Cargando…
Prospects of Endovenous Laser Ablation (EVLA) Standardization—Mid-Term Results of a Four-Zone Dosimetry Guiding Tool for 1940 nm Laser
Background: Heterogeneity regarding dosimetry and reporting of endovenous laser ablation (EVLA) mandates the development of a standardized protocol. This study presents the mid-term results of EVLA with 1940 nm-laser and radial-fibre, supported by a four-zone dosimetry tool. Materials and methods: F...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10342372/ https://www.ncbi.nlm.nih.gov/pubmed/37445351 http://dx.doi.org/10.3390/jcm12134313 |
_version_ | 1785072483362144256 |
---|---|
author | Setia, Abhay Dikic, Slobodan Demhasaj, Sahit Schmitz-Rixen, Thomas Sroka, Ronald Schmedt, Claus-Georg |
author_facet | Setia, Abhay Dikic, Slobodan Demhasaj, Sahit Schmitz-Rixen, Thomas Sroka, Ronald Schmedt, Claus-Georg |
author_sort | Setia, Abhay |
collection | PubMed |
description | Background: Heterogeneity regarding dosimetry and reporting of endovenous laser ablation (EVLA) mandates the development of a standardized protocol. This study presents the mid-term results of EVLA with 1940 nm-laser and radial-fibre, supported by a four-zone dosimetry tool. Materials and methods: Four anatomical dosimetry zones for great saphenous veins (GSV) and two for small saphenous veins (SSV) were defined with set power levels. Zone-1G (4 W) extended from the inguinal ligament to the apex of femoral triangle, Zone-2G (4 W) from the apex of femoral triangle to the upper border of patella. Zone-3G (3 W) from the patella to the tibial tuberosity. Zone-4G (2 W) extended from the tibial tuberosity to the ankle. Zone-1S from the sapheno-popliteal junction to the tibial tuberosity. Zone-2S from the tibial tuberosity to the ankle. Power was increased by 1 W for veins >10 mm and decreased by 1 W when fibre sticking was encountered. Pullback-velocity was max. 1 mm/s. Results: A total of 152 consecutive patients (185 procedures) were recruited. Mean follow-up time was 11.9 months. Mean linear endovenous energy density for GSV was Zone-1G:42 J/cm, Zone-2G:33 J/cm, Zone-3G:27 J/cm, Zone-4G:22 J/cm, Zone-1S:34 J/cm, Zone-2S:27 J/cm. Occlusion rates were 98.9% (1-month) and 93.7% (12-months). Complications at 1 M were low, namely laser-induced paraesthesia (LIP) 2.2% and endovenous heat-induced thrombosis (EHIT) 1.6%. Persistent LIP (12 M) was observed in 0.5%. Conclusion: The proposed four-zone guiding tool is a step towards standardizing dosimetry and documentation for EVLA with 1940 nm. This strategy shows good mid-term results with minimal complications. Long-term follow-up and application in further centres are necessary to prove its reproducibility. Such a guiding tool could improve the ability to analyse, compare and review different EVLA wavelengths and fibre types. |
format | Online Article Text |
id | pubmed-10342372 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103423722023-07-14 Prospects of Endovenous Laser Ablation (EVLA) Standardization—Mid-Term Results of a Four-Zone Dosimetry Guiding Tool for 1940 nm Laser Setia, Abhay Dikic, Slobodan Demhasaj, Sahit Schmitz-Rixen, Thomas Sroka, Ronald Schmedt, Claus-Georg J Clin Med Article Background: Heterogeneity regarding dosimetry and reporting of endovenous laser ablation (EVLA) mandates the development of a standardized protocol. This study presents the mid-term results of EVLA with 1940 nm-laser and radial-fibre, supported by a four-zone dosimetry tool. Materials and methods: Four anatomical dosimetry zones for great saphenous veins (GSV) and two for small saphenous veins (SSV) were defined with set power levels. Zone-1G (4 W) extended from the inguinal ligament to the apex of femoral triangle, Zone-2G (4 W) from the apex of femoral triangle to the upper border of patella. Zone-3G (3 W) from the patella to the tibial tuberosity. Zone-4G (2 W) extended from the tibial tuberosity to the ankle. Zone-1S from the sapheno-popliteal junction to the tibial tuberosity. Zone-2S from the tibial tuberosity to the ankle. Power was increased by 1 W for veins >10 mm and decreased by 1 W when fibre sticking was encountered. Pullback-velocity was max. 1 mm/s. Results: A total of 152 consecutive patients (185 procedures) were recruited. Mean follow-up time was 11.9 months. Mean linear endovenous energy density for GSV was Zone-1G:42 J/cm, Zone-2G:33 J/cm, Zone-3G:27 J/cm, Zone-4G:22 J/cm, Zone-1S:34 J/cm, Zone-2S:27 J/cm. Occlusion rates were 98.9% (1-month) and 93.7% (12-months). Complications at 1 M were low, namely laser-induced paraesthesia (LIP) 2.2% and endovenous heat-induced thrombosis (EHIT) 1.6%. Persistent LIP (12 M) was observed in 0.5%. Conclusion: The proposed four-zone guiding tool is a step towards standardizing dosimetry and documentation for EVLA with 1940 nm. This strategy shows good mid-term results with minimal complications. Long-term follow-up and application in further centres are necessary to prove its reproducibility. Such a guiding tool could improve the ability to analyse, compare and review different EVLA wavelengths and fibre types. MDPI 2023-06-27 /pmc/articles/PMC10342372/ /pubmed/37445351 http://dx.doi.org/10.3390/jcm12134313 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Setia, Abhay Dikic, Slobodan Demhasaj, Sahit Schmitz-Rixen, Thomas Sroka, Ronald Schmedt, Claus-Georg Prospects of Endovenous Laser Ablation (EVLA) Standardization—Mid-Term Results of a Four-Zone Dosimetry Guiding Tool for 1940 nm Laser |
title | Prospects of Endovenous Laser Ablation (EVLA) Standardization—Mid-Term Results of a Four-Zone Dosimetry Guiding Tool for 1940 nm Laser |
title_full | Prospects of Endovenous Laser Ablation (EVLA) Standardization—Mid-Term Results of a Four-Zone Dosimetry Guiding Tool for 1940 nm Laser |
title_fullStr | Prospects of Endovenous Laser Ablation (EVLA) Standardization—Mid-Term Results of a Four-Zone Dosimetry Guiding Tool for 1940 nm Laser |
title_full_unstemmed | Prospects of Endovenous Laser Ablation (EVLA) Standardization—Mid-Term Results of a Four-Zone Dosimetry Guiding Tool for 1940 nm Laser |
title_short | Prospects of Endovenous Laser Ablation (EVLA) Standardization—Mid-Term Results of a Four-Zone Dosimetry Guiding Tool for 1940 nm Laser |
title_sort | prospects of endovenous laser ablation (evla) standardization—mid-term results of a four-zone dosimetry guiding tool for 1940 nm laser |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10342372/ https://www.ncbi.nlm.nih.gov/pubmed/37445351 http://dx.doi.org/10.3390/jcm12134313 |
work_keys_str_mv | AT setiaabhay prospectsofendovenouslaserablationevlastandardizationmidtermresultsofafourzonedosimetryguidingtoolfor1940nmlaser AT dikicslobodan prospectsofendovenouslaserablationevlastandardizationmidtermresultsofafourzonedosimetryguidingtoolfor1940nmlaser AT demhasajsahit prospectsofendovenouslaserablationevlastandardizationmidtermresultsofafourzonedosimetryguidingtoolfor1940nmlaser AT schmitzrixenthomas prospectsofendovenouslaserablationevlastandardizationmidtermresultsofafourzonedosimetryguidingtoolfor1940nmlaser AT srokaronald prospectsofendovenouslaserablationevlastandardizationmidtermresultsofafourzonedosimetryguidingtoolfor1940nmlaser AT schmedtclausgeorg prospectsofendovenouslaserablationevlastandardizationmidtermresultsofafourzonedosimetryguidingtoolfor1940nmlaser |