Cargando…

Measurement of Pneumatic Valve Flow Parameters on the Test Bench with Interchangeable Venturi Tubes and Their Practical Use

A test bench with interchangeable venturi tubes was built to automatically measure the flow parameters of pneumatic valves of a wide range of sizes. This measuring stand contained components recommended by the ISO 6358 standard, an individually configured flow meter circuit, and HMI measurement and...

Descripción completa

Detalles Bibliográficos
Autor principal: Dindorf, Ryszard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10346742/
https://www.ncbi.nlm.nih.gov/pubmed/37447891
http://dx.doi.org/10.3390/s23136042
_version_ 1785073385253896192
author Dindorf, Ryszard
author_facet Dindorf, Ryszard
author_sort Dindorf, Ryszard
collection PubMed
description A test bench with interchangeable venturi tubes was built to automatically measure the flow parameters of pneumatic valves of a wide range of sizes. This measuring stand contained components recommended by the ISO 6358 standard, an individually configured flow meter circuit, and HMI measurement and control panels. The flow meter circuit, individually configured with interchangeable venturi tubes, bypass loops, and Setaram thermal microflow meter, was calibrated using Molbloc/Molbox equipment. The tuning curve and theoretical flow rate characteristics of the tested valve were fitted to the flow rate measurement data. The best fit value of the critical pressure ratio was obtained using the numerical method of least squares minimization. The pneumatic valve with measured flow parameters was compared with data from the catalogue on the discharge characteristics of the compressed air tank. A practical solution for high-pressure tank discharge time using two valves connected in series to the hybrid tricycle bike (HTB) pneumatic propulsion system is presented. This article presents a solution to the practical problem of measuring the flow parameters of industrial pneumatic valves with a wide range of nominal diameters on a test bench with replaceable venturi tubes.
format Online
Article
Text
id pubmed-10346742
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103467422023-07-15 Measurement of Pneumatic Valve Flow Parameters on the Test Bench with Interchangeable Venturi Tubes and Their Practical Use Dindorf, Ryszard Sensors (Basel) Article A test bench with interchangeable venturi tubes was built to automatically measure the flow parameters of pneumatic valves of a wide range of sizes. This measuring stand contained components recommended by the ISO 6358 standard, an individually configured flow meter circuit, and HMI measurement and control panels. The flow meter circuit, individually configured with interchangeable venturi tubes, bypass loops, and Setaram thermal microflow meter, was calibrated using Molbloc/Molbox equipment. The tuning curve and theoretical flow rate characteristics of the tested valve were fitted to the flow rate measurement data. The best fit value of the critical pressure ratio was obtained using the numerical method of least squares minimization. The pneumatic valve with measured flow parameters was compared with data from the catalogue on the discharge characteristics of the compressed air tank. A practical solution for high-pressure tank discharge time using two valves connected in series to the hybrid tricycle bike (HTB) pneumatic propulsion system is presented. This article presents a solution to the practical problem of measuring the flow parameters of industrial pneumatic valves with a wide range of nominal diameters on a test bench with replaceable venturi tubes. MDPI 2023-06-29 /pmc/articles/PMC10346742/ /pubmed/37447891 http://dx.doi.org/10.3390/s23136042 Text en © 2023 by the author. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dindorf, Ryszard
Measurement of Pneumatic Valve Flow Parameters on the Test Bench with Interchangeable Venturi Tubes and Their Practical Use
title Measurement of Pneumatic Valve Flow Parameters on the Test Bench with Interchangeable Venturi Tubes and Their Practical Use
title_full Measurement of Pneumatic Valve Flow Parameters on the Test Bench with Interchangeable Venturi Tubes and Their Practical Use
title_fullStr Measurement of Pneumatic Valve Flow Parameters on the Test Bench with Interchangeable Venturi Tubes and Their Practical Use
title_full_unstemmed Measurement of Pneumatic Valve Flow Parameters on the Test Bench with Interchangeable Venturi Tubes and Their Practical Use
title_short Measurement of Pneumatic Valve Flow Parameters on the Test Bench with Interchangeable Venturi Tubes and Their Practical Use
title_sort measurement of pneumatic valve flow parameters on the test bench with interchangeable venturi tubes and their practical use
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10346742/
https://www.ncbi.nlm.nih.gov/pubmed/37447891
http://dx.doi.org/10.3390/s23136042
work_keys_str_mv AT dindorfryszard measurementofpneumaticvalveflowparametersonthetestbenchwithinterchangeableventuritubesandtheirpracticaluse