Cargando…

Enhancement of Refractive Index Sensitivity Using Small Footprint S-Shaped Double-Spiral Resonators for Biosensing

We demonstrate an S-shaped double-spiral microresonator (DSR) for detecting small volumes of analytes, such as liquids or gases, penetrating a microfluidic channel. Optical-ring resonators have been applied as label-free and high-sensitivity biosensors by using an evanescent field for sensing the re...

Descripción completa

Detalles Bibliográficos
Autores principales: Igarashi, Anh, Abe, Maho, Kuroiwa, Shigeki, Ohashi, Keishi, Yamada, Hirohito
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10346211/
https://www.ncbi.nlm.nih.gov/pubmed/37448026
http://dx.doi.org/10.3390/s23136177
_version_ 1785073260716621824
author Igarashi, Anh
Abe, Maho
Kuroiwa, Shigeki
Ohashi, Keishi
Yamada, Hirohito
author_facet Igarashi, Anh
Abe, Maho
Kuroiwa, Shigeki
Ohashi, Keishi
Yamada, Hirohito
author_sort Igarashi, Anh
collection PubMed
description We demonstrate an S-shaped double-spiral microresonator (DSR) for detecting small volumes of analytes, such as liquids or gases, penetrating a microfluidic channel. Optical-ring resonators have been applied as label-free and high-sensitivity biosensors by using an evanescent field for sensing the refractive index of analytes. Enlarging the ring resonator size is a solution for amplifying the interactions between the evanescent field and biomolecules to obtain a higher refractive index sensitivity of the attached analytes. However, it requires a large platform of a hundred square millimeters, and 99% of the cavity area would not involve evanescent field sensing. In this report, we demonstrate the novel design of a Si-based S-shaped double-spiral resonator on a silicon-on-insulator substrate for which the cavity size was 41.6 µm × 88.4 µm. The proposed resonator footprint was reduced by 680 times compared to a microring resonator with the same cavity area. The fabricated resonator exposed more sensitive optical characteristics for refractive index biosensing thanks to the enhanced contact interface by a long cavity length of DSR structures. High quality factors of 1.8 × 10(4) were demonstrated for 1.2 mm length DSR structures, which were more than two times higher than the quality factors of microring resonators. A bulk sensitivity of 1410 nm/RIU was calculated for detecting 1 µL IPA solutions inside a 200 µm wide microchannel by using the DSR cavity, which had more than a 10-fold higher sensitivity than the sensitivity of the microring resonators. A DSR device was also used for the detection of 100 ppm acetone gas inside a closed bottle.
format Online
Article
Text
id pubmed-10346211
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103462112023-07-15 Enhancement of Refractive Index Sensitivity Using Small Footprint S-Shaped Double-Spiral Resonators for Biosensing Igarashi, Anh Abe, Maho Kuroiwa, Shigeki Ohashi, Keishi Yamada, Hirohito Sensors (Basel) Article We demonstrate an S-shaped double-spiral microresonator (DSR) for detecting small volumes of analytes, such as liquids or gases, penetrating a microfluidic channel. Optical-ring resonators have been applied as label-free and high-sensitivity biosensors by using an evanescent field for sensing the refractive index of analytes. Enlarging the ring resonator size is a solution for amplifying the interactions between the evanescent field and biomolecules to obtain a higher refractive index sensitivity of the attached analytes. However, it requires a large platform of a hundred square millimeters, and 99% of the cavity area would not involve evanescent field sensing. In this report, we demonstrate the novel design of a Si-based S-shaped double-spiral resonator on a silicon-on-insulator substrate for which the cavity size was 41.6 µm × 88.4 µm. The proposed resonator footprint was reduced by 680 times compared to a microring resonator with the same cavity area. The fabricated resonator exposed more sensitive optical characteristics for refractive index biosensing thanks to the enhanced contact interface by a long cavity length of DSR structures. High quality factors of 1.8 × 10(4) were demonstrated for 1.2 mm length DSR structures, which were more than two times higher than the quality factors of microring resonators. A bulk sensitivity of 1410 nm/RIU was calculated for detecting 1 µL IPA solutions inside a 200 µm wide microchannel by using the DSR cavity, which had more than a 10-fold higher sensitivity than the sensitivity of the microring resonators. A DSR device was also used for the detection of 100 ppm acetone gas inside a closed bottle. MDPI 2023-07-05 /pmc/articles/PMC10346211/ /pubmed/37448026 http://dx.doi.org/10.3390/s23136177 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Igarashi, Anh
Abe, Maho
Kuroiwa, Shigeki
Ohashi, Keishi
Yamada, Hirohito
Enhancement of Refractive Index Sensitivity Using Small Footprint S-Shaped Double-Spiral Resonators for Biosensing
title Enhancement of Refractive Index Sensitivity Using Small Footprint S-Shaped Double-Spiral Resonators for Biosensing
title_full Enhancement of Refractive Index Sensitivity Using Small Footprint S-Shaped Double-Spiral Resonators for Biosensing
title_fullStr Enhancement of Refractive Index Sensitivity Using Small Footprint S-Shaped Double-Spiral Resonators for Biosensing
title_full_unstemmed Enhancement of Refractive Index Sensitivity Using Small Footprint S-Shaped Double-Spiral Resonators for Biosensing
title_short Enhancement of Refractive Index Sensitivity Using Small Footprint S-Shaped Double-Spiral Resonators for Biosensing
title_sort enhancement of refractive index sensitivity using small footprint s-shaped double-spiral resonators for biosensing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10346211/
https://www.ncbi.nlm.nih.gov/pubmed/37448026
http://dx.doi.org/10.3390/s23136177
work_keys_str_mv AT igarashianh enhancementofrefractiveindexsensitivityusingsmallfootprintsshapeddoublespiralresonatorsforbiosensing
AT abemaho enhancementofrefractiveindexsensitivityusingsmallfootprintsshapeddoublespiralresonatorsforbiosensing
AT kuroiwashigeki enhancementofrefractiveindexsensitivityusingsmallfootprintsshapeddoublespiralresonatorsforbiosensing
AT ohashikeishi enhancementofrefractiveindexsensitivityusingsmallfootprintsshapeddoublespiralresonatorsforbiosensing
AT yamadahirohito enhancementofrefractiveindexsensitivityusingsmallfootprintsshapeddoublespiralresonatorsforbiosensing