Cargando…

Fabrication and Applications of Potentiometric Membrane Sensors Based on Specific Recognition Sites for the Measurement of the Quinolone Antibacterial Drug Gemifloxacin

Supramolecular gemifloxacin (GF) sensors have been developed. Supramolecular chemistry is primarily concerned with noncovalent intermolecular and intramolecular interactions, which are far weaker than covalent connections, but they can be exploited to develop sensors with remarkable affinity for a t...

Descripción completa

Detalles Bibliográficos
Autores principales: Mostafa, Gamal A.E., Ali, Essam A., Alsalahi, Rashad A., Alrabiah, Haitham
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10343349/
https://www.ncbi.nlm.nih.gov/pubmed/37446807
http://dx.doi.org/10.3390/molecules28135144
_version_ 1785072715940495360
author Mostafa, Gamal A.E.
Ali, Essam A.
Alsalahi, Rashad A.
Alrabiah, Haitham
author_facet Mostafa, Gamal A.E.
Ali, Essam A.
Alsalahi, Rashad A.
Alrabiah, Haitham
author_sort Mostafa, Gamal A.E.
collection PubMed
description Supramolecular gemifloxacin (GF) sensors have been developed. Supramolecular chemistry is primarily concerned with noncovalent intermolecular and intramolecular interactions, which are far weaker than covalent connections, but they can be exploited to develop sensors with remarkable affinity for a target analyte. In order to determine the dose form of the quinolone antibacterial drug gemifloxacin, the current study’s goal is to adapt three polyvinylchloride (PVC) membrane sensors into an electrochemical technique. Three new potentiometric membrane sensors with cylindric form and responsive to gemifloxacin (GF) were developed. The sensors’ setup is based on the usage of o-nitrophenyl octyl ether (o-NPOE) as a plasticizer in a PVC matrix, β-cyclodextrin (β-CD) (sensor 1), γ-cyclodextrin (γ-CD) (sensor 2), and 4-tert-butylcalix[8]arene (calixarene) (sensor 3) as an ionophore, potassium tetrakis (4-chlorophenyl) borate (KTpClPB) as an ion additive for determination of GF. The developed method was verified according to IUPAC guidelines. The sensors under examination have good selectivity for GF, according to their selectivity coefficients. The constructed sensors demonstrated a significant response towards to GF over a concentration range of 2.4 × 10(−6), 2.7 × 10(−6), and 2.42 × 10(−6) mol L(−1) for sensors 1, 2, and 3, respectively. The sensors showed near-Nernstian cationic response for GF at 55 mV, 56 mV, and 60 mV per decade for sensors 1, 2, and 3, respectively. Good recovery and relative standard deviations during the day and between days are displayed by the sensors. They demonstrated good stability, quick response times, long lives, rapid recovery, and precision while also exhibiting good selectivity for GF in various matrices. To determine GF in bulk and dose form, the developed sensors have been successfully deployed. The sensors were also employed as end-point indicators for titrating GF with sodium tetraphenyl borate.
format Online
Article
Text
id pubmed-10343349
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103433492023-07-14 Fabrication and Applications of Potentiometric Membrane Sensors Based on Specific Recognition Sites for the Measurement of the Quinolone Antibacterial Drug Gemifloxacin Mostafa, Gamal A.E. Ali, Essam A. Alsalahi, Rashad A. Alrabiah, Haitham Molecules Article Supramolecular gemifloxacin (GF) sensors have been developed. Supramolecular chemistry is primarily concerned with noncovalent intermolecular and intramolecular interactions, which are far weaker than covalent connections, but they can be exploited to develop sensors with remarkable affinity for a target analyte. In order to determine the dose form of the quinolone antibacterial drug gemifloxacin, the current study’s goal is to adapt three polyvinylchloride (PVC) membrane sensors into an electrochemical technique. Three new potentiometric membrane sensors with cylindric form and responsive to gemifloxacin (GF) were developed. The sensors’ setup is based on the usage of o-nitrophenyl octyl ether (o-NPOE) as a plasticizer in a PVC matrix, β-cyclodextrin (β-CD) (sensor 1), γ-cyclodextrin (γ-CD) (sensor 2), and 4-tert-butylcalix[8]arene (calixarene) (sensor 3) as an ionophore, potassium tetrakis (4-chlorophenyl) borate (KTpClPB) as an ion additive for determination of GF. The developed method was verified according to IUPAC guidelines. The sensors under examination have good selectivity for GF, according to their selectivity coefficients. The constructed sensors demonstrated a significant response towards to GF over a concentration range of 2.4 × 10(−6), 2.7 × 10(−6), and 2.42 × 10(−6) mol L(−1) for sensors 1, 2, and 3, respectively. The sensors showed near-Nernstian cationic response for GF at 55 mV, 56 mV, and 60 mV per decade for sensors 1, 2, and 3, respectively. Good recovery and relative standard deviations during the day and between days are displayed by the sensors. They demonstrated good stability, quick response times, long lives, rapid recovery, and precision while also exhibiting good selectivity for GF in various matrices. To determine GF in bulk and dose form, the developed sensors have been successfully deployed. The sensors were also employed as end-point indicators for titrating GF with sodium tetraphenyl borate. MDPI 2023-06-30 /pmc/articles/PMC10343349/ /pubmed/37446807 http://dx.doi.org/10.3390/molecules28135144 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mostafa, Gamal A.E.
Ali, Essam A.
Alsalahi, Rashad A.
Alrabiah, Haitham
Fabrication and Applications of Potentiometric Membrane Sensors Based on Specific Recognition Sites for the Measurement of the Quinolone Antibacterial Drug Gemifloxacin
title Fabrication and Applications of Potentiometric Membrane Sensors Based on Specific Recognition Sites for the Measurement of the Quinolone Antibacterial Drug Gemifloxacin
title_full Fabrication and Applications of Potentiometric Membrane Sensors Based on Specific Recognition Sites for the Measurement of the Quinolone Antibacterial Drug Gemifloxacin
title_fullStr Fabrication and Applications of Potentiometric Membrane Sensors Based on Specific Recognition Sites for the Measurement of the Quinolone Antibacterial Drug Gemifloxacin
title_full_unstemmed Fabrication and Applications of Potentiometric Membrane Sensors Based on Specific Recognition Sites for the Measurement of the Quinolone Antibacterial Drug Gemifloxacin
title_short Fabrication and Applications of Potentiometric Membrane Sensors Based on Specific Recognition Sites for the Measurement of the Quinolone Antibacterial Drug Gemifloxacin
title_sort fabrication and applications of potentiometric membrane sensors based on specific recognition sites for the measurement of the quinolone antibacterial drug gemifloxacin
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10343349/
https://www.ncbi.nlm.nih.gov/pubmed/37446807
http://dx.doi.org/10.3390/molecules28135144
work_keys_str_mv AT mostafagamalae fabricationandapplicationsofpotentiometricmembranesensorsbasedonspecificrecognitionsitesforthemeasurementofthequinoloneantibacterialdruggemifloxacin
AT aliessama fabricationandapplicationsofpotentiometricmembranesensorsbasedonspecificrecognitionsitesforthemeasurementofthequinoloneantibacterialdruggemifloxacin
AT alsalahirashada fabricationandapplicationsofpotentiometricmembranesensorsbasedonspecificrecognitionsitesforthemeasurementofthequinoloneantibacterialdruggemifloxacin
AT alrabiahhaitham fabricationandapplicationsofpotentiometricmembranesensorsbasedonspecificrecognitionsitesforthemeasurementofthequinoloneantibacterialdruggemifloxacin