Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test

In recent years, there has been an exponential increase in the number of devices developed to measure or estimate physical exercise. However, before these devices can be used in a practical and research environment, it is necessary to determine their validity and reliability. The purpose of this stu...

Descripción completa

Detalles Bibliográficos
Autores principales: Montoro-Bombú, Raynier, Gomes, Beatriz Branquinho, Santos, Amândio, Rama, Luis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10346244/
https://www.ncbi.nlm.nih.gov/pubmed/37447682
http://dx.doi.org/10.3390/s23135832
_version_ 1785073269082161152
author Montoro-Bombú, Raynier
Gomes, Beatriz Branquinho
Santos, Amândio
Rama, Luis
author_facet Montoro-Bombú, Raynier
Gomes, Beatriz Branquinho
Santos, Amândio
Rama, Luis
author_sort Montoro-Bombú, Raynier
collection PubMed
description In recent years, there has been an exponential increase in the number of devices developed to measure or estimate physical exercise. However, before these devices can be used in a practical and research environment, it is necessary to determine their validity and reliability. The purpose of this study is to test the validity and reliability of a load cell sensor-based device (LC) for measuring the peak force (PFr) and the rate of force development (RFD) during the isometric mid-thigh pull (IMTP) test, using a force plate (FP) as the gold standard. Forty-two undergraduate sport science students (male and female) participated in this study. In a single session, they performed three repetitions of the IMTP test, being tested simultaneously with an LC device and a Kistler force platform (FP). The PFr and RFD data were obtained from the force-time curve of the FP and compared with the LC data, provided automatically by the software of the device (Smart Traction device©). The mean difference between the results obtained by the LC device and the gold-standard equipment (FP) was not significantly different (p > 0.05), for both PFr and RFD, which suggests the validity of the ST results. Bland–Altman analysis showed a small mean difference in PFr = 1.69 N, upper bound = 47.88 N, and lower bound = −51.27 N. RFD showed that the mean difference was −5.27 N/s, upper limit = 44.36 N/s, and lower limit = −54.91 N/s. Our results suggest that the LC device can be used in the assessment of the isometric-mid-thigh-pull test as a valid and reliable tool. It is recommended that this device’s users consider these research results before putting the ST into clinical practice.
format Online
Article
Text
id pubmed-10346244
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103462442023-07-15 Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test Montoro-Bombú, Raynier Gomes, Beatriz Branquinho Santos, Amândio Rama, Luis Sensors (Basel) Communication In recent years, there has been an exponential increase in the number of devices developed to measure or estimate physical exercise. However, before these devices can be used in a practical and research environment, it is necessary to determine their validity and reliability. The purpose of this study is to test the validity and reliability of a load cell sensor-based device (LC) for measuring the peak force (PFr) and the rate of force development (RFD) during the isometric mid-thigh pull (IMTP) test, using a force plate (FP) as the gold standard. Forty-two undergraduate sport science students (male and female) participated in this study. In a single session, they performed three repetitions of the IMTP test, being tested simultaneously with an LC device and a Kistler force platform (FP). The PFr and RFD data were obtained from the force-time curve of the FP and compared with the LC data, provided automatically by the software of the device (Smart Traction device©). The mean difference between the results obtained by the LC device and the gold-standard equipment (FP) was not significantly different (p > 0.05), for both PFr and RFD, which suggests the validity of the ST results. Bland–Altman analysis showed a small mean difference in PFr = 1.69 N, upper bound = 47.88 N, and lower bound = −51.27 N. RFD showed that the mean difference was −5.27 N/s, upper limit = 44.36 N/s, and lower limit = −54.91 N/s. Our results suggest that the LC device can be used in the assessment of the isometric-mid-thigh-pull test as a valid and reliable tool. It is recommended that this device’s users consider these research results before putting the ST into clinical practice. MDPI 2023-06-22 /pmc/articles/PMC10346244/ /pubmed/37447682 http://dx.doi.org/10.3390/s23135832 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Montoro-Bombú, Raynier
Gomes, Beatriz Branquinho
Santos, Amândio
Rama, Luis
Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test
title Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test
title_full Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test
title_fullStr Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test
title_full_unstemmed Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test
title_short Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test
title_sort validity and reliability of a load cell sensor-based device for assessment of the isometric mid-thigh pull test
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10346244/
https://www.ncbi.nlm.nih.gov/pubmed/37447682
http://dx.doi.org/10.3390/s23135832
work_keys_str_mv AT montorobomburaynier validityandreliabilityofaloadcellsensorbaseddeviceforassessmentoftheisometricmidthighpulltest
AT gomesbeatrizbranquinho validityandreliabilityofaloadcellsensorbaseddeviceforassessmentoftheisometricmidthighpulltest
AT santosamandio validityandreliabilityofaloadcellsensorbaseddeviceforassessmentoftheisometricmidthighpulltest
AT ramaluis validityandreliabilityofaloadcellsensorbaseddeviceforassessmentoftheisometricmidthighpulltest