Uncertainty of Standardized Track Insulation Measurement Methods for Stray Current Assessment

Stray current is a relevant phenomenon in particular for DC electrified transportation systems, affecting track and infrastructure within the right of way and other structures and installations nearby. It worsens with time and the level of protection depends on timely maintenance, as well as correct...

Descripción completa

Detalles Bibliográficos
Autores principales: Bhagat, Sahil, Bongiorno, Jacopo, Mariscotti, Andrea
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10346591/
https://www.ncbi.nlm.nih.gov/pubmed/37447751
http://dx.doi.org/10.3390/s23135900
_version_ 1785073348952195072
author Bhagat, Sahil
Bongiorno, Jacopo
Mariscotti, Andrea
author_facet Bhagat, Sahil
Bongiorno, Jacopo
Mariscotti, Andrea
author_sort Bhagat, Sahil
collection PubMed
description Stray current is a relevant phenomenon in particular for DC electrified transportation systems, affecting track and infrastructure within the right of way and other structures and installations nearby. It worsens with time and the level of protection depends on timely maintenance, as well as correct design choices. The assessment of track insulation is the starting point for both stray current monitoring systems and at commissioning or upon major changes. Standardized methods (ref. EN 50122-2 or IEC 62128-2) have been almost unchanged in the last 20 years but suffer from accuracy issues and variability due to parameters and conditions not under the operator’s control. The uncertainty of test methods is increasingly important now that contractual specifications require a high level of insulation for new systems. A critical discussion and analysis of the sources of variability and practical constraints is proposed, followed by an evaluation of uncertainty, with the objective not only to assess the accuracy of the provided results, but also to foster research on innovative, more flexible and accurate methods.
format Online
Article
Text
id pubmed-10346591
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103465912023-07-15 Uncertainty of Standardized Track Insulation Measurement Methods for Stray Current Assessment Bhagat, Sahil Bongiorno, Jacopo Mariscotti, Andrea Sensors (Basel) Article Stray current is a relevant phenomenon in particular for DC electrified transportation systems, affecting track and infrastructure within the right of way and other structures and installations nearby. It worsens with time and the level of protection depends on timely maintenance, as well as correct design choices. The assessment of track insulation is the starting point for both stray current monitoring systems and at commissioning or upon major changes. Standardized methods (ref. EN 50122-2 or IEC 62128-2) have been almost unchanged in the last 20 years but suffer from accuracy issues and variability due to parameters and conditions not under the operator’s control. The uncertainty of test methods is increasingly important now that contractual specifications require a high level of insulation for new systems. A critical discussion and analysis of the sources of variability and practical constraints is proposed, followed by an evaluation of uncertainty, with the objective not only to assess the accuracy of the provided results, but also to foster research on innovative, more flexible and accurate methods. MDPI 2023-06-25 /pmc/articles/PMC10346591/ /pubmed/37447751 http://dx.doi.org/10.3390/s23135900 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bhagat, Sahil
Bongiorno, Jacopo
Mariscotti, Andrea
Uncertainty of Standardized Track Insulation Measurement Methods for Stray Current Assessment
title Uncertainty of Standardized Track Insulation Measurement Methods for Stray Current Assessment
title_full Uncertainty of Standardized Track Insulation Measurement Methods for Stray Current Assessment
title_fullStr Uncertainty of Standardized Track Insulation Measurement Methods for Stray Current Assessment
title_full_unstemmed Uncertainty of Standardized Track Insulation Measurement Methods for Stray Current Assessment
title_short Uncertainty of Standardized Track Insulation Measurement Methods for Stray Current Assessment
title_sort uncertainty of standardized track insulation measurement methods for stray current assessment
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10346591/
https://www.ncbi.nlm.nih.gov/pubmed/37447751
http://dx.doi.org/10.3390/s23135900
work_keys_str_mv AT bhagatsahil uncertaintyofstandardizedtrackinsulationmeasurementmethodsforstraycurrentassessment
AT bongiornojacopo uncertaintyofstandardizedtrackinsulationmeasurementmethodsforstraycurrentassessment
AT mariscottiandrea uncertaintyofstandardizedtrackinsulationmeasurementmethodsforstraycurrentassessment