Swimming With Sharks: Left Main Coronary Obstruction Following Transcatheter Aortic Valve Implantation

Delayed coronary obstruction (DCO) occurs when there is obstruction of the coronary ostia following a transcatheter aortic valvular implantation (TAVI). It is an uncommon but serious complication that often leads to death, usually presents as severe hypotension after TAVI, and should be suspected if...

Descripción completa

Detalles Bibliográficos
Autores principales: Barrera, Nelson, Gallegos, Francisco, Chamay, Salomon, Cerrud-Rodriguez, Roberto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10350300/
https://www.ncbi.nlm.nih.gov/pubmed/37461763
http://dx.doi.org/10.7759/cureus.40514
_version_ 1785074106918502400
author Barrera, Nelson
Gallegos, Francisco
Chamay, Salomon
Cerrud-Rodriguez, Roberto
author_facet Barrera, Nelson
Gallegos, Francisco
Chamay, Salomon
Cerrud-Rodriguez, Roberto
author_sort Barrera, Nelson
collection PubMed
description Delayed coronary obstruction (DCO) occurs when there is obstruction of the coronary ostia following a transcatheter aortic valvular implantation (TAVI). It is an uncommon but serious complication that often leads to death, usually presents as severe hypotension after TAVI, and should be suspected if migration of the valve occurs. We report the case of a 70-year-old female patient with severe aortic stenosis who underwent TAVI using a 26-mm CoreValve Evolut Pro (Medtronic, Dublin, Ireland). Although the valve was implanted successfully, she experienced hypotension with intermittent ST elevations and had a cardiac arrest shortly after, requiring Advanced Cardiovascular Life Support (ACLS). An aortogram showed sealing of the sinotubular junction (STJ) by CoreValve, without coronary flow. CoreValve was then snared and repositioned in the ascending aorta recovering coronary flow and cardiac pulsatility. A second TAVI was performed and an Edwards 20 mm Sapiens 3 valve (Edwards Lifesciences, Irvine, CA, USA) was implanted as standard procedure.
format Online
Article
Text
id pubmed-10350300
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-103503002023-07-17 Swimming With Sharks: Left Main Coronary Obstruction Following Transcatheter Aortic Valve Implantation Barrera, Nelson Gallegos, Francisco Chamay, Salomon Cerrud-Rodriguez, Roberto Cureus Cardiac/Thoracic/Vascular Surgery Delayed coronary obstruction (DCO) occurs when there is obstruction of the coronary ostia following a transcatheter aortic valvular implantation (TAVI). It is an uncommon but serious complication that often leads to death, usually presents as severe hypotension after TAVI, and should be suspected if migration of the valve occurs. We report the case of a 70-year-old female patient with severe aortic stenosis who underwent TAVI using a 26-mm CoreValve Evolut Pro (Medtronic, Dublin, Ireland). Although the valve was implanted successfully, she experienced hypotension with intermittent ST elevations and had a cardiac arrest shortly after, requiring Advanced Cardiovascular Life Support (ACLS). An aortogram showed sealing of the sinotubular junction (STJ) by CoreValve, without coronary flow. CoreValve was then snared and repositioned in the ascending aorta recovering coronary flow and cardiac pulsatility. A second TAVI was performed and an Edwards 20 mm Sapiens 3 valve (Edwards Lifesciences, Irvine, CA, USA) was implanted as standard procedure. Cureus 2023-06-16 /pmc/articles/PMC10350300/ /pubmed/37461763 http://dx.doi.org/10.7759/cureus.40514 Text en Copyright © 2023, Barrera et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Cardiac/Thoracic/Vascular Surgery
Barrera, Nelson
Gallegos, Francisco
Chamay, Salomon
Cerrud-Rodriguez, Roberto
Swimming With Sharks: Left Main Coronary Obstruction Following Transcatheter Aortic Valve Implantation
title Swimming With Sharks: Left Main Coronary Obstruction Following Transcatheter Aortic Valve Implantation
title_full Swimming With Sharks: Left Main Coronary Obstruction Following Transcatheter Aortic Valve Implantation
title_fullStr Swimming With Sharks: Left Main Coronary Obstruction Following Transcatheter Aortic Valve Implantation
title_full_unstemmed Swimming With Sharks: Left Main Coronary Obstruction Following Transcatheter Aortic Valve Implantation
title_short Swimming With Sharks: Left Main Coronary Obstruction Following Transcatheter Aortic Valve Implantation
title_sort swimming with sharks: left main coronary obstruction following transcatheter aortic valve implantation
topic Cardiac/Thoracic/Vascular Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10350300/
https://www.ncbi.nlm.nih.gov/pubmed/37461763
http://dx.doi.org/10.7759/cureus.40514
work_keys_str_mv AT barreranelson swimmingwithsharksleftmaincoronaryobstructionfollowingtranscatheteraorticvalveimplantation
AT gallegosfrancisco swimmingwithsharksleftmaincoronaryobstructionfollowingtranscatheteraorticvalveimplantation
AT chamaysalomon swimmingwithsharksleftmaincoronaryobstructionfollowingtranscatheteraorticvalveimplantation
AT cerrudrodriguezroberto swimmingwithsharksleftmaincoronaryobstructionfollowingtranscatheteraorticvalveimplantation