Cargando…

A Modified Single-Armed Suture Technique for Traumatic Cyclodialysis Cleft with Vitreoretinal Injury

Our aim was to assess the therapeutic efficacy of a modified single-arm suture technique on traumatic cyclodialysis cleft with vitreoretinal injury. The procedure involved fixing a detached ciliary body using a single-armed 10-0 polypropylene suture under the assistance of a 29-gauge needle. Patient...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Xueyong, Wang, Nan, Zheng, Guoli, Liu, Die, Zhang, Quyan, Lei, Wenbo, Xia, Xiaobo, Xiong, Siqi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10342938/
https://www.ncbi.nlm.nih.gov/pubmed/37445287
http://dx.doi.org/10.3390/jcm12134252
_version_ 1785072618585456640
author Zhang, Xueyong
Wang, Nan
Zheng, Guoli
Liu, Die
Zhang, Quyan
Lei, Wenbo
Xia, Xiaobo
Xiong, Siqi
author_facet Zhang, Xueyong
Wang, Nan
Zheng, Guoli
Liu, Die
Zhang, Quyan
Lei, Wenbo
Xia, Xiaobo
Xiong, Siqi
author_sort Zhang, Xueyong
collection PubMed
description Our aim was to assess the therapeutic efficacy of a modified single-arm suture technique on traumatic cyclodialysis cleft with vitreoretinal injury. The procedure involved fixing a detached ciliary body using a single-armed 10-0 polypropylene suture under the assistance of a 29-gauge needle. Patients with a traumatic cyclodialysis cleft combined with an anterior and posterior segment injury who underwent modified internal cyclopexy together with vitreoretinal surgery were enrolled in this study. Ultrasound biomicroscopy (UBM) was used to diagnose and evaluate the cyclodialysis and anterior segment injury. B-scan ultrasonography was performed to assess the condition of the vitreous, retina and choroid. The surgical time and successful rate for repairing the cyclodialysis cleft were recorded. Preoperative and postoperative best-corrected visual acuity (BCVA), and intraocular pressure (IOP) were documented for assessment. The study included 20 eyes. The extent of the cyclodialysis cleft was from 30° to 360°. Besides a traumatic cyclodialysis cleft, the included cases also combined this with vitreous hemorrhages, retinal detachment, macular holes, choroid avulsion, and suprachoroidal hemorrhage. All the clefts were anatomically closed in one surgery. The average surgical time for fixing the cyclodialysis cleft was 2.68 ± 0.54 min/30° cleft. A significant improvement in LogMAR BCVA was observed from 2.94 ± 0.93 preoperatively to 1.81 ± 1.11 at the 6-month follow-up. IOP was elevated from 10.90 ± 6.18 mmHg preoperatively to 14.45 ± 2.35 mmHg at the 6-month follow-up. The modified single-armed suture technique was proved to be an effective method to fix the traumatic cyclodialysis cleft, which could facilitate the use of the procedure to repair chorioretinal disorders. It improved the BCVA and maintained the IOP with less postoperative complications.
format Online
Article
Text
id pubmed-10342938
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103429382023-07-14 A Modified Single-Armed Suture Technique for Traumatic Cyclodialysis Cleft with Vitreoretinal Injury Zhang, Xueyong Wang, Nan Zheng, Guoli Liu, Die Zhang, Quyan Lei, Wenbo Xia, Xiaobo Xiong, Siqi J Clin Med Article Our aim was to assess the therapeutic efficacy of a modified single-arm suture technique on traumatic cyclodialysis cleft with vitreoretinal injury. The procedure involved fixing a detached ciliary body using a single-armed 10-0 polypropylene suture under the assistance of a 29-gauge needle. Patients with a traumatic cyclodialysis cleft combined with an anterior and posterior segment injury who underwent modified internal cyclopexy together with vitreoretinal surgery were enrolled in this study. Ultrasound biomicroscopy (UBM) was used to diagnose and evaluate the cyclodialysis and anterior segment injury. B-scan ultrasonography was performed to assess the condition of the vitreous, retina and choroid. The surgical time and successful rate for repairing the cyclodialysis cleft were recorded. Preoperative and postoperative best-corrected visual acuity (BCVA), and intraocular pressure (IOP) were documented for assessment. The study included 20 eyes. The extent of the cyclodialysis cleft was from 30° to 360°. Besides a traumatic cyclodialysis cleft, the included cases also combined this with vitreous hemorrhages, retinal detachment, macular holes, choroid avulsion, and suprachoroidal hemorrhage. All the clefts were anatomically closed in one surgery. The average surgical time for fixing the cyclodialysis cleft was 2.68 ± 0.54 min/30° cleft. A significant improvement in LogMAR BCVA was observed from 2.94 ± 0.93 preoperatively to 1.81 ± 1.11 at the 6-month follow-up. IOP was elevated from 10.90 ± 6.18 mmHg preoperatively to 14.45 ± 2.35 mmHg at the 6-month follow-up. The modified single-armed suture technique was proved to be an effective method to fix the traumatic cyclodialysis cleft, which could facilitate the use of the procedure to repair chorioretinal disorders. It improved the BCVA and maintained the IOP with less postoperative complications. MDPI 2023-06-25 /pmc/articles/PMC10342938/ /pubmed/37445287 http://dx.doi.org/10.3390/jcm12134252 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhang, Xueyong
Wang, Nan
Zheng, Guoli
Liu, Die
Zhang, Quyan
Lei, Wenbo
Xia, Xiaobo
Xiong, Siqi
A Modified Single-Armed Suture Technique for Traumatic Cyclodialysis Cleft with Vitreoretinal Injury
title A Modified Single-Armed Suture Technique for Traumatic Cyclodialysis Cleft with Vitreoretinal Injury
title_full A Modified Single-Armed Suture Technique for Traumatic Cyclodialysis Cleft with Vitreoretinal Injury
title_fullStr A Modified Single-Armed Suture Technique for Traumatic Cyclodialysis Cleft with Vitreoretinal Injury
title_full_unstemmed A Modified Single-Armed Suture Technique for Traumatic Cyclodialysis Cleft with Vitreoretinal Injury
title_short A Modified Single-Armed Suture Technique for Traumatic Cyclodialysis Cleft with Vitreoretinal Injury
title_sort modified single-armed suture technique for traumatic cyclodialysis cleft with vitreoretinal injury
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10342938/
https://www.ncbi.nlm.nih.gov/pubmed/37445287
http://dx.doi.org/10.3390/jcm12134252
work_keys_str_mv AT zhangxueyong amodifiedsinglearmedsuturetechniquefortraumaticcyclodialysiscleftwithvitreoretinalinjury
AT wangnan amodifiedsinglearmedsuturetechniquefortraumaticcyclodialysiscleftwithvitreoretinalinjury
AT zhengguoli amodifiedsinglearmedsuturetechniquefortraumaticcyclodialysiscleftwithvitreoretinalinjury
AT liudie amodifiedsinglearmedsuturetechniquefortraumaticcyclodialysiscleftwithvitreoretinalinjury
AT zhangquyan amodifiedsinglearmedsuturetechniquefortraumaticcyclodialysiscleftwithvitreoretinalinjury
AT leiwenbo amodifiedsinglearmedsuturetechniquefortraumaticcyclodialysiscleftwithvitreoretinalinjury
AT xiaxiaobo amodifiedsinglearmedsuturetechniquefortraumaticcyclodialysiscleftwithvitreoretinalinjury
AT xiongsiqi amodifiedsinglearmedsuturetechniquefortraumaticcyclodialysiscleftwithvitreoretinalinjury
AT zhangxueyong modifiedsinglearmedsuturetechniquefortraumaticcyclodialysiscleftwithvitreoretinalinjury
AT wangnan modifiedsinglearmedsuturetechniquefortraumaticcyclodialysiscleftwithvitreoretinalinjury
AT zhengguoli modifiedsinglearmedsuturetechniquefortraumaticcyclodialysiscleftwithvitreoretinalinjury
AT liudie modifiedsinglearmedsuturetechniquefortraumaticcyclodialysiscleftwithvitreoretinalinjury
AT zhangquyan modifiedsinglearmedsuturetechniquefortraumaticcyclodialysiscleftwithvitreoretinalinjury
AT leiwenbo modifiedsinglearmedsuturetechniquefortraumaticcyclodialysiscleftwithvitreoretinalinjury
AT xiaxiaobo modifiedsinglearmedsuturetechniquefortraumaticcyclodialysiscleftwithvitreoretinalinjury
AT xiongsiqi modifiedsinglearmedsuturetechniquefortraumaticcyclodialysiscleftwithvitreoretinalinjury