Synthetic Attenuation Correction Maps for SPECT Imaging Using Deep Learning: A Study on Myocardial Perfusion Imaging

(1) Background: The CT-based attenuation correction of SPECT images is essential for obtaining accurate quantitative images in cardiovascular imaging. However, there are still many SPECT cameras without associated CT scanners throughout the world, especially in developing countries. Performing addit...

Descripción completa

Detalles Bibliográficos
Autores principales: Prieto Canalejo, Mariana Andrea, Palau San Pedro, Aley, Geronazzo, Ricardo, Minsky, Daniel Mauricio, Juárez-Orozco, Luis Eduardo, Namías, Mauro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10340370/
https://www.ncbi.nlm.nih.gov/pubmed/37443608
http://dx.doi.org/10.3390/diagnostics13132214
_version_ 1785072063057231872
author Prieto Canalejo, Mariana Andrea
Palau San Pedro, Aley
Geronazzo, Ricardo
Minsky, Daniel Mauricio
Juárez-Orozco, Luis Eduardo
Namías, Mauro
author_facet Prieto Canalejo, Mariana Andrea
Palau San Pedro, Aley
Geronazzo, Ricardo
Minsky, Daniel Mauricio
Juárez-Orozco, Luis Eduardo
Namías, Mauro
author_sort Prieto Canalejo, Mariana Andrea
collection PubMed
description (1) Background: The CT-based attenuation correction of SPECT images is essential for obtaining accurate quantitative images in cardiovascular imaging. However, there are still many SPECT cameras without associated CT scanners throughout the world, especially in developing countries. Performing additional CT scans implies troublesome planning logistics and larger radiation doses for patients, making it a suboptimal solution. Deep learning (DL) offers a revolutionary way to generate complementary images for individual patients at a large scale. Hence, we aimed to generate linear attenuation coefficient maps from SPECT emission images reconstructed without attenuation correction using deep learning. (2) Methods: A total of 384 SPECT myocardial perfusion studies that used (99m)Tc-sestamibi were included. A DL model based on a 2D U-Net architecture was trained using information from 312 patients. The quality of the generated synthetic attenuation correction maps (ACMs) and reconstructed emission values were evaluated using three metrics and compared to standard-of-care data using Bland–Altman plots. Finally, a quantitative evaluation of myocardial uptake was performed, followed by a semi-quantitative evaluation of myocardial perfusion. (3) Results: In a test set of 66 test patients, the ACM quality metrics were MSSIM = 0.97 ± 0.001 and NMAE = 3.08 ± 1.26 (%), and the reconstructed emission quality metrics were MSSIM = 0.99 ± 0.003 and NMAE = 0.23 ± 0.13 (%). The 95% limits of agreement (LoAs) at the voxel level for reconstructed SPECT images were: [−9.04; 9.00]%, and for the segment level, they were [−11; 10]%. The 95% LoAs for the Summed Stress Score values between the images reconstructed were [−2.8, 3.0]. When global perfusion scores were assessed, only 2 out of 66 patients showed changes in perfusion categories. (4) Conclusion: Deep learning can generate accurate attenuation correction maps from non-attenuation-corrected cardiac SPECT images. These high-quality attenuation maps are suitable for attenuation correction in myocardial perfusion SPECT imaging and could obviate the need for additional imaging in standalone SPECT scanners.
format Online
Article
Text
id pubmed-10340370
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103403702023-07-14 Synthetic Attenuation Correction Maps for SPECT Imaging Using Deep Learning: A Study on Myocardial Perfusion Imaging Prieto Canalejo, Mariana Andrea Palau San Pedro, Aley Geronazzo, Ricardo Minsky, Daniel Mauricio Juárez-Orozco, Luis Eduardo Namías, Mauro Diagnostics (Basel) Article (1) Background: The CT-based attenuation correction of SPECT images is essential for obtaining accurate quantitative images in cardiovascular imaging. However, there are still many SPECT cameras without associated CT scanners throughout the world, especially in developing countries. Performing additional CT scans implies troublesome planning logistics and larger radiation doses for patients, making it a suboptimal solution. Deep learning (DL) offers a revolutionary way to generate complementary images for individual patients at a large scale. Hence, we aimed to generate linear attenuation coefficient maps from SPECT emission images reconstructed without attenuation correction using deep learning. (2) Methods: A total of 384 SPECT myocardial perfusion studies that used (99m)Tc-sestamibi were included. A DL model based on a 2D U-Net architecture was trained using information from 312 patients. The quality of the generated synthetic attenuation correction maps (ACMs) and reconstructed emission values were evaluated using three metrics and compared to standard-of-care data using Bland–Altman plots. Finally, a quantitative evaluation of myocardial uptake was performed, followed by a semi-quantitative evaluation of myocardial perfusion. (3) Results: In a test set of 66 test patients, the ACM quality metrics were MSSIM = 0.97 ± 0.001 and NMAE = 3.08 ± 1.26 (%), and the reconstructed emission quality metrics were MSSIM = 0.99 ± 0.003 and NMAE = 0.23 ± 0.13 (%). The 95% limits of agreement (LoAs) at the voxel level for reconstructed SPECT images were: [−9.04; 9.00]%, and for the segment level, they were [−11; 10]%. The 95% LoAs for the Summed Stress Score values between the images reconstructed were [−2.8, 3.0]. When global perfusion scores were assessed, only 2 out of 66 patients showed changes in perfusion categories. (4) Conclusion: Deep learning can generate accurate attenuation correction maps from non-attenuation-corrected cardiac SPECT images. These high-quality attenuation maps are suitable for attenuation correction in myocardial perfusion SPECT imaging and could obviate the need for additional imaging in standalone SPECT scanners. MDPI 2023-06-29 /pmc/articles/PMC10340370/ /pubmed/37443608 http://dx.doi.org/10.3390/diagnostics13132214 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Prieto Canalejo, Mariana Andrea
Palau San Pedro, Aley
Geronazzo, Ricardo
Minsky, Daniel Mauricio
Juárez-Orozco, Luis Eduardo
Namías, Mauro
Synthetic Attenuation Correction Maps for SPECT Imaging Using Deep Learning: A Study on Myocardial Perfusion Imaging
title Synthetic Attenuation Correction Maps for SPECT Imaging Using Deep Learning: A Study on Myocardial Perfusion Imaging
title_full Synthetic Attenuation Correction Maps for SPECT Imaging Using Deep Learning: A Study on Myocardial Perfusion Imaging
title_fullStr Synthetic Attenuation Correction Maps for SPECT Imaging Using Deep Learning: A Study on Myocardial Perfusion Imaging
title_full_unstemmed Synthetic Attenuation Correction Maps for SPECT Imaging Using Deep Learning: A Study on Myocardial Perfusion Imaging
title_short Synthetic Attenuation Correction Maps for SPECT Imaging Using Deep Learning: A Study on Myocardial Perfusion Imaging
title_sort synthetic attenuation correction maps for spect imaging using deep learning: a study on myocardial perfusion imaging
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10340370/
https://www.ncbi.nlm.nih.gov/pubmed/37443608
http://dx.doi.org/10.3390/diagnostics13132214
work_keys_str_mv AT prietocanalejomarianaandrea syntheticattenuationcorrectionmapsforspectimagingusingdeeplearningastudyonmyocardialperfusionimaging
AT palausanpedroaley syntheticattenuationcorrectionmapsforspectimagingusingdeeplearningastudyonmyocardialperfusionimaging
AT geronazzoricardo syntheticattenuationcorrectionmapsforspectimagingusingdeeplearningastudyonmyocardialperfusionimaging
AT minskydanielmauricio syntheticattenuationcorrectionmapsforspectimagingusingdeeplearningastudyonmyocardialperfusionimaging
AT juarezorozcoluiseduardo syntheticattenuationcorrectionmapsforspectimagingusingdeeplearningastudyonmyocardialperfusionimaging
AT namiasmauro syntheticattenuationcorrectionmapsforspectimagingusingdeeplearningastudyonmyocardialperfusionimaging