Cargando…
Swimming With Sharks: Left Main Coronary Obstruction Following Transcatheter Aortic Valve Implantation
Delayed coronary obstruction (DCO) occurs when there is obstruction of the coronary ostia following a transcatheter aortic valvular implantation (TAVI). It is an uncommon but serious complication that often leads to death, usually presents as severe hypotension after TAVI, and should be suspected if...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10350300/ https://www.ncbi.nlm.nih.gov/pubmed/37461763 http://dx.doi.org/10.7759/cureus.40514 |
_version_ | 1785074106918502400 |
---|---|
author | Barrera, Nelson Gallegos, Francisco Chamay, Salomon Cerrud-Rodriguez, Roberto |
author_facet | Barrera, Nelson Gallegos, Francisco Chamay, Salomon Cerrud-Rodriguez, Roberto |
author_sort | Barrera, Nelson |
collection | PubMed |
description | Delayed coronary obstruction (DCO) occurs when there is obstruction of the coronary ostia following a transcatheter aortic valvular implantation (TAVI). It is an uncommon but serious complication that often leads to death, usually presents as severe hypotension after TAVI, and should be suspected if migration of the valve occurs. We report the case of a 70-year-old female patient with severe aortic stenosis who underwent TAVI using a 26-mm CoreValve Evolut Pro (Medtronic, Dublin, Ireland). Although the valve was implanted successfully, she experienced hypotension with intermittent ST elevations and had a cardiac arrest shortly after, requiring Advanced Cardiovascular Life Support (ACLS). An aortogram showed sealing of the sinotubular junction (STJ) by CoreValve, without coronary flow. CoreValve was then snared and repositioned in the ascending aorta recovering coronary flow and cardiac pulsatility. A second TAVI was performed and an Edwards 20 mm Sapiens 3 valve (Edwards Lifesciences, Irvine, CA, USA) was implanted as standard procedure. |
format | Online Article Text |
id | pubmed-10350300 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-103503002023-07-17 Swimming With Sharks: Left Main Coronary Obstruction Following Transcatheter Aortic Valve Implantation Barrera, Nelson Gallegos, Francisco Chamay, Salomon Cerrud-Rodriguez, Roberto Cureus Cardiac/Thoracic/Vascular Surgery Delayed coronary obstruction (DCO) occurs when there is obstruction of the coronary ostia following a transcatheter aortic valvular implantation (TAVI). It is an uncommon but serious complication that often leads to death, usually presents as severe hypotension after TAVI, and should be suspected if migration of the valve occurs. We report the case of a 70-year-old female patient with severe aortic stenosis who underwent TAVI using a 26-mm CoreValve Evolut Pro (Medtronic, Dublin, Ireland). Although the valve was implanted successfully, she experienced hypotension with intermittent ST elevations and had a cardiac arrest shortly after, requiring Advanced Cardiovascular Life Support (ACLS). An aortogram showed sealing of the sinotubular junction (STJ) by CoreValve, without coronary flow. CoreValve was then snared and repositioned in the ascending aorta recovering coronary flow and cardiac pulsatility. A second TAVI was performed and an Edwards 20 mm Sapiens 3 valve (Edwards Lifesciences, Irvine, CA, USA) was implanted as standard procedure. Cureus 2023-06-16 /pmc/articles/PMC10350300/ /pubmed/37461763 http://dx.doi.org/10.7759/cureus.40514 Text en Copyright © 2023, Barrera et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Cardiac/Thoracic/Vascular Surgery Barrera, Nelson Gallegos, Francisco Chamay, Salomon Cerrud-Rodriguez, Roberto Swimming With Sharks: Left Main Coronary Obstruction Following Transcatheter Aortic Valve Implantation |
title | Swimming With Sharks: Left Main Coronary Obstruction Following Transcatheter Aortic Valve Implantation |
title_full | Swimming With Sharks: Left Main Coronary Obstruction Following Transcatheter Aortic Valve Implantation |
title_fullStr | Swimming With Sharks: Left Main Coronary Obstruction Following Transcatheter Aortic Valve Implantation |
title_full_unstemmed | Swimming With Sharks: Left Main Coronary Obstruction Following Transcatheter Aortic Valve Implantation |
title_short | Swimming With Sharks: Left Main Coronary Obstruction Following Transcatheter Aortic Valve Implantation |
title_sort | swimming with sharks: left main coronary obstruction following transcatheter aortic valve implantation |
topic | Cardiac/Thoracic/Vascular Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10350300/ https://www.ncbi.nlm.nih.gov/pubmed/37461763 http://dx.doi.org/10.7759/cureus.40514 |
work_keys_str_mv | AT barreranelson swimmingwithsharksleftmaincoronaryobstructionfollowingtranscatheteraorticvalveimplantation AT gallegosfrancisco swimmingwithsharksleftmaincoronaryobstructionfollowingtranscatheteraorticvalveimplantation AT chamaysalomon swimmingwithsharksleftmaincoronaryobstructionfollowingtranscatheteraorticvalveimplantation AT cerrudrodriguezroberto swimmingwithsharksleftmaincoronaryobstructionfollowingtranscatheteraorticvalveimplantation |