Cargando…
Development of a Long-Term Sampling Method for Determination of NMHCs in Indoor Air
Vapor intrusion is detrimental for indoor air quality. One of the most common sources of vapor intrusion is soil contaminated with petroleum hydrocarbons. To evaluate the long-term risk from individual exposure to hydrocarbons it is necessary to measure quantitively and reliably an average concentra...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10343520/ https://www.ncbi.nlm.nih.gov/pubmed/37446664 http://dx.doi.org/10.3390/molecules28135001 |
_version_ | 1785072756531920896 |
---|---|
author | Urupina, Darya Traverse, Sylvie Leonardis, Thierry Eymard-Vernain, Elise Guilhermet, Julien Ricard, Vincent Lemoine, Marie Varlet, Camille Gillet, Remy Locoge, Nadine |
author_facet | Urupina, Darya Traverse, Sylvie Leonardis, Thierry Eymard-Vernain, Elise Guilhermet, Julien Ricard, Vincent Lemoine, Marie Varlet, Camille Gillet, Remy Locoge, Nadine |
author_sort | Urupina, Darya |
collection | PubMed |
description | Vapor intrusion is detrimental for indoor air quality. One of the most common sources of vapor intrusion is soil contaminated with petroleum hydrocarbons. To evaluate the long-term risk from individual exposure to hydrocarbons it is necessary to measure quantitively and reliably an average concentration level of individual pollutants on a monthly or yearly basis. Temporal variability of vapor intrusion from hydrocarbons poses a significant challenge to determination of average exposure and there is a need for reliable long-term integrative sampling. To this end, an analytical method for determination of 10 selected nonmethane hydrocarbons (NMHCs), including hexane, heptane, octane, decane, benzene, toluene, ethyl-benzene, m,p-xylene, o-xylene, and naphthalene, sampled on active triple-bed tubes filled with Carbograph 2, Carbograph 1, and Carboxen 1003 adsorbents was developed and validated. Extensive laboratory studies proved the absence of breakthrough at 50% HR and ambient temperature for experiments lasting up to 28 days and established a safe sampling time/volume of 20 days/114 L when sampling at a low flow rate of around 4 mL min(−1). In addition, the developed method includes detailed uncertainty calculations for determination of concentrations. Finally, the method was tested by measuring NMHC concentrations in indoor air at a former industrial site during a 2-month-long field campaign in Lyon. The results of the field campaign suggest that 4-week integrated concentration measurements can be achieved by using active sampling on triple-bed tubes at 4.5 mL min(−1). |
format | Online Article Text |
id | pubmed-10343520 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103435202023-07-14 Development of a Long-Term Sampling Method for Determination of NMHCs in Indoor Air Urupina, Darya Traverse, Sylvie Leonardis, Thierry Eymard-Vernain, Elise Guilhermet, Julien Ricard, Vincent Lemoine, Marie Varlet, Camille Gillet, Remy Locoge, Nadine Molecules Article Vapor intrusion is detrimental for indoor air quality. One of the most common sources of vapor intrusion is soil contaminated with petroleum hydrocarbons. To evaluate the long-term risk from individual exposure to hydrocarbons it is necessary to measure quantitively and reliably an average concentration level of individual pollutants on a monthly or yearly basis. Temporal variability of vapor intrusion from hydrocarbons poses a significant challenge to determination of average exposure and there is a need for reliable long-term integrative sampling. To this end, an analytical method for determination of 10 selected nonmethane hydrocarbons (NMHCs), including hexane, heptane, octane, decane, benzene, toluene, ethyl-benzene, m,p-xylene, o-xylene, and naphthalene, sampled on active triple-bed tubes filled with Carbograph 2, Carbograph 1, and Carboxen 1003 adsorbents was developed and validated. Extensive laboratory studies proved the absence of breakthrough at 50% HR and ambient temperature for experiments lasting up to 28 days and established a safe sampling time/volume of 20 days/114 L when sampling at a low flow rate of around 4 mL min(−1). In addition, the developed method includes detailed uncertainty calculations for determination of concentrations. Finally, the method was tested by measuring NMHC concentrations in indoor air at a former industrial site during a 2-month-long field campaign in Lyon. The results of the field campaign suggest that 4-week integrated concentration measurements can be achieved by using active sampling on triple-bed tubes at 4.5 mL min(−1). MDPI 2023-06-26 /pmc/articles/PMC10343520/ /pubmed/37446664 http://dx.doi.org/10.3390/molecules28135001 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Urupina, Darya Traverse, Sylvie Leonardis, Thierry Eymard-Vernain, Elise Guilhermet, Julien Ricard, Vincent Lemoine, Marie Varlet, Camille Gillet, Remy Locoge, Nadine Development of a Long-Term Sampling Method for Determination of NMHCs in Indoor Air |
title | Development of a Long-Term Sampling Method for Determination of NMHCs in Indoor Air |
title_full | Development of a Long-Term Sampling Method for Determination of NMHCs in Indoor Air |
title_fullStr | Development of a Long-Term Sampling Method for Determination of NMHCs in Indoor Air |
title_full_unstemmed | Development of a Long-Term Sampling Method for Determination of NMHCs in Indoor Air |
title_short | Development of a Long-Term Sampling Method for Determination of NMHCs in Indoor Air |
title_sort | development of a long-term sampling method for determination of nmhcs in indoor air |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10343520/ https://www.ncbi.nlm.nih.gov/pubmed/37446664 http://dx.doi.org/10.3390/molecules28135001 |
work_keys_str_mv | AT urupinadarya developmentofalongtermsamplingmethodfordeterminationofnmhcsinindoorair AT traversesylvie developmentofalongtermsamplingmethodfordeterminationofnmhcsinindoorair AT leonardisthierry developmentofalongtermsamplingmethodfordeterminationofnmhcsinindoorair AT eymardvernainelise developmentofalongtermsamplingmethodfordeterminationofnmhcsinindoorair AT guilhermetjulien developmentofalongtermsamplingmethodfordeterminationofnmhcsinindoorair AT ricardvincent developmentofalongtermsamplingmethodfordeterminationofnmhcsinindoorair AT lemoinemarie developmentofalongtermsamplingmethodfordeterminationofnmhcsinindoorair AT varletcamille developmentofalongtermsamplingmethodfordeterminationofnmhcsinindoorair AT gilletremy developmentofalongtermsamplingmethodfordeterminationofnmhcsinindoorair AT locogenadine developmentofalongtermsamplingmethodfordeterminationofnmhcsinindoorair |