Thickness-Dependent Light Transmittance and Temperature Rise in Dual-Cure Bioactive and Light-Cure Bulk-Fill Composite Resins
This study aimed to assess the light transmittance (T) and temperature increase through different increments of dual-cure bioactive bulk-fill restorative material (ACTIVA), light-cure bulk-fill, and conventional composite resin materials. Cylindrical specimens with a diameter of 8 mm and heights of...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10347211/ https://www.ncbi.nlm.nih.gov/pubmed/37447483 http://dx.doi.org/10.3390/polym15132837 |
_version_ | 1785073496772050944 |
---|---|
author | Alharbi, Reema Alharbi, Eid Al-Haj Ali, Sanaa N. Farah, Ra’fat I. |
author_facet | Alharbi, Reema Alharbi, Eid Al-Haj Ali, Sanaa N. Farah, Ra’fat I. |
author_sort | Alharbi, Reema |
collection | PubMed |
description | This study aimed to assess the light transmittance (T) and temperature increase through different increments of dual-cure bioactive bulk-fill restorative material (ACTIVA), light-cure bulk-fill, and conventional composite resin materials. Cylindrical specimens with a diameter of 8 mm and heights of 1, 2, 3, and 4 mm of ACTIVA, Tetric-N-Ceram bulk-fill (TBF), Filtek One bulk-fill (FBF), and Filtek Z250 (FZ) (n = 6 per group, 96 in total) were light-cured with a visible blue low-intensity light-emitting diode (LED) (650–800 mW/cm(2) irradiance). T, and the temperature increase, were measured using an optical power meter and a digital thermometer during curing. The T mean values ranged between 0.012 and 0.239 (76.02 to 98.81% light attenuation), while the temperature rise mean values ranged between 9.02 and 20.80 °C. The parameters, including material type (partial eta squared (ηp(2)) = 0.284, p < 0.0001), thickness (ηp(2) = 0.284, p < 0.0001), and their interaction (ηp(2) = 0.185, p = 0.047), significantly affected the T values, whereas only the material type (ηp(2) = 0.352, p = 0.047) affected the temperature rise values. The T and temperature rise mean values were highest in ACTIVA increments of 1-mm increments, in particular, showing the highest T mean values, followed by similar increments of TBF. A significantly higher T was found in 1-mm increments compared to thicker increments for all materials (p < 0.0001), and a significant positive correlation existed between T and temperature rise values (r = 0.348, p = 0.001). These findings show that the bioactive material ACTIVA and TBF allow for better T than the other materials, with ACTIVA recording a higher temperature rise. However, the large light attenuation observed for all materials, irrespective of thickness, suggests that curing in more than one location with a low-intensity LED is necessary to optimize the curing process. Furthermore, incremental filling of bulk-fill materials using a low intensity LED could be beneficial. |
format | Online Article Text |
id | pubmed-10347211 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103472112023-07-15 Thickness-Dependent Light Transmittance and Temperature Rise in Dual-Cure Bioactive and Light-Cure Bulk-Fill Composite Resins Alharbi, Reema Alharbi, Eid Al-Haj Ali, Sanaa N. Farah, Ra’fat I. Polymers (Basel) Article This study aimed to assess the light transmittance (T) and temperature increase through different increments of dual-cure bioactive bulk-fill restorative material (ACTIVA), light-cure bulk-fill, and conventional composite resin materials. Cylindrical specimens with a diameter of 8 mm and heights of 1, 2, 3, and 4 mm of ACTIVA, Tetric-N-Ceram bulk-fill (TBF), Filtek One bulk-fill (FBF), and Filtek Z250 (FZ) (n = 6 per group, 96 in total) were light-cured with a visible blue low-intensity light-emitting diode (LED) (650–800 mW/cm(2) irradiance). T, and the temperature increase, were measured using an optical power meter and a digital thermometer during curing. The T mean values ranged between 0.012 and 0.239 (76.02 to 98.81% light attenuation), while the temperature rise mean values ranged between 9.02 and 20.80 °C. The parameters, including material type (partial eta squared (ηp(2)) = 0.284, p < 0.0001), thickness (ηp(2) = 0.284, p < 0.0001), and their interaction (ηp(2) = 0.185, p = 0.047), significantly affected the T values, whereas only the material type (ηp(2) = 0.352, p = 0.047) affected the temperature rise values. The T and temperature rise mean values were highest in ACTIVA increments of 1-mm increments, in particular, showing the highest T mean values, followed by similar increments of TBF. A significantly higher T was found in 1-mm increments compared to thicker increments for all materials (p < 0.0001), and a significant positive correlation existed between T and temperature rise values (r = 0.348, p = 0.001). These findings show that the bioactive material ACTIVA and TBF allow for better T than the other materials, with ACTIVA recording a higher temperature rise. However, the large light attenuation observed for all materials, irrespective of thickness, suggests that curing in more than one location with a low-intensity LED is necessary to optimize the curing process. Furthermore, incremental filling of bulk-fill materials using a low intensity LED could be beneficial. MDPI 2023-06-27 /pmc/articles/PMC10347211/ /pubmed/37447483 http://dx.doi.org/10.3390/polym15132837 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Alharbi, Reema Alharbi, Eid Al-Haj Ali, Sanaa N. Farah, Ra’fat I. Thickness-Dependent Light Transmittance and Temperature Rise in Dual-Cure Bioactive and Light-Cure Bulk-Fill Composite Resins |
title | Thickness-Dependent Light Transmittance and Temperature Rise in Dual-Cure Bioactive and Light-Cure Bulk-Fill Composite Resins |
title_full | Thickness-Dependent Light Transmittance and Temperature Rise in Dual-Cure Bioactive and Light-Cure Bulk-Fill Composite Resins |
title_fullStr | Thickness-Dependent Light Transmittance and Temperature Rise in Dual-Cure Bioactive and Light-Cure Bulk-Fill Composite Resins |
title_full_unstemmed | Thickness-Dependent Light Transmittance and Temperature Rise in Dual-Cure Bioactive and Light-Cure Bulk-Fill Composite Resins |
title_short | Thickness-Dependent Light Transmittance and Temperature Rise in Dual-Cure Bioactive and Light-Cure Bulk-Fill Composite Resins |
title_sort | thickness-dependent light transmittance and temperature rise in dual-cure bioactive and light-cure bulk-fill composite resins |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10347211/ https://www.ncbi.nlm.nih.gov/pubmed/37447483 http://dx.doi.org/10.3390/polym15132837 |
work_keys_str_mv | AT alharbireema thicknessdependentlighttransmittanceandtemperatureriseindualcurebioactiveandlightcurebulkfillcompositeresins AT alharbieid thicknessdependentlighttransmittanceandtemperatureriseindualcurebioactiveandlightcurebulkfillcompositeresins AT alhajalisanaan thicknessdependentlighttransmittanceandtemperatureriseindualcurebioactiveandlightcurebulkfillcompositeresins AT farahrafati thicknessdependentlighttransmittanceandtemperatureriseindualcurebioactiveandlightcurebulkfillcompositeresins |