Cargando…

Novel use and utilization of robotic Hoyer–Hook system for suspension of panniculus morbidus

Panniculus morbidus is a complication of morbid obesity characterized by massive abdominal folds that hang below the beltline. Ulceration, dermatitis, and sinus tract formation of the pannus can cause significant morbidity to the patient and impair activities of daily living. If patients fail medica...

Descripción completa

Detalles Bibliográficos
Autores principales: Malkoc, Aldin, Landau, Mark J., Shoemaker, Hailey, Leong, Darren Sze Mynn, Chang, Walter T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10339113/
https://www.ncbi.nlm.nih.gov/pubmed/37457989
http://dx.doi.org/10.1016/j.jpra.2023.06.011
_version_ 1785071780457611264
author Malkoc, Aldin
Landau, Mark J.
Shoemaker, Hailey
Leong, Darren Sze Mynn
Chang, Walter T.
author_facet Malkoc, Aldin
Landau, Mark J.
Shoemaker, Hailey
Leong, Darren Sze Mynn
Chang, Walter T.
author_sort Malkoc, Aldin
collection PubMed
description Panniculus morbidus is a complication of morbid obesity characterized by massive abdominal folds that hang below the beltline. Ulceration, dermatitis, and sinus tract formation of the pannus can cause significant morbidity to the patient and impair activities of daily living. If patients fail medical management, the next step is surgical excision. Challenging aspects of the procedure include adequate suspension of the pannus, cost, and prevention of intra-abdominal injuries. We present a case of a 70-year-old female with panniculus morbidus with endometrial carcinoma. We successfully performed a panniculectomy using a novel combination of towel hooks and the Hoyer lift to suspend the abdomen. In the same anesthesia event, she underwent robotic-assisted hysterectomy. No intra-operative or post-operative complications were encountered, and the patient was satisfied with her results. In this case, we demonstrated an effective and cost-efficient approach to panniculectomy in the severely obese patient.
format Online
Article
Text
id pubmed-10339113
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-103391132023-07-14 Novel use and utilization of robotic Hoyer–Hook system for suspension of panniculus morbidus Malkoc, Aldin Landau, Mark J. Shoemaker, Hailey Leong, Darren Sze Mynn Chang, Walter T. JPRAS Open Short Communication Panniculus morbidus is a complication of morbid obesity characterized by massive abdominal folds that hang below the beltline. Ulceration, dermatitis, and sinus tract formation of the pannus can cause significant morbidity to the patient and impair activities of daily living. If patients fail medical management, the next step is surgical excision. Challenging aspects of the procedure include adequate suspension of the pannus, cost, and prevention of intra-abdominal injuries. We present a case of a 70-year-old female with panniculus morbidus with endometrial carcinoma. We successfully performed a panniculectomy using a novel combination of towel hooks and the Hoyer lift to suspend the abdomen. In the same anesthesia event, she underwent robotic-assisted hysterectomy. No intra-operative or post-operative complications were encountered, and the patient was satisfied with her results. In this case, we demonstrated an effective and cost-efficient approach to panniculectomy in the severely obese patient. Elsevier 2023-06-26 /pmc/articles/PMC10339113/ /pubmed/37457989 http://dx.doi.org/10.1016/j.jpra.2023.06.011 Text en © 2023 The Authors. Published by Elsevier Ltd on behalf of British Association of Plastic, Reconstructive and Aesthetic Surgeons. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Short Communication
Malkoc, Aldin
Landau, Mark J.
Shoemaker, Hailey
Leong, Darren Sze Mynn
Chang, Walter T.
Novel use and utilization of robotic Hoyer–Hook system for suspension of panniculus morbidus
title Novel use and utilization of robotic Hoyer–Hook system for suspension of panniculus morbidus
title_full Novel use and utilization of robotic Hoyer–Hook system for suspension of panniculus morbidus
title_fullStr Novel use and utilization of robotic Hoyer–Hook system for suspension of panniculus morbidus
title_full_unstemmed Novel use and utilization of robotic Hoyer–Hook system for suspension of panniculus morbidus
title_short Novel use and utilization of robotic Hoyer–Hook system for suspension of panniculus morbidus
title_sort novel use and utilization of robotic hoyer–hook system for suspension of panniculus morbidus
topic Short Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10339113/
https://www.ncbi.nlm.nih.gov/pubmed/37457989
http://dx.doi.org/10.1016/j.jpra.2023.06.011
work_keys_str_mv AT malkocaldin noveluseandutilizationofrobotichoyerhooksystemforsuspensionofpanniculusmorbidus
AT landaumarkj noveluseandutilizationofrobotichoyerhooksystemforsuspensionofpanniculusmorbidus
AT shoemakerhailey noveluseandutilizationofrobotichoyerhooksystemforsuspensionofpanniculusmorbidus
AT leongdarrenszemynn noveluseandutilizationofrobotichoyerhooksystemforsuspensionofpanniculusmorbidus
AT changwaltert noveluseandutilizationofrobotichoyerhooksystemforsuspensionofpanniculusmorbidus