Cargando…
Aberration correction in 2D echocardiography
BACKGROUND: An aberration correction algorithm has been implemented and demonstrated in an echocardiographic clinical trial using two-dimensional (2D) imaging. The method estimates and compensates arrival time errors between different sub-aperture processor (SAP) signals in a matrix array probe. MET...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10347361/ https://www.ncbi.nlm.nih.gov/pubmed/37456280 http://dx.doi.org/10.21037/qims-22-895 |
_version_ | 1785073532169879552 |
---|---|
author | Måsøy, Svein-Erik Dénarié, Bastien Sørnes, Anders Holte, Espen Grenne, Bjørnar Espeland, Torvald Berg, Erik Andreas Rye Rindal, Ole Marius Hoel Rigby, Wayne Bjåstad, Tore |
author_facet | Måsøy, Svein-Erik Dénarié, Bastien Sørnes, Anders Holte, Espen Grenne, Bjørnar Espeland, Torvald Berg, Erik Andreas Rye Rindal, Ole Marius Hoel Rigby, Wayne Bjåstad, Tore |
author_sort | Måsøy, Svein-Erik |
collection | PubMed |
description | BACKGROUND: An aberration correction algorithm has been implemented and demonstrated in an echocardiographic clinical trial using two-dimensional (2D) imaging. The method estimates and compensates arrival time errors between different sub-aperture processor (SAP) signals in a matrix array probe. METHODS: Five standard views of channel data cineloops were recorded from 22 patients (11 male and 11 female) resulting in a total of 116 cineloops. The channel data were processed with and without the aberration correction algorithm, allowing for side-by-side comparison of images processed from the same channel data cineloops. RESULTS: The aberration correction algorithm improved image quality, as quantified by a coherence metric, in all 7,380 processed frames. In a blinded and left-right-randomized side-by-side evaluation, four cardiologists (two experienced and two in training) preferred the aberration corrected cineloops in 97% of the cases. The clinicians reported that the corrected cineloops appeared sharper with better contrast and less noise. Many structures like valve leaflets, chordae, endocardium, and endocardial borders appeared narrower and more clearly defined in the aberration corrected images. An important finding is that aberration correction improves contrast between the endocardium and ventricle cavities for every processed image. The gain difference was confirmed by the cardiologists in their feedback and quantified with a median global gain difference estimate between the aberration-corrected and non-corrected images of 1.2 dB. CONCLUSIONS: The study shows the potential value of aberration correction in clinical echocardiography. Systematic improvement of images acquired with state-of-art equipment was observed both with quantitative metrics of image quality and clinician preference. |
format | Online Article Text |
id | pubmed-10347361 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-103473612023-07-15 Aberration correction in 2D echocardiography Måsøy, Svein-Erik Dénarié, Bastien Sørnes, Anders Holte, Espen Grenne, Bjørnar Espeland, Torvald Berg, Erik Andreas Rye Rindal, Ole Marius Hoel Rigby, Wayne Bjåstad, Tore Quant Imaging Med Surg Original Article BACKGROUND: An aberration correction algorithm has been implemented and demonstrated in an echocardiographic clinical trial using two-dimensional (2D) imaging. The method estimates and compensates arrival time errors between different sub-aperture processor (SAP) signals in a matrix array probe. METHODS: Five standard views of channel data cineloops were recorded from 22 patients (11 male and 11 female) resulting in a total of 116 cineloops. The channel data were processed with and without the aberration correction algorithm, allowing for side-by-side comparison of images processed from the same channel data cineloops. RESULTS: The aberration correction algorithm improved image quality, as quantified by a coherence metric, in all 7,380 processed frames. In a blinded and left-right-randomized side-by-side evaluation, four cardiologists (two experienced and two in training) preferred the aberration corrected cineloops in 97% of the cases. The clinicians reported that the corrected cineloops appeared sharper with better contrast and less noise. Many structures like valve leaflets, chordae, endocardium, and endocardial borders appeared narrower and more clearly defined in the aberration corrected images. An important finding is that aberration correction improves contrast between the endocardium and ventricle cavities for every processed image. The gain difference was confirmed by the cardiologists in their feedback and quantified with a median global gain difference estimate between the aberration-corrected and non-corrected images of 1.2 dB. CONCLUSIONS: The study shows the potential value of aberration correction in clinical echocardiography. Systematic improvement of images acquired with state-of-art equipment was observed both with quantitative metrics of image quality and clinician preference. AME Publishing Company 2023-05-30 2023-07-01 /pmc/articles/PMC10347361/ /pubmed/37456280 http://dx.doi.org/10.21037/qims-22-895 Text en 2023 Quantitative Imaging in Medicine and Surgery. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Original Article Måsøy, Svein-Erik Dénarié, Bastien Sørnes, Anders Holte, Espen Grenne, Bjørnar Espeland, Torvald Berg, Erik Andreas Rye Rindal, Ole Marius Hoel Rigby, Wayne Bjåstad, Tore Aberration correction in 2D echocardiography |
title | Aberration correction in 2D echocardiography |
title_full | Aberration correction in 2D echocardiography |
title_fullStr | Aberration correction in 2D echocardiography |
title_full_unstemmed | Aberration correction in 2D echocardiography |
title_short | Aberration correction in 2D echocardiography |
title_sort | aberration correction in 2d echocardiography |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10347361/ https://www.ncbi.nlm.nih.gov/pubmed/37456280 http://dx.doi.org/10.21037/qims-22-895 |
work_keys_str_mv | AT masøysveinerik aberrationcorrectionin2dechocardiography AT denariebastien aberrationcorrectionin2dechocardiography AT sørnesanders aberrationcorrectionin2dechocardiography AT holteespen aberrationcorrectionin2dechocardiography AT grennebjørnar aberrationcorrectionin2dechocardiography AT espelandtorvald aberrationcorrectionin2dechocardiography AT bergerikandreasrye aberrationcorrectionin2dechocardiography AT rindalolemariushoel aberrationcorrectionin2dechocardiography AT rigbywayne aberrationcorrectionin2dechocardiography AT bjastadtore aberrationcorrectionin2dechocardiography |