Cargando…

Contact time has limited impact on the efficacy of disinfectant towelettes when tested under conditions reflective of realistic use

BACKGROUND: Disinfectant towelettes are increasingly being used as a means to prevent transmission of clinically important pathogens which could lead to healthcare-associated infections (HAIs). However, the efficacy of disinfectant towelette products when tested under realistic use conditions is und...

Descripción completa

Detalles Bibliográficos
Autores principales: Kelley, Alyssa M., Voorn, Maxwell G., Tembo, Geraldine M., Horn, Connor M., Li, Xiaobao, Teska, Peter J., Oliver, Haley F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10350269/
https://www.ncbi.nlm.nih.gov/pubmed/37455322
http://dx.doi.org/10.1186/s13756-023-01266-4
Descripción
Sumario:BACKGROUND: Disinfectant towelettes are increasingly being used as a means to prevent transmission of clinically important pathogens which could lead to healthcare-associated infections (HAIs). However, the efficacy of disinfectant towelette products when tested under realistic use conditions is understudied. A test model was designed to replicate realistic wiping conditions. The objective of this study was to determine the impact of varied contact time on disinfectant towelette efficacy under these conditions. METHODS: Five product types were tested against Staphylococcus aureus (ATCC 6538) and Pseudomonas aeruginosa (ATCC 15,442) at five contact times (30 s, one min, two min, three min, and 10 min) on hard, non-porous laminate templates to determine the impact of contact time on disinfectant towelette efficacy when tested under realistic use. RESULTS: Product type had a significant impact on the efficacy of disinfectant towelettes when tested under conditions reflective of realistic use. The effect of contact time was limited and no differences in efficacy were seen at a contact time of one min compared with the other contact times tested. Only one disinfectant towelette product achieved a mean 5-log reduction under the tested conditions. CONCLUSION: Efficacy of disinfectant towelettes was primarily impacted by product type when applied in a model designed to replicate realistic use in which only a limited effect of contact time was observed. There is a need for further investigation into which factors have the greatest impact on disinfectant towelette efficacy when applied in clinical settings.