Cargando…

Highly Sensitive Detection of Microstructure Variation Using a Thickness Resonant Transducer and Pulse-Echo Third Harmonic Generation

In nonlinear ultrasound testing, the relative nonlinear parameter is conveniently measured as a sensitive means of detecting and imaging overall variation of microstructures and damages. Compared to the quadratic nonlinear parameter ([Formula: see text]), the cubic nonlinear parameter ([Formula: see...

Descripción completa

Detalles Bibliográficos
Autores principales: Jeong, Hyunjo, Shin, Hyojeong, Zhang, Shuzeng, Li, Xiongbing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10342890/
https://www.ncbi.nlm.nih.gov/pubmed/37445053
http://dx.doi.org/10.3390/ma16134739
_version_ 1785072607438045184
author Jeong, Hyunjo
Shin, Hyojeong
Zhang, Shuzeng
Li, Xiongbing
author_facet Jeong, Hyunjo
Shin, Hyojeong
Zhang, Shuzeng
Li, Xiongbing
author_sort Jeong, Hyunjo
collection PubMed
description In nonlinear ultrasound testing, the relative nonlinear parameter is conveniently measured as a sensitive means of detecting and imaging overall variation of microstructures and damages. Compared to the quadratic nonlinear parameter ([Formula: see text]), the cubic nonlinear parameter ([Formula: see text]), calculated as the third harmonic amplitude divided by the cube of the fundamental amplitude, has generally a higher value, providing better sensitivity in nonlinear parameter mapping. Since the third harmonic amplitude is about two orders of magnitude lower than the fundamental amplitude, efficient excitation and highly sensitive reception of third harmonic is very important. In this paper, we explore an odd harmonic thickness resonant transducer that meets the requirements for pulse-echo third harmonic generation (THG) measurements. We also address the problem of source nonlinearity that may be present in the measured amplitude of the third harmonic and propose a method to properly correct it. First, we measure [Formula: see text] for a series of aluminum specimens using the through-transmission method to observe the behavior of [Formula: see text] as a function of specimen thickness and input voltage, and examine the effects of various corrections such as attenuation, diffraction and source nonlinearity. Next, we apply the odd harmonic resonant transducer to pulse-echo THG measurements of precipitation heat-treated specimens. It is shown that such transducer is very effective in generation and detection of fundamental and third harmonics under finite amplitude toneburst excitation. The highly sensitive detectability of [Formula: see text] are presented as a function of aging time, and the sensitivity of [Formula: see text] is compared with that of [Formula: see text] and [Formula: see text].
format Online
Article
Text
id pubmed-10342890
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103428902023-07-14 Highly Sensitive Detection of Microstructure Variation Using a Thickness Resonant Transducer and Pulse-Echo Third Harmonic Generation Jeong, Hyunjo Shin, Hyojeong Zhang, Shuzeng Li, Xiongbing Materials (Basel) Article In nonlinear ultrasound testing, the relative nonlinear parameter is conveniently measured as a sensitive means of detecting and imaging overall variation of microstructures and damages. Compared to the quadratic nonlinear parameter ([Formula: see text]), the cubic nonlinear parameter ([Formula: see text]), calculated as the third harmonic amplitude divided by the cube of the fundamental amplitude, has generally a higher value, providing better sensitivity in nonlinear parameter mapping. Since the third harmonic amplitude is about two orders of magnitude lower than the fundamental amplitude, efficient excitation and highly sensitive reception of third harmonic is very important. In this paper, we explore an odd harmonic thickness resonant transducer that meets the requirements for pulse-echo third harmonic generation (THG) measurements. We also address the problem of source nonlinearity that may be present in the measured amplitude of the third harmonic and propose a method to properly correct it. First, we measure [Formula: see text] for a series of aluminum specimens using the through-transmission method to observe the behavior of [Formula: see text] as a function of specimen thickness and input voltage, and examine the effects of various corrections such as attenuation, diffraction and source nonlinearity. Next, we apply the odd harmonic resonant transducer to pulse-echo THG measurements of precipitation heat-treated specimens. It is shown that such transducer is very effective in generation and detection of fundamental and third harmonics under finite amplitude toneburst excitation. The highly sensitive detectability of [Formula: see text] are presented as a function of aging time, and the sensitivity of [Formula: see text] is compared with that of [Formula: see text] and [Formula: see text]. MDPI 2023-06-30 /pmc/articles/PMC10342890/ /pubmed/37445053 http://dx.doi.org/10.3390/ma16134739 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jeong, Hyunjo
Shin, Hyojeong
Zhang, Shuzeng
Li, Xiongbing
Highly Sensitive Detection of Microstructure Variation Using a Thickness Resonant Transducer and Pulse-Echo Third Harmonic Generation
title Highly Sensitive Detection of Microstructure Variation Using a Thickness Resonant Transducer and Pulse-Echo Third Harmonic Generation
title_full Highly Sensitive Detection of Microstructure Variation Using a Thickness Resonant Transducer and Pulse-Echo Third Harmonic Generation
title_fullStr Highly Sensitive Detection of Microstructure Variation Using a Thickness Resonant Transducer and Pulse-Echo Third Harmonic Generation
title_full_unstemmed Highly Sensitive Detection of Microstructure Variation Using a Thickness Resonant Transducer and Pulse-Echo Third Harmonic Generation
title_short Highly Sensitive Detection of Microstructure Variation Using a Thickness Resonant Transducer and Pulse-Echo Third Harmonic Generation
title_sort highly sensitive detection of microstructure variation using a thickness resonant transducer and pulse-echo third harmonic generation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10342890/
https://www.ncbi.nlm.nih.gov/pubmed/37445053
http://dx.doi.org/10.3390/ma16134739
work_keys_str_mv AT jeonghyunjo highlysensitivedetectionofmicrostructurevariationusingathicknessresonanttransducerandpulseechothirdharmonicgeneration
AT shinhyojeong highlysensitivedetectionofmicrostructurevariationusingathicknessresonanttransducerandpulseechothirdharmonicgeneration
AT zhangshuzeng highlysensitivedetectionofmicrostructurevariationusingathicknessresonanttransducerandpulseechothirdharmonicgeneration
AT lixiongbing highlysensitivedetectionofmicrostructurevariationusingathicknessresonanttransducerandpulseechothirdharmonicgeneration