Cargando…
Mapping estimates of vascular permeability with a clinical indocyanine green fluorescence imaging system in experimental pancreatic adenocarcinoma tumors
SIGNIFICANCE: Pancreatic cancer tumors are known to be avascular, but their neovascular capillaries are still chaotic leaky vessels. Capillary permeability could have significant value for therapy assessment, and its quantification might be possible with macroscopic imaging of indocyanine green (ICG...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Society of Photo-Optical Instrumentation Engineers
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10344470/ https://www.ncbi.nlm.nih.gov/pubmed/37457627 http://dx.doi.org/10.1117/1.JBO.28.7.076001 |
_version_ | 1785072875375427584 |
---|---|
author | Reed, Matthew S. Ochoa, Marien Tichauer, Kenneth M. Weichmann, Ashley Doyley, Marvin M. Pogue, Brian W. |
author_facet | Reed, Matthew S. Ochoa, Marien Tichauer, Kenneth M. Weichmann, Ashley Doyley, Marvin M. Pogue, Brian W. |
author_sort | Reed, Matthew S. |
collection | PubMed |
description | SIGNIFICANCE: Pancreatic cancer tumors are known to be avascular, but their neovascular capillaries are still chaotic leaky vessels. Capillary permeability could have significant value for therapy assessment, and its quantification might be possible with macroscopic imaging of indocyanine green (ICG) kinetics in tissue. AIM: The capacity of using standard fluorescence surgical systems for ICG kinetic imaging as a probe for capillary leakage was evaluated using a clinical surgical fluorescence imaging system, as interpreted through vascular permeability modeling. APPROACH: Xenograft pancreatic adenocarcinoma models were imaged in mice during bolus injection of ICG to capture the kinetics of uptake. Image analysis included ratiometric data, normalization, and match to theoretical modeling. Kinetic data were converted into the extraction fraction of the capillary leakage. RESULTS: Pancreatic tumors were usually less fluorescent than the surrounding healthy tissues, but still the rate of tumor perfusion could be assessed to quantify capillary extraction. Model simulations showed that flow kinetics stabilized after about 1 min beyond the initial bolus injection and that the relative extraction fraction model estimates matched the experimental data of normalized uptake within the tissue. The kinetics in the time period of 1 to 2 min post-injection provided optimal differential data between AsPC1 and BxPC3 tumors, although high individual variation exists between tumors. CONCLUSIONS: ICG kinetic imaging during the initial leakage phase was diagnostic for quantitative vascular permeability within pancreatic tumors. Methods for autogain correction and normalized model-based interpretation allowed for quantification of extraction fraction and difference identification between tumor types in early timepoints. |
format | Online Article Text |
id | pubmed-10344470 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Society of Photo-Optical Instrumentation Engineers |
record_format | MEDLINE/PubMed |
spelling | pubmed-103444702023-07-14 Mapping estimates of vascular permeability with a clinical indocyanine green fluorescence imaging system in experimental pancreatic adenocarcinoma tumors Reed, Matthew S. Ochoa, Marien Tichauer, Kenneth M. Weichmann, Ashley Doyley, Marvin M. Pogue, Brian W. J Biomed Opt Imaging SIGNIFICANCE: Pancreatic cancer tumors are known to be avascular, but their neovascular capillaries are still chaotic leaky vessels. Capillary permeability could have significant value for therapy assessment, and its quantification might be possible with macroscopic imaging of indocyanine green (ICG) kinetics in tissue. AIM: The capacity of using standard fluorescence surgical systems for ICG kinetic imaging as a probe for capillary leakage was evaluated using a clinical surgical fluorescence imaging system, as interpreted through vascular permeability modeling. APPROACH: Xenograft pancreatic adenocarcinoma models were imaged in mice during bolus injection of ICG to capture the kinetics of uptake. Image analysis included ratiometric data, normalization, and match to theoretical modeling. Kinetic data were converted into the extraction fraction of the capillary leakage. RESULTS: Pancreatic tumors were usually less fluorescent than the surrounding healthy tissues, but still the rate of tumor perfusion could be assessed to quantify capillary extraction. Model simulations showed that flow kinetics stabilized after about 1 min beyond the initial bolus injection and that the relative extraction fraction model estimates matched the experimental data of normalized uptake within the tissue. The kinetics in the time period of 1 to 2 min post-injection provided optimal differential data between AsPC1 and BxPC3 tumors, although high individual variation exists between tumors. CONCLUSIONS: ICG kinetic imaging during the initial leakage phase was diagnostic for quantitative vascular permeability within pancreatic tumors. Methods for autogain correction and normalized model-based interpretation allowed for quantification of extraction fraction and difference identification between tumor types in early timepoints. Society of Photo-Optical Instrumentation Engineers 2023-07-13 2023-07 /pmc/articles/PMC10344470/ /pubmed/37457627 http://dx.doi.org/10.1117/1.JBO.28.7.076001 Text en © 2023 The Authors https://creativecommons.org/licenses/by/4.0/Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. |
spellingShingle | Imaging Reed, Matthew S. Ochoa, Marien Tichauer, Kenneth M. Weichmann, Ashley Doyley, Marvin M. Pogue, Brian W. Mapping estimates of vascular permeability with a clinical indocyanine green fluorescence imaging system in experimental pancreatic adenocarcinoma tumors |
title | Mapping estimates of vascular permeability with a clinical indocyanine green fluorescence imaging system in experimental pancreatic adenocarcinoma tumors |
title_full | Mapping estimates of vascular permeability with a clinical indocyanine green fluorescence imaging system in experimental pancreatic adenocarcinoma tumors |
title_fullStr | Mapping estimates of vascular permeability with a clinical indocyanine green fluorescence imaging system in experimental pancreatic adenocarcinoma tumors |
title_full_unstemmed | Mapping estimates of vascular permeability with a clinical indocyanine green fluorescence imaging system in experimental pancreatic adenocarcinoma tumors |
title_short | Mapping estimates of vascular permeability with a clinical indocyanine green fluorescence imaging system in experimental pancreatic adenocarcinoma tumors |
title_sort | mapping estimates of vascular permeability with a clinical indocyanine green fluorescence imaging system in experimental pancreatic adenocarcinoma tumors |
topic | Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10344470/ https://www.ncbi.nlm.nih.gov/pubmed/37457627 http://dx.doi.org/10.1117/1.JBO.28.7.076001 |
work_keys_str_mv | AT reedmatthews mappingestimatesofvascularpermeabilitywithaclinicalindocyaninegreenfluorescenceimagingsysteminexperimentalpancreaticadenocarcinomatumors AT ochoamarien mappingestimatesofvascularpermeabilitywithaclinicalindocyaninegreenfluorescenceimagingsysteminexperimentalpancreaticadenocarcinomatumors AT tichauerkennethm mappingestimatesofvascularpermeabilitywithaclinicalindocyaninegreenfluorescenceimagingsysteminexperimentalpancreaticadenocarcinomatumors AT weichmannashley mappingestimatesofvascularpermeabilitywithaclinicalindocyaninegreenfluorescenceimagingsysteminexperimentalpancreaticadenocarcinomatumors AT doyleymarvinm mappingestimatesofvascularpermeabilitywithaclinicalindocyaninegreenfluorescenceimagingsysteminexperimentalpancreaticadenocarcinomatumors AT poguebrianw mappingestimatesofvascularpermeabilitywithaclinicalindocyaninegreenfluorescenceimagingsysteminexperimentalpancreaticadenocarcinomatumors |