Cargando…

Reliability of Cone Beam Weightbearing Computed Tomography Analysis of Total Ankle Arthroplasty Positioning and Comparison to Weightbearing X-Ray Measurements

BACKGROUND: The current reference standard for postoperative evaluation of total ankle arthroplasty (TAA) positioning, weightbearing radiography (WBXR), is subject to technical bias. Weightbearing cone beam computed tomography (WBCT) enables visualization of the foot’s complex 3-dimensional (3D) str...

Descripción completa

Detalles Bibliográficos
Autores principales: Efrima, Ben, Barbero, Agustin, Ovadia, Joshua E., Indino, Cristian, Maccario, Camilla, Usuelli, Federico Giuseppe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10350699/
https://www.ncbi.nlm.nih.gov/pubmed/37231710
http://dx.doi.org/10.1177/10711007231173672
_version_ 1785074190391443456
author Efrima, Ben
Barbero, Agustin
Ovadia, Joshua E.
Indino, Cristian
Maccario, Camilla
Usuelli, Federico Giuseppe
author_facet Efrima, Ben
Barbero, Agustin
Ovadia, Joshua E.
Indino, Cristian
Maccario, Camilla
Usuelli, Federico Giuseppe
author_sort Efrima, Ben
collection PubMed
description BACKGROUND: The current reference standard for postoperative evaluation of total ankle arthroplasty (TAA) positioning, weightbearing radiography (WBXR), is subject to technical bias. Weightbearing cone beam computed tomography (WBCT) enables visualization of the foot’s complex 3-dimensional (3D) structure under standing load. To date, no WBCT-based system for TAA positioning has been validated. The purpose of this study was to (1) assess TAA positioning using WBCT 3D models and (2) evaluate the agreement levels between 2 raters and thus evaluate the intermethod reliability with respect to WBXR. METHODS: Fifty-five consecutive patients were retrospectively reviewed. Two raters independently created a 3D WBCT model using dedicated software and recorded the following measurements: α angle, tibiotalar surface angle (TSA), hindfoot angle (HFA), tibiotalar ratio (TTR), β angle, γ angle, and Φ angle. Measurements were repeated 2 months apart in similar, independent fashion and compared to WBXR. Interobserver, intraobserver, and intermethod agreements were calculated. RESULTS: All 7 measurements showed good to excellent intraobserver and interobserver reliability (ICC 0.85-0.95). The intermethod (WBCT vs WBXR) agreement showed good agreement for the γ angle (ICC 0.79); moderate agreement levels for the α angle, TSA angle, β angle, and TTR (ICC 0.68, 0.69, 0.70, and 0.69, respectively); poor agreement for the HFA (ICC 0.25); and negative agreement for the φ angle (ICC −0.2). CONCLUSION: Position analysis of TAA using WBCT demonstrated good to excellent interobserver and intraobserver agreement and can be reliably used. Additionally, a negative to moderate agreement between standard WBCT and standard WBXR was found. LEVEL OF EVIDENCE: Level III, retrospective study.
format Online
Article
Text
id pubmed-10350699
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-103506992023-07-18 Reliability of Cone Beam Weightbearing Computed Tomography Analysis of Total Ankle Arthroplasty Positioning and Comparison to Weightbearing X-Ray Measurements Efrima, Ben Barbero, Agustin Ovadia, Joshua E. Indino, Cristian Maccario, Camilla Usuelli, Federico Giuseppe Foot Ankle Int Articles BACKGROUND: The current reference standard for postoperative evaluation of total ankle arthroplasty (TAA) positioning, weightbearing radiography (WBXR), is subject to technical bias. Weightbearing cone beam computed tomography (WBCT) enables visualization of the foot’s complex 3-dimensional (3D) structure under standing load. To date, no WBCT-based system for TAA positioning has been validated. The purpose of this study was to (1) assess TAA positioning using WBCT 3D models and (2) evaluate the agreement levels between 2 raters and thus evaluate the intermethod reliability with respect to WBXR. METHODS: Fifty-five consecutive patients were retrospectively reviewed. Two raters independently created a 3D WBCT model using dedicated software and recorded the following measurements: α angle, tibiotalar surface angle (TSA), hindfoot angle (HFA), tibiotalar ratio (TTR), β angle, γ angle, and Φ angle. Measurements were repeated 2 months apart in similar, independent fashion and compared to WBXR. Interobserver, intraobserver, and intermethod agreements were calculated. RESULTS: All 7 measurements showed good to excellent intraobserver and interobserver reliability (ICC 0.85-0.95). The intermethod (WBCT vs WBXR) agreement showed good agreement for the γ angle (ICC 0.79); moderate agreement levels for the α angle, TSA angle, β angle, and TTR (ICC 0.68, 0.69, 0.70, and 0.69, respectively); poor agreement for the HFA (ICC 0.25); and negative agreement for the φ angle (ICC −0.2). CONCLUSION: Position analysis of TAA using WBCT demonstrated good to excellent interobserver and intraobserver agreement and can be reliably used. Additionally, a negative to moderate agreement between standard WBCT and standard WBXR was found. LEVEL OF EVIDENCE: Level III, retrospective study. SAGE Publications 2023-05-26 2023-07 /pmc/articles/PMC10350699/ /pubmed/37231710 http://dx.doi.org/10.1177/10711007231173672 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Articles
Efrima, Ben
Barbero, Agustin
Ovadia, Joshua E.
Indino, Cristian
Maccario, Camilla
Usuelli, Federico Giuseppe
Reliability of Cone Beam Weightbearing Computed Tomography Analysis of Total Ankle Arthroplasty Positioning and Comparison to Weightbearing X-Ray Measurements
title Reliability of Cone Beam Weightbearing Computed Tomography Analysis of Total Ankle Arthroplasty Positioning and Comparison to Weightbearing X-Ray Measurements
title_full Reliability of Cone Beam Weightbearing Computed Tomography Analysis of Total Ankle Arthroplasty Positioning and Comparison to Weightbearing X-Ray Measurements
title_fullStr Reliability of Cone Beam Weightbearing Computed Tomography Analysis of Total Ankle Arthroplasty Positioning and Comparison to Weightbearing X-Ray Measurements
title_full_unstemmed Reliability of Cone Beam Weightbearing Computed Tomography Analysis of Total Ankle Arthroplasty Positioning and Comparison to Weightbearing X-Ray Measurements
title_short Reliability of Cone Beam Weightbearing Computed Tomography Analysis of Total Ankle Arthroplasty Positioning and Comparison to Weightbearing X-Ray Measurements
title_sort reliability of cone beam weightbearing computed tomography analysis of total ankle arthroplasty positioning and comparison to weightbearing x-ray measurements
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10350699/
https://www.ncbi.nlm.nih.gov/pubmed/37231710
http://dx.doi.org/10.1177/10711007231173672
work_keys_str_mv AT efrimaben reliabilityofconebeamweightbearingcomputedtomographyanalysisoftotalanklearthroplastypositioningandcomparisontoweightbearingxraymeasurements
AT barberoagustin reliabilityofconebeamweightbearingcomputedtomographyanalysisoftotalanklearthroplastypositioningandcomparisontoweightbearingxraymeasurements
AT ovadiajoshuae reliabilityofconebeamweightbearingcomputedtomographyanalysisoftotalanklearthroplastypositioningandcomparisontoweightbearingxraymeasurements
AT indinocristian reliabilityofconebeamweightbearingcomputedtomographyanalysisoftotalanklearthroplastypositioningandcomparisontoweightbearingxraymeasurements
AT maccariocamilla reliabilityofconebeamweightbearingcomputedtomographyanalysisoftotalanklearthroplastypositioningandcomparisontoweightbearingxraymeasurements
AT usuellifedericogiuseppe reliabilityofconebeamweightbearingcomputedtomographyanalysisoftotalanklearthroplastypositioningandcomparisontoweightbearingxraymeasurements