfadheringandaselfetchadhesiveflowablecompositeafterartificialthermomechanicalaging
AT ajayranganathan tensilebondstrengthandmarginalintegrityofaselfadheringandaselfetchadhesiveflowablecompositeafterartificialthermomechanicalaging
AT gawthamanmurugesan tensilebondstrengthandmarginalintegrityofaselfadheringandaselfetchadhesiveflowablecompositeafterartificialthermomechanicalaging
AT maheshmathianveerabadhran tensilebondstrengthandmarginalintegrityofaselfadheringandaselfetchadhesiveflowablecompositeafterartificialthermomechanicalaging
AT preethikumaragurubaran tensilebondstrengthandmarginalintegrityofaselfadheringandaselfetchadhesiveflowablecompositeafterartificialthermomechanicalaging
AT gayatrikumarythiyagarajan tensilebondstrengthandmarginalintegrityofaselfadheringandaselfetchadhesiveflowablecompositeafterartificialthermomechanicalaging