Cargando…
Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation
OBJECTIVE: To evaluate the influence of pilocarpine eyedrops on the ocular biometric parameters and whether these parameter changes affect the intraocular lens (IOL) power calculation in patients with primary angle-closure glaucoma (PACG). METHODS: Twenty-two PACG patients and fifteen normal subject...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10348856/ https://www.ncbi.nlm.nih.gov/pubmed/37455794 http://dx.doi.org/10.1155/2023/7680659 |
_version_ | 1785073752128618496 |
---|---|
author | Gao, Ruxin Liu, Jinkun Zhou, Xiaojie Huang, Luping Huang, Weiyi Xue, Yingying Wang, Fei Gong, Songjian Wu, Renyi Wang, Yuhong |
author_facet | Gao, Ruxin Liu, Jinkun Zhou, Xiaojie Huang, Luping Huang, Weiyi Xue, Yingying Wang, Fei Gong, Songjian Wu, Renyi Wang, Yuhong |
author_sort | Gao, Ruxin |
collection | PubMed |
description | OBJECTIVE: To evaluate the influence of pilocarpine eyedrops on the ocular biometric parameters and whether these parameter changes affect the intraocular lens (IOL) power calculation in patients with primary angle-closure glaucoma (PACG). METHODS: Twenty-two PACG patients and fifteen normal subjects were enrolled. Ocular biometric parameters including the axial length (AL), anterior chamber depth (ACD), lens thickness (LT), mean keratometry (Km), and white-to-white distance (WTW) were measured by using a Lenstar LS 900 device before and at least 30 minutes after instillation of 2% pilocarpine eyedrops. Lens position (LP) was calculated, and the IOL power prediction based on the ocular biometric parameters was performed using the Barrett Universal II, Haigis, Hoffer Q, Holladay I, or SRK/T formulas before and after pilocarpine application. RESULTS: In both PACG and normal groups, pilocarpine eyedrops induced a slight but statistically significant increase in the mean AL (0.01 mm for both groups) and mean LT (0.02 mm and 0.03 mm, respectively) but a significant decrease in the mean ACD (0.03 mm and 0.05 mm, respectively) and mean LP (0.02 mm and 0.04 mm, respectively). No significant changes in the mean Km and WTW were noticed in both groups. In addition, the IOL power calculation revealed insignificant changes before and after the pilocarpine instillation in both groups, regardless of the formula used. CONCLUSIONS: Pilocarpine eyedrops can induce slight changes in the ocular biometric parameters including the AL, ACD, LT, and LP. However, these parameter changes will not result in a significant difference in IOL power estimation. |
format | Online Article Text |
id | pubmed-10348856 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-103488562023-07-15 Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation Gao, Ruxin Liu, Jinkun Zhou, Xiaojie Huang, Luping Huang, Weiyi Xue, Yingying Wang, Fei Gong, Songjian Wu, Renyi Wang, Yuhong J Ophthalmol Research Article OBJECTIVE: To evaluate the influence of pilocarpine eyedrops on the ocular biometric parameters and whether these parameter changes affect the intraocular lens (IOL) power calculation in patients with primary angle-closure glaucoma (PACG). METHODS: Twenty-two PACG patients and fifteen normal subjects were enrolled. Ocular biometric parameters including the axial length (AL), anterior chamber depth (ACD), lens thickness (LT), mean keratometry (Km), and white-to-white distance (WTW) were measured by using a Lenstar LS 900 device before and at least 30 minutes after instillation of 2% pilocarpine eyedrops. Lens position (LP) was calculated, and the IOL power prediction based on the ocular biometric parameters was performed using the Barrett Universal II, Haigis, Hoffer Q, Holladay I, or SRK/T formulas before and after pilocarpine application. RESULTS: In both PACG and normal groups, pilocarpine eyedrops induced a slight but statistically significant increase in the mean AL (0.01 mm for both groups) and mean LT (0.02 mm and 0.03 mm, respectively) but a significant decrease in the mean ACD (0.03 mm and 0.05 mm, respectively) and mean LP (0.02 mm and 0.04 mm, respectively). No significant changes in the mean Km and WTW were noticed in both groups. In addition, the IOL power calculation revealed insignificant changes before and after the pilocarpine instillation in both groups, regardless of the formula used. CONCLUSIONS: Pilocarpine eyedrops can induce slight changes in the ocular biometric parameters including the AL, ACD, LT, and LP. However, these parameter changes will not result in a significant difference in IOL power estimation. Hindawi 2023-07-07 /pmc/articles/PMC10348856/ /pubmed/37455794 http://dx.doi.org/10.1155/2023/7680659 Text en Copyright © 2023 Ruxin Gao et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Gao, Ruxin Liu, Jinkun Zhou, Xiaojie Huang, Luping Huang, Weiyi Xue, Yingying Wang, Fei Gong, Songjian Wu, Renyi Wang, Yuhong Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation |
title | Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation |
title_full | Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation |
title_fullStr | Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation |
title_full_unstemmed | Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation |
title_short | Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation |
title_sort | influence of pilocarpine eyedrops on the ocular biometric parameters and intraocular lens power calculation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10348856/ https://www.ncbi.nlm.nih.gov/pubmed/37455794 http://dx.doi.org/10.1155/2023/7680659 |
work_keys_str_mv | AT gaoruxin influenceofpilocarpineeyedropsontheocularbiometricparametersandintraocularlenspowercalculation AT liujinkun influenceofpilocarpineeyedropsontheocularbiometricparametersandintraocularlenspowercalculation AT zhouxiaojie influenceofpilocarpineeyedropsontheocularbiometricparametersandintraocularlenspowercalculation AT huangluping influenceofpilocarpineeyedropsontheocularbiometricparametersandintraocularlenspowercalculation AT huangweiyi influenceofpilocarpineeyedropsontheocularbiometricparametersandintraocularlenspowercalculation AT xueyingying influenceofpilocarpineeyedropsontheocularbiometricparametersandintraocularlenspowercalculation AT wangfei influenceofpilocarpineeyedropsontheocularbiometricparametersandintraocularlenspowercalculation AT gongsongjian influenceofpilocarpineeyedropsontheocularbiometricparametersandintraocularlenspowercalculation AT wurenyi influenceofpilocarpineeyedropsontheocularbiometricparametersandintraocularlenspowercalculation AT wangyuhong influenceofpilocarpineeyedropsontheocularbiometricparametersandintraocularlenspowercalculation |