Cargando…
Relative and Transport Efficiency-Independent Approach for the Determination of Nanoparticle Size Using Single-Particle ICP-MS
[Image: see text] Herein, we introduce the first relative single-particle inductively coupled plasma mass spectrometry (spICP-MS) approach where size calibration is carried out using the target NP itself measured under different instrumental conditions without external dependence on the complex and...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2023
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10339277/ https://www.ncbi.nlm.nih.gov/pubmed/37367956 http://dx.doi.org/10.1021/acs.analchem.3c01823 |
_version_ | 1785071815011336192 |
---|---|
author | Moreira-Álvarez, Borja Cid-Barrio, Laura Calderón-Celis, Francisco Costa-Fernández, José M. Encinar, Jorge Ruiz |
author_facet | Moreira-Álvarez, Borja Cid-Barrio, Laura Calderón-Celis, Francisco Costa-Fernández, José M. Encinar, Jorge Ruiz |
author_sort | Moreira-Álvarez, Borja |
collection | PubMed |
description | [Image: see text] Herein, we introduce the first relative single-particle inductively coupled plasma mass spectrometry (spICP-MS) approach where size calibration is carried out using the target NP itself measured under different instrumental conditions without external dependence on the complex and prone-to-error determination of transport efficiency or mass flux calibrations, in contrast to most spICP-MS approaches. The simple approach proposed allows determining gold nanoparticle (AuNP) sizes, with errors ranging from 0.3 to 3.1% (corroborated by HR-TEM). It has been demonstrated that the changes observed in the single-particle histograms obtained for a suspension of AuNPs under different sensitivity conditions (n = 5) are directly and exclusively related to the mass (size) of the target AuNP itself. Interestingly, the relative nature of the approach shows that once the ICP-MS system has been calibrated with a generic NP standard, it is no longer necessary to repeat the calibration for the size determination of different unimetallic NPs carried out along time (at least 8 months), independently of their size (16–73 nm) and even nature (AuNP or AgNP). Additionally, neither the NP surface functionalization with biomolecules nor protein corona formation led to significant changes (relative errors slightly increased 1.3- to 1.5-fold, up to 7%) in the NP size determination, in contrast to conventional spICP-MS approaches where relative errors increased 2- to 8-fold, up to 32%. This feature could be especially valuable for the analysis of NPs in real samples without the need of matrix-matched calibration. |
format | Online Article Text |
id | pubmed-10339277 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-103392772023-07-14 Relative and Transport Efficiency-Independent Approach for the Determination of Nanoparticle Size Using Single-Particle ICP-MS Moreira-Álvarez, Borja Cid-Barrio, Laura Calderón-Celis, Francisco Costa-Fernández, José M. Encinar, Jorge Ruiz Anal Chem [Image: see text] Herein, we introduce the first relative single-particle inductively coupled plasma mass spectrometry (spICP-MS) approach where size calibration is carried out using the target NP itself measured under different instrumental conditions without external dependence on the complex and prone-to-error determination of transport efficiency or mass flux calibrations, in contrast to most spICP-MS approaches. The simple approach proposed allows determining gold nanoparticle (AuNP) sizes, with errors ranging from 0.3 to 3.1% (corroborated by HR-TEM). It has been demonstrated that the changes observed in the single-particle histograms obtained for a suspension of AuNPs under different sensitivity conditions (n = 5) are directly and exclusively related to the mass (size) of the target AuNP itself. Interestingly, the relative nature of the approach shows that once the ICP-MS system has been calibrated with a generic NP standard, it is no longer necessary to repeat the calibration for the size determination of different unimetallic NPs carried out along time (at least 8 months), independently of their size (16–73 nm) and even nature (AuNP or AgNP). Additionally, neither the NP surface functionalization with biomolecules nor protein corona formation led to significant changes (relative errors slightly increased 1.3- to 1.5-fold, up to 7%) in the NP size determination, in contrast to conventional spICP-MS approaches where relative errors increased 2- to 8-fold, up to 32%. This feature could be especially valuable for the analysis of NPs in real samples without the need of matrix-matched calibration. American Chemical Society 2023-06-27 /pmc/articles/PMC10339277/ /pubmed/37367956 http://dx.doi.org/10.1021/acs.analchem.3c01823 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Moreira-Álvarez, Borja Cid-Barrio, Laura Calderón-Celis, Francisco Costa-Fernández, José M. Encinar, Jorge Ruiz Relative and Transport Efficiency-Independent Approach for the Determination of Nanoparticle Size Using Single-Particle ICP-MS |
title | Relative and
Transport Efficiency-Independent Approach
for the Determination of Nanoparticle Size Using Single-Particle ICP-MS |
title_full | Relative and
Transport Efficiency-Independent Approach
for the Determination of Nanoparticle Size Using Single-Particle ICP-MS |
title_fullStr | Relative and
Transport Efficiency-Independent Approach
for the Determination of Nanoparticle Size Using Single-Particle ICP-MS |
title_full_unstemmed | Relative and
Transport Efficiency-Independent Approach
for the Determination of Nanoparticle Size Using Single-Particle ICP-MS |
title_short | Relative and
Transport Efficiency-Independent Approach
for the Determination of Nanoparticle Size Using Single-Particle ICP-MS |
title_sort | relative and
transport efficiency-independent approach
for the determination of nanoparticle size using single-particle icp-ms |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10339277/ https://www.ncbi.nlm.nih.gov/pubmed/37367956 http://dx.doi.org/10.1021/acs.analchem.3c01823 |
work_keys_str_mv | AT moreiraalvarezborja relativeandtransportefficiencyindependentapproachforthedeterminationofnanoparticlesizeusingsingleparticleicpms AT cidbarriolaura relativeandtransportefficiencyindependentapproachforthedeterminationofnanoparticlesizeusingsingleparticleicpms AT calderoncelisfrancisco relativeandtransportefficiencyindependentapproachforthedeterminationofnanoparticlesizeusingsingleparticleicpms AT costafernandezjosem relativeandtransportefficiencyindependentapproachforthedeterminationofnanoparticlesizeusingsingleparticleicpms AT encinarjorgeruiz relativeandtransportefficiencyindependentapproachforthedeterminationofnanoparticlesizeusingsingleparticleicpms |