Cargando…
Novel use and utilization of robotic Hoyer–Hook system for suspension of panniculus morbidus
Panniculus morbidus is a complication of morbid obesity characterized by massive abdominal folds that hang below the beltline. Ulceration, dermatitis, and sinus tract formation of the pannus can cause significant morbidity to the patient and impair activities of daily living. If patients fail medica...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10339113/ https://www.ncbi.nlm.nih.gov/pubmed/37457989 http://dx.doi.org/10.1016/j.jpra.2023.06.011 |
_version_ | 1785071780457611264 |
---|---|
author | Malkoc, Aldin Landau, Mark J. Shoemaker, Hailey Leong, Darren Sze Mynn Chang, Walter T. |
author_facet | Malkoc, Aldin Landau, Mark J. Shoemaker, Hailey Leong, Darren Sze Mynn Chang, Walter T. |
author_sort | Malkoc, Aldin |
collection | PubMed |
description | Panniculus morbidus is a complication of morbid obesity characterized by massive abdominal folds that hang below the beltline. Ulceration, dermatitis, and sinus tract formation of the pannus can cause significant morbidity to the patient and impair activities of daily living. If patients fail medical management, the next step is surgical excision. Challenging aspects of the procedure include adequate suspension of the pannus, cost, and prevention of intra-abdominal injuries. We present a case of a 70-year-old female with panniculus morbidus with endometrial carcinoma. We successfully performed a panniculectomy using a novel combination of towel hooks and the Hoyer lift to suspend the abdomen. In the same anesthesia event, she underwent robotic-assisted hysterectomy. No intra-operative or post-operative complications were encountered, and the patient was satisfied with her results. In this case, we demonstrated an effective and cost-efficient approach to panniculectomy in the severely obese patient. |
format | Online Article Text |
id | pubmed-10339113 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-103391132023-07-14 Novel use and utilization of robotic Hoyer–Hook system for suspension of panniculus morbidus Malkoc, Aldin Landau, Mark J. Shoemaker, Hailey Leong, Darren Sze Mynn Chang, Walter T. JPRAS Open Short Communication Panniculus morbidus is a complication of morbid obesity characterized by massive abdominal folds that hang below the beltline. Ulceration, dermatitis, and sinus tract formation of the pannus can cause significant morbidity to the patient and impair activities of daily living. If patients fail medical management, the next step is surgical excision. Challenging aspects of the procedure include adequate suspension of the pannus, cost, and prevention of intra-abdominal injuries. We present a case of a 70-year-old female with panniculus morbidus with endometrial carcinoma. We successfully performed a panniculectomy using a novel combination of towel hooks and the Hoyer lift to suspend the abdomen. In the same anesthesia event, she underwent robotic-assisted hysterectomy. No intra-operative or post-operative complications were encountered, and the patient was satisfied with her results. In this case, we demonstrated an effective and cost-efficient approach to panniculectomy in the severely obese patient. Elsevier 2023-06-26 /pmc/articles/PMC10339113/ /pubmed/37457989 http://dx.doi.org/10.1016/j.jpra.2023.06.011 Text en © 2023 The Authors. Published by Elsevier Ltd on behalf of British Association of Plastic, Reconstructive and Aesthetic Surgeons. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Short Communication Malkoc, Aldin Landau, Mark J. Shoemaker, Hailey Leong, Darren Sze Mynn Chang, Walter T. Novel use and utilization of robotic Hoyer–Hook system for suspension of panniculus morbidus |
title | Novel use and utilization of robotic Hoyer–Hook system for suspension of panniculus morbidus |
title_full | Novel use and utilization of robotic Hoyer–Hook system for suspension of panniculus morbidus |
title_fullStr | Novel use and utilization of robotic Hoyer–Hook system for suspension of panniculus morbidus |
title_full_unstemmed | Novel use and utilization of robotic Hoyer–Hook system for suspension of panniculus morbidus |
title_short | Novel use and utilization of robotic Hoyer–Hook system for suspension of panniculus morbidus |
title_sort | novel use and utilization of robotic hoyer–hook system for suspension of panniculus morbidus |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10339113/ https://www.ncbi.nlm.nih.gov/pubmed/37457989 http://dx.doi.org/10.1016/j.jpra.2023.06.011 |
work_keys_str_mv | AT malkocaldin noveluseandutilizationofrobotichoyerhooksystemforsuspensionofpanniculusmorbidus AT landaumarkj noveluseandutilizationofrobotichoyerhooksystemforsuspensionofpanniculusmorbidus AT shoemakerhailey noveluseandutilizationofrobotichoyerhooksystemforsuspensionofpanniculusmorbidus AT leongdarrenszemynn noveluseandutilizationofrobotichoyerhooksystemforsuspensionofpanniculusmorbidus AT changwaltert noveluseandutilizationofrobotichoyerhooksystemforsuspensionofpanniculusmorbidus |