Cargando…

Bubble Cloud Characteristics and Ablation Efficiency in Dual-Frequency Intrinsic Threshold Histotripsy

Histotripsy is a non-thermal focused ultrasound ablation method that destroys tissue through the generation and activity of acoustic cavitation bubble clouds. Intrinsic threshold histotripsy uses single-cycle pulses to generate bubble clouds when the dominant negative pressure phase exceeds an intri...

Descripción completa

Detalles Bibliográficos
Autores principales: Edsall, Connor, Huynh, Laura, Hall, Tim, Vlaisavljevich, Eli
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cornell University 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10350103/
https://www.ncbi.nlm.nih.gov/pubmed/37461413
_version_ 1785074059313152000
author Edsall, Connor
Huynh, Laura
Hall, Tim
Vlaisavljevich, Eli
author_facet Edsall, Connor
Huynh, Laura
Hall, Tim
Vlaisavljevich, Eli
author_sort Edsall, Connor
collection PubMed
description Histotripsy is a non-thermal focused ultrasound ablation method that destroys tissue through the generation and activity of acoustic cavitation bubble clouds. Intrinsic threshold histotripsy uses single-cycle pulses to generate bubble clouds when the dominant negative pressure phase exceeds an intrinsic threshold of ~25–30 MPa. The ablation efficiency is dependent upon the size and density of bubbles within the bubble cloud. This work investigates the effects of dual-frequency pulsing schemes on the bubble cloud behavior and ablation efficiency in intrinsic threshold histotripsy. A modular 500 kHz:3 MHz histotripsy transducer treated agarose phantoms using dual-frequency histotripsy pulses with a 1:1 pressure ratio from 500 kHz and 3 MHz frequency elements and varying arrival times for the 3 MHz pulse relative to the arrival of the 500 kHz pulse (−100 ns, 0 ns, and +100 ns). High-speed optical imaging captured cavitation effects to characterize bubble cloud and individual bubble dynamics. The effects of dual-frequency pulsing on lesion formation and ablation efficiency were also investigated in red blood cell (RBC) phantoms. Results showed that the single bubble and bubble cloud size for dual-frequency cases were intermediate to published results for the component single frequencies of 500 kHz and 3 MHz. Additionally, bubble cloud size and dynamics were shown to be altered by the arrival time of the 3 MHz pulse with respect to the 500 kHz pulse, with more uniform cloud expansion and collapse observed for early (−100 ns) arrival. Finally, RBC phantom experiments showed that dual-frequency exposures were capable of generating precise lesions with smaller areas and higher ablation efficiencies than previously published results for 500 kHz or 3 MHz. Overall, results demonstrate dual-frequency histotripsy’s ability to modulate bubble cloud size and dynamics can be leveraged to produce precise lesions at higher ablation efficiencies than previously observed for single-frequency pulsing.
format Online
Article
Text
id pubmed-10350103
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cornell University
record_format MEDLINE/PubMed
spelling pubmed-103501032023-07-17 Bubble Cloud Characteristics and Ablation Efficiency in Dual-Frequency Intrinsic Threshold Histotripsy Edsall, Connor Huynh, Laura Hall, Tim Vlaisavljevich, Eli ArXiv Article Histotripsy is a non-thermal focused ultrasound ablation method that destroys tissue through the generation and activity of acoustic cavitation bubble clouds. Intrinsic threshold histotripsy uses single-cycle pulses to generate bubble clouds when the dominant negative pressure phase exceeds an intrinsic threshold of ~25–30 MPa. The ablation efficiency is dependent upon the size and density of bubbles within the bubble cloud. This work investigates the effects of dual-frequency pulsing schemes on the bubble cloud behavior and ablation efficiency in intrinsic threshold histotripsy. A modular 500 kHz:3 MHz histotripsy transducer treated agarose phantoms using dual-frequency histotripsy pulses with a 1:1 pressure ratio from 500 kHz and 3 MHz frequency elements and varying arrival times for the 3 MHz pulse relative to the arrival of the 500 kHz pulse (−100 ns, 0 ns, and +100 ns). High-speed optical imaging captured cavitation effects to characterize bubble cloud and individual bubble dynamics. The effects of dual-frequency pulsing on lesion formation and ablation efficiency were also investigated in red blood cell (RBC) phantoms. Results showed that the single bubble and bubble cloud size for dual-frequency cases were intermediate to published results for the component single frequencies of 500 kHz and 3 MHz. Additionally, bubble cloud size and dynamics were shown to be altered by the arrival time of the 3 MHz pulse with respect to the 500 kHz pulse, with more uniform cloud expansion and collapse observed for early (−100 ns) arrival. Finally, RBC phantom experiments showed that dual-frequency exposures were capable of generating precise lesions with smaller areas and higher ablation efficiencies than previously published results for 500 kHz or 3 MHz. Overall, results demonstrate dual-frequency histotripsy’s ability to modulate bubble cloud size and dynamics can be leveraged to produce precise lesions at higher ablation efficiencies than previously observed for single-frequency pulsing. Cornell University 2023-07-06 /pmc/articles/PMC10350103/ /pubmed/37461413 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which allows reusers to copy and distribute the material in any medium or format in unadapted form only, for noncommercial purposes only, and only so long as attribution is given to the creator.
spellingShingle Article
Edsall, Connor
Huynh, Laura
Hall, Tim
Vlaisavljevich, Eli
Bubble Cloud Characteristics and Ablation Efficiency in Dual-Frequency Intrinsic Threshold Histotripsy
title Bubble Cloud Characteristics and Ablation Efficiency in Dual-Frequency Intrinsic Threshold Histotripsy
title_full Bubble Cloud Characteristics and Ablation Efficiency in Dual-Frequency Intrinsic Threshold Histotripsy
title_fullStr Bubble Cloud Characteristics and Ablation Efficiency in Dual-Frequency Intrinsic Threshold Histotripsy
title_full_unstemmed Bubble Cloud Characteristics and Ablation Efficiency in Dual-Frequency Intrinsic Threshold Histotripsy
title_short Bubble Cloud Characteristics and Ablation Efficiency in Dual-Frequency Intrinsic Threshold Histotripsy
title_sort bubble cloud characteristics and ablation efficiency in dual-frequency intrinsic threshold histotripsy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10350103/
https://www.ncbi.nlm.nih.gov/pubmed/37461413
work_keys_str_mv AT edsallconnor bubblecloudcharacteristicsandablationefficiencyindualfrequencyintrinsicthresholdhistotripsy
AT huynhlaura bubblecloudcharacteristicsandablationefficiencyindualfrequencyintrinsicthresholdhistotripsy
AT halltim bubblecloudcharacteristicsandablationefficiencyindualfrequencyintrinsicthresholdhistotripsy
AT vlaisavljevicheli bubblecloudcharacteristicsandablationefficiencyindualfrequencyintrinsicthresholdhistotripsy