Midterm Outcomes of BeGraft Stent Grafts Used as Bridging Stents in Fenestrated Endovascular Aortic Aneurysm Repair

PURPOSE: Fenestrated endovascular aneurysm repair (fEVAR) is established for the treatment of juxtarenal, pararenal, and thoracoabdominal aortic aneurysms (TAAAs). Bridging stents are used to connect the main body of the stent graft to the aortic branch vessels. Complications related to the bridging...

Descripción completa

Detalles Bibliográficos
Autores principales: Clough, Rachel E., Spear, Rafaëlle, Mougin, Justine, Le Houérou, Thomas, Fabre, Dominique, Sobocinski, Jonathan, Haulon, Stéphan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10350705/
https://www.ncbi.nlm.nih.gov/pubmed/35471131
http://dx.doi.org/10.1177/15266028221091894
_version_ 1785074191891955712
author Clough, Rachel E.
Spear, Rafaëlle
Mougin, Justine
Le Houérou, Thomas
Fabre, Dominique
Sobocinski, Jonathan
Haulon, Stéphan
author_facet Clough, Rachel E.
Spear, Rafaëlle
Mougin, Justine
Le Houérou, Thomas
Fabre, Dominique
Sobocinski, Jonathan
Haulon, Stéphan
author_sort Clough, Rachel E.
collection PubMed
description PURPOSE: Fenestrated endovascular aneurysm repair (fEVAR) is established for the treatment of juxtarenal, pararenal, and thoracoabdominal aortic aneurysms (TAAAs). Bridging stents are used to connect the main body of the stent graft to the aortic branch vessels. Complications related to the bridging stents compromise the durability of the repair and require urgent re-intervention. Here we present the midterm results of the BeGraft stent graft system used for fEVAR. MATERIALS AND METHOD: All consecutive patients treated with fEVAR and the current BeGraft Peripheral Stent Graft between November 2015 and September 2016 were included. RESULTS: Thirty-nine consecutive patients (38 men) were enrolled and 101 BeGraft second-generation stent grafts were implanted. The median aneurysm diameter was 60 mm (54.5–67.0 mm). Aneurysms were juxtarenal and pararenal (19/39, 48.1%), type 4 TAAA (3/39, 7.7%), type 1, 2, and 3 TAAA (7/39, 17.8%), type 5 TAAA (4/39, 10.2%), and 15.4% (6/39) had a type I endoleak following a previous EVAR. Fifty-five BeGrafts were implanted in mesenteric arteries (22 in coeliac trunks, 31 in the superior mesenteric artery, and 2 in a hepatic or splenic artery) and 46 into renal arteries (24 right and 22 left). The renal artery diameters were 5, 6, 7, and 8 mm in 9, 7, 26, and 4 patients, respectively. Mesenteric arteries were exclusively stented with 9 and 10 mm diameter devices. The median follow-up was 33 months (IQ25 17–IQ75 36). During follow-up, 11 patients died (28%) from non–aneurysm-related causes. The overall patency rates for bridging stents were 98% and 97% at 1 and 2 years, respectively, with a freedom from secondary procedure rate on BeGraft stent grafts of 96% (97/101). All events occurred on stents implanted in renal arteries. CONCLUSION: Early favorable outcomes are confirmed during longer term follow-up. Vigilant surveillance is required.
format Online
Article
Text
id pubmed-10350705
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-103507052023-07-18 Midterm Outcomes of BeGraft Stent Grafts Used as Bridging Stents in Fenestrated Endovascular Aortic Aneurysm Repair Clough, Rachel E. Spear, Rafaëlle Mougin, Justine Le Houérou, Thomas Fabre, Dominique Sobocinski, Jonathan Haulon, Stéphan J Endovasc Ther Clinical Investigations PURPOSE: Fenestrated endovascular aneurysm repair (fEVAR) is established for the treatment of juxtarenal, pararenal, and thoracoabdominal aortic aneurysms (TAAAs). Bridging stents are used to connect the main body of the stent graft to the aortic branch vessels. Complications related to the bridging stents compromise the durability of the repair and require urgent re-intervention. Here we present the midterm results of the BeGraft stent graft system used for fEVAR. MATERIALS AND METHOD: All consecutive patients treated with fEVAR and the current BeGraft Peripheral Stent Graft between November 2015 and September 2016 were included. RESULTS: Thirty-nine consecutive patients (38 men) were enrolled and 101 BeGraft second-generation stent grafts were implanted. The median aneurysm diameter was 60 mm (54.5–67.0 mm). Aneurysms were juxtarenal and pararenal (19/39, 48.1%), type 4 TAAA (3/39, 7.7%), type 1, 2, and 3 TAAA (7/39, 17.8%), type 5 TAAA (4/39, 10.2%), and 15.4% (6/39) had a type I endoleak following a previous EVAR. Fifty-five BeGrafts were implanted in mesenteric arteries (22 in coeliac trunks, 31 in the superior mesenteric artery, and 2 in a hepatic or splenic artery) and 46 into renal arteries (24 right and 22 left). The renal artery diameters were 5, 6, 7, and 8 mm in 9, 7, 26, and 4 patients, respectively. Mesenteric arteries were exclusively stented with 9 and 10 mm diameter devices. The median follow-up was 33 months (IQ25 17–IQ75 36). During follow-up, 11 patients died (28%) from non–aneurysm-related causes. The overall patency rates for bridging stents were 98% and 97% at 1 and 2 years, respectively, with a freedom from secondary procedure rate on BeGraft stent grafts of 96% (97/101). All events occurred on stents implanted in renal arteries. CONCLUSION: Early favorable outcomes are confirmed during longer term follow-up. Vigilant surveillance is required. SAGE Publications 2022-04-26 2023-08 /pmc/articles/PMC10350705/ /pubmed/35471131 http://dx.doi.org/10.1177/15266028221091894 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Clinical Investigations
Clough, Rachel E.
Spear, Rafaëlle
Mougin, Justine
Le Houérou, Thomas
Fabre, Dominique
Sobocinski, Jonathan
Haulon, Stéphan
Midterm Outcomes of BeGraft Stent Grafts Used as Bridging Stents in Fenestrated Endovascular Aortic Aneurysm Repair
title Midterm Outcomes of BeGraft Stent Grafts Used as Bridging Stents in Fenestrated Endovascular Aortic Aneurysm Repair
title_full Midterm Outcomes of BeGraft Stent Grafts Used as Bridging Stents in Fenestrated Endovascular Aortic Aneurysm Repair
title_fullStr Midterm Outcomes of BeGraft Stent Grafts Used as Bridging Stents in Fenestrated Endovascular Aortic Aneurysm Repair
title_full_unstemmed Midterm Outcomes of BeGraft Stent Grafts Used as Bridging Stents in Fenestrated Endovascular Aortic Aneurysm Repair
title_short Midterm Outcomes of BeGraft Stent Grafts Used as Bridging Stents in Fenestrated Endovascular Aortic Aneurysm Repair
title_sort midterm outcomes of begraft stent grafts used as bridging stents in fenestrated endovascular aortic aneurysm repair
topic Clinical Investigations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10350705/
https://www.ncbi.nlm.nih.gov/pubmed/35471131
http://dx.doi.org/10.1177/15266028221091894
work_keys_str_mv AT cloughrachele midtermoutcomesofbegraftstentgraftsusedasbridgingstentsinfenestratedendovascularaorticaneurysmrepair
AT spearrafaelle midtermoutcomesofbegraftstentgraftsusedasbridgingstentsinfenestratedendovascularaorticaneurysmrepair
AT mouginjustine midtermoutcomesofbegraftstentgraftsusedasbridgingstentsinfenestratedendovascularaorticaneurysmrepair
AT lehouerouthomas midtermoutcomesofbegraftstentgraftsusedasbridgingstentsinfenestratedendovascularaorticaneurysmrepair
AT fabredominique midtermoutcomesofbegraftstentgraftsusedasbridgingstentsinfenestratedendovascularaorticaneurysmrepair
AT sobocinskijonathan midtermoutcomesofbegraftstentgraftsusedasbridgingstentsinfenestratedendovascularaorticaneurysmrepair
AT haulonstephan midtermoutcomesofbegraftstentgraftsusedasbridgingstentsinfenestratedendovascularaorticaneurysmrepair