Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test
In recent years, there has been an exponential increase in the number of devices developed to measure or estimate physical exercise. However, before these devices can be used in a practical and research environment, it is necessary to determine their validity and reliability. The purpose of this stu...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10346244/ https://www.ncbi.nlm.nih.gov/pubmed/37447682 http://dx.doi.org/10.3390/s23135832 |
_version_ | 1785073269082161152 |
---|---|
author | Montoro-Bombú, Raynier Gomes, Beatriz Branquinho Santos, Amândio Rama, Luis |
author_facet | Montoro-Bombú, Raynier Gomes, Beatriz Branquinho Santos, Amândio Rama, Luis |
author_sort | Montoro-Bombú, Raynier |
collection | PubMed |
description | In recent years, there has been an exponential increase in the number of devices developed to measure or estimate physical exercise. However, before these devices can be used in a practical and research environment, it is necessary to determine their validity and reliability. The purpose of this study is to test the validity and reliability of a load cell sensor-based device (LC) for measuring the peak force (PFr) and the rate of force development (RFD) during the isometric mid-thigh pull (IMTP) test, using a force plate (FP) as the gold standard. Forty-two undergraduate sport science students (male and female) participated in this study. In a single session, they performed three repetitions of the IMTP test, being tested simultaneously with an LC device and a Kistler force platform (FP). The PFr and RFD data were obtained from the force-time curve of the FP and compared with the LC data, provided automatically by the software of the device (Smart Traction device©). The mean difference between the results obtained by the LC device and the gold-standard equipment (FP) was not significantly different (p > 0.05), for both PFr and RFD, which suggests the validity of the ST results. Bland–Altman analysis showed a small mean difference in PFr = 1.69 N, upper bound = 47.88 N, and lower bound = −51.27 N. RFD showed that the mean difference was −5.27 N/s, upper limit = 44.36 N/s, and lower limit = −54.91 N/s. Our results suggest that the LC device can be used in the assessment of the isometric-mid-thigh-pull test as a valid and reliable tool. It is recommended that this device’s users consider these research results before putting the ST into clinical practice. |
format | Online Article Text |
id | pubmed-10346244 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103462442023-07-15 Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test Montoro-Bombú, Raynier Gomes, Beatriz Branquinho Santos, Amândio Rama, Luis Sensors (Basel) Communication In recent years, there has been an exponential increase in the number of devices developed to measure or estimate physical exercise. However, before these devices can be used in a practical and research environment, it is necessary to determine their validity and reliability. The purpose of this study is to test the validity and reliability of a load cell sensor-based device (LC) for measuring the peak force (PFr) and the rate of force development (RFD) during the isometric mid-thigh pull (IMTP) test, using a force plate (FP) as the gold standard. Forty-two undergraduate sport science students (male and female) participated in this study. In a single session, they performed three repetitions of the IMTP test, being tested simultaneously with an LC device and a Kistler force platform (FP). The PFr and RFD data were obtained from the force-time curve of the FP and compared with the LC data, provided automatically by the software of the device (Smart Traction device©). The mean difference between the results obtained by the LC device and the gold-standard equipment (FP) was not significantly different (p > 0.05), for both PFr and RFD, which suggests the validity of the ST results. Bland–Altman analysis showed a small mean difference in PFr = 1.69 N, upper bound = 47.88 N, and lower bound = −51.27 N. RFD showed that the mean difference was −5.27 N/s, upper limit = 44.36 N/s, and lower limit = −54.91 N/s. Our results suggest that the LC device can be used in the assessment of the isometric-mid-thigh-pull test as a valid and reliable tool. It is recommended that this device’s users consider these research results before putting the ST into clinical practice. MDPI 2023-06-22 /pmc/articles/PMC10346244/ /pubmed/37447682 http://dx.doi.org/10.3390/s23135832 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Communication Montoro-Bombú, Raynier Gomes, Beatriz Branquinho Santos, Amândio Rama, Luis Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test |
title | Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test |
title_full | Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test |
title_fullStr | Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test |
title_full_unstemmed | Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test |
title_short | Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test |
title_sort | validity and reliability of a load cell sensor-based device for assessment of the isometric mid-thigh pull test |
topic | Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10346244/ https://www.ncbi.nlm.nih.gov/pubmed/37447682 http://dx.doi.org/10.3390/s23135832 |
work_keys_str_mv | AT montorobomburaynier validityandreliabilityofaloadcellsensorbaseddeviceforassessmentoftheisometricmidthighpulltest AT gomesbeatrizbranquinho validityandreliabilityofaloadcellsensorbaseddeviceforassessmentoftheisometricmidthighpulltest AT santosamandio validityandreliabilityofaloadcellsensorbaseddeviceforassessmentoftheisometricmidthighpulltest AT ramaluis validityandreliabilityofaloadcellsensorbaseddeviceforassessmentoftheisometricmidthighpulltest |