Cargando…
Signal Quality Analysis of Single-Arm Electrocardiography
The number of people experiencing mental stress or emotional dysfunction has increased since the onset of the COVID-19 pandemic, as many individuals have had to adapt their daily lives. Numerous studies have demonstrated that mental health disorders can pose a risk for certain diseases, and they are...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10346735/ https://www.ncbi.nlm.nih.gov/pubmed/37447668 http://dx.doi.org/10.3390/s23135818 |
_version_ | 1785073383540523008 |
---|---|
author | Wang, Jia-Jung Liu, Shing-Hong Tsai, Cheng-Hsien Manousakas, Ioannis Zhu, Xin Lee, Thung-Lip |
author_facet | Wang, Jia-Jung Liu, Shing-Hong Tsai, Cheng-Hsien Manousakas, Ioannis Zhu, Xin Lee, Thung-Lip |
author_sort | Wang, Jia-Jung |
collection | PubMed |
description | The number of people experiencing mental stress or emotional dysfunction has increased since the onset of the COVID-19 pandemic, as many individuals have had to adapt their daily lives. Numerous studies have demonstrated that mental health disorders can pose a risk for certain diseases, and they are also closely associated with the problem of mental workload. Now, wearable devices and mobile health applications are being utilized to monitor and assess individuals’ mental health conditions on a daily basis using heart rate variability (HRV), typically measured by the R-to-R wave interval (RRI) of an electrocardiogram (ECG). However, portable or wearable ECG devices generally require two electrodes to perform bipolar limb leads, such as the Einthoven triangle. This study aims to develop a single-arm ECG measurement method, with lead I ECG serving as the gold standard. We conducted static and dynamic experiments to analyze the morphological performance and signal-to-noise ratio (SNR) of the single-arm ECG. Three morphological features were defined, RRI, the duration of the QRS complex wave, and the amplitude of the R wave. Thirty subjects participated in this study. The results indicated that RRI exhibited the highest cross-correlation (R = 0.9942) between the single-arm ECG and lead I ECG, while the duration of the QRS complex wave showed the weakest cross-correlation (R = 0.2201). The best SNR obtained was 26.1 ± 5.9 dB during the resting experiment, whereas the worst SNR was 12.5 ± 5.1 dB during the raising and lowering of the arm along the z-axis. This single-arm ECG measurement method offers easier operation compared to traditional ECG measurement techniques, making it applicable for HRV measurement and the detection of an irregular RRI. |
format | Online Article Text |
id | pubmed-10346735 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103467352023-07-15 Signal Quality Analysis of Single-Arm Electrocardiography Wang, Jia-Jung Liu, Shing-Hong Tsai, Cheng-Hsien Manousakas, Ioannis Zhu, Xin Lee, Thung-Lip Sensors (Basel) Article The number of people experiencing mental stress or emotional dysfunction has increased since the onset of the COVID-19 pandemic, as many individuals have had to adapt their daily lives. Numerous studies have demonstrated that mental health disorders can pose a risk for certain diseases, and they are also closely associated with the problem of mental workload. Now, wearable devices and mobile health applications are being utilized to monitor and assess individuals’ mental health conditions on a daily basis using heart rate variability (HRV), typically measured by the R-to-R wave interval (RRI) of an electrocardiogram (ECG). However, portable or wearable ECG devices generally require two electrodes to perform bipolar limb leads, such as the Einthoven triangle. This study aims to develop a single-arm ECG measurement method, with lead I ECG serving as the gold standard. We conducted static and dynamic experiments to analyze the morphological performance and signal-to-noise ratio (SNR) of the single-arm ECG. Three morphological features were defined, RRI, the duration of the QRS complex wave, and the amplitude of the R wave. Thirty subjects participated in this study. The results indicated that RRI exhibited the highest cross-correlation (R = 0.9942) between the single-arm ECG and lead I ECG, while the duration of the QRS complex wave showed the weakest cross-correlation (R = 0.2201). The best SNR obtained was 26.1 ± 5.9 dB during the resting experiment, whereas the worst SNR was 12.5 ± 5.1 dB during the raising and lowering of the arm along the z-axis. This single-arm ECG measurement method offers easier operation compared to traditional ECG measurement techniques, making it applicable for HRV measurement and the detection of an irregular RRI. MDPI 2023-06-22 /pmc/articles/PMC10346735/ /pubmed/37447668 http://dx.doi.org/10.3390/s23135818 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wang, Jia-Jung Liu, Shing-Hong Tsai, Cheng-Hsien Manousakas, Ioannis Zhu, Xin Lee, Thung-Lip Signal Quality Analysis of Single-Arm Electrocardiography |
title | Signal Quality Analysis of Single-Arm Electrocardiography |
title_full | Signal Quality Analysis of Single-Arm Electrocardiography |
title_fullStr | Signal Quality Analysis of Single-Arm Electrocardiography |
title_full_unstemmed | Signal Quality Analysis of Single-Arm Electrocardiography |
title_short | Signal Quality Analysis of Single-Arm Electrocardiography |
title_sort | signal quality analysis of single-arm electrocardiography |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10346735/ https://www.ncbi.nlm.nih.gov/pubmed/37447668 http://dx.doi.org/10.3390/s23135818 |
work_keys_str_mv | AT wangjiajung signalqualityanalysisofsinglearmelectrocardiography AT liushinghong signalqualityanalysisofsinglearmelectrocardiography AT tsaichenghsien signalqualityanalysisofsinglearmelectrocardiography AT manousakasioannis signalqualityanalysisofsinglearmelectrocardiography AT zhuxin signalqualityanalysisofsinglearmelectrocardiography AT leethunglip signalqualityanalysisofsinglearmelectrocardiography |