Cargando…

Impact of titanium-coated polypropylene mesh on functional outcome and quality of life after inguinal hernia repair

OBJECTIVE: This study aims to compare the clinical outcomes of complications, quality of life, and chronic pain between titanium-coated polypropylene mesh and polypropylene mesh after Lichtenstein or TAPP surgery. METHODS: A retrospective cohort study was conducted, involving patients who underwent...

Descripción completa

Detalles Bibliográficos
Autores principales: Xiao, Yelei, Zuo, Xiangyi, Li, Huanhuan, Zhao, Yu, Wang, Xuehu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10345250/
https://www.ncbi.nlm.nih.gov/pubmed/37455954
http://dx.doi.org/10.1016/j.heliyon.2023.e17691
_version_ 1785073044341915648
author Xiao, Yelei
Zuo, Xiangyi
Li, Huanhuan
Zhao, Yu
Wang, Xuehu
author_facet Xiao, Yelei
Zuo, Xiangyi
Li, Huanhuan
Zhao, Yu
Wang, Xuehu
author_sort Xiao, Yelei
collection PubMed
description OBJECTIVE: This study aims to compare the clinical outcomes of complications, quality of life, and chronic pain between titanium-coated polypropylene mesh and polypropylene mesh after Lichtenstein or TAPP surgery. METHODS: A retrospective cohort study was conducted, involving patients who underwent inguinal hernia repair using Timesh light®, Optilene LP®, or 3DMax™ meshes between January 2020 and May 2022. Based on the surgical method, patients were divided into Lichtenstein and TAPP groups, and further categorized according to the type of mesh used. The primary endpoints assessed postoperative complications, postoperative pain, and postoperative quality of life. Secondary endpoints included postoperative sensation in the surgical area and postoperative recurrence rate. RESULTS: A total of 180 Lichtenstein procedures and 478 TAPP procedures were included in the analysis after propensity score matching. The findings revealed that patients with titanium-coated polypropylene mesh did not exhibit significant advantages in perioperative data. Within three months to one year after TAPP surgery, patients with the titanium-coated polypropylene mesh reported improved foreign body sensation during activities (P = 0.002) and a lower incidence of chronic pain (P = 0.008). However, after one year, these advantages of titanium-coated polypropylene mesh were no longer significant during activity or at rest. In the TAPP group, the titanium-coated polypropylene mesh depicted advantages in the single score of the SF-36 questionnaire. CONCLUSIONS: The utilization of titanium-coated polypropylene mesh resulted in reduced foreign body sensation and chronic pain in activity within one year after TAPP surgery, significantly enhancing certain aspects of the patient's quality of life compared to polypropylene mesh.
format Online
Article
Text
id pubmed-10345250
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-103452502023-07-15 Impact of titanium-coated polypropylene mesh on functional outcome and quality of life after inguinal hernia repair Xiao, Yelei Zuo, Xiangyi Li, Huanhuan Zhao, Yu Wang, Xuehu Heliyon Research Article OBJECTIVE: This study aims to compare the clinical outcomes of complications, quality of life, and chronic pain between titanium-coated polypropylene mesh and polypropylene mesh after Lichtenstein or TAPP surgery. METHODS: A retrospective cohort study was conducted, involving patients who underwent inguinal hernia repair using Timesh light®, Optilene LP®, or 3DMax™ meshes between January 2020 and May 2022. Based on the surgical method, patients were divided into Lichtenstein and TAPP groups, and further categorized according to the type of mesh used. The primary endpoints assessed postoperative complications, postoperative pain, and postoperative quality of life. Secondary endpoints included postoperative sensation in the surgical area and postoperative recurrence rate. RESULTS: A total of 180 Lichtenstein procedures and 478 TAPP procedures were included in the analysis after propensity score matching. The findings revealed that patients with titanium-coated polypropylene mesh did not exhibit significant advantages in perioperative data. Within three months to one year after TAPP surgery, patients with the titanium-coated polypropylene mesh reported improved foreign body sensation during activities (P = 0.002) and a lower incidence of chronic pain (P = 0.008). However, after one year, these advantages of titanium-coated polypropylene mesh were no longer significant during activity or at rest. In the TAPP group, the titanium-coated polypropylene mesh depicted advantages in the single score of the SF-36 questionnaire. CONCLUSIONS: The utilization of titanium-coated polypropylene mesh resulted in reduced foreign body sensation and chronic pain in activity within one year after TAPP surgery, significantly enhancing certain aspects of the patient's quality of life compared to polypropylene mesh. Elsevier 2023-06-29 /pmc/articles/PMC10345250/ /pubmed/37455954 http://dx.doi.org/10.1016/j.heliyon.2023.e17691 Text en © 2023 Published by Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Xiao, Yelei
Zuo, Xiangyi
Li, Huanhuan
Zhao, Yu
Wang, Xuehu
Impact of titanium-coated polypropylene mesh on functional outcome and quality of life after inguinal hernia repair
title Impact of titanium-coated polypropylene mesh on functional outcome and quality of life after inguinal hernia repair
title_full Impact of titanium-coated polypropylene mesh on functional outcome and quality of life after inguinal hernia repair
title_fullStr Impact of titanium-coated polypropylene mesh on functional outcome and quality of life after inguinal hernia repair
title_full_unstemmed Impact of titanium-coated polypropylene mesh on functional outcome and quality of life after inguinal hernia repair
title_short Impact of titanium-coated polypropylene mesh on functional outcome and quality of life after inguinal hernia repair
title_sort impact of titanium-coated polypropylene mesh on functional outcome and quality of life after inguinal hernia repair
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10345250/
https://www.ncbi.nlm.nih.gov/pubmed/37455954
http://dx.doi.org/10.1016/j.heliyon.2023.e17691
work_keys_str_mv AT xiaoyelei impactoftitaniumcoatedpolypropylenemeshonfunctionaloutcomeandqualityoflifeafteringuinalherniarepair
AT zuoxiangyi impactoftitaniumcoatedpolypropylenemeshonfunctionaloutcomeandqualityoflifeafteringuinalherniarepair
AT lihuanhuan impactoftitaniumcoatedpolypropylenemeshonfunctionaloutcomeandqualityoflifeafteringuinalherniarepair
AT zhaoyu impactoftitaniumcoatedpolypropylenemeshonfunctionaloutcomeandqualityoflifeafteringuinalherniarepair
AT wangxuehu impactoftitaniumcoatedpolypropylenemeshonfunctionaloutcomeandqualityoflifeafteringuinalherniarepair