Cargando…

Evaluating the effect of setup uncertainty reduction and adaptation to geometric changes on normal tissue complication probability using online adaptive head and neck intensity modulated proton therapy

Objective. To evaluate the impact of setup uncertainty reduction (SUR) and adaptation to geometrical changes (AGC) on normal tissue complication probability (NTCP) when using online adaptive head and neck intensity modulated proton therapy (IMPT). Approach. A cohort of ten retrospective head and nec...

Descripción completa

Detalles Bibliográficos
Autores principales: Lalonde, Arthur, Bobić, Mislav, Sharp, Gregory C, Chamseddine, Ibrahim, Winey, Brian, Paganetti, Harald
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IOP Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10351361/
https://www.ncbi.nlm.nih.gov/pubmed/37164020
http://dx.doi.org/10.1088/1361-6560/acd433
_version_ 1785145935876063232
author Lalonde, Arthur
Bobić, Mislav
Sharp, Gregory C
Chamseddine, Ibrahim
Winey, Brian
Paganetti, Harald
author_facet Lalonde, Arthur
Bobić, Mislav
Sharp, Gregory C
Chamseddine, Ibrahim
Winey, Brian
Paganetti, Harald
author_sort Lalonde, Arthur
collection PubMed
description Objective. To evaluate the impact of setup uncertainty reduction (SUR) and adaptation to geometrical changes (AGC) on normal tissue complication probability (NTCP) when using online adaptive head and neck intensity modulated proton therapy (IMPT). Approach. A cohort of ten retrospective head and neck cancer patients with daily scatter corrected cone-beam CT (CBCT) was studied. For each patient, two IMPT treatment plans were created: one with a 3 mm setup uncertainty robustness setting and one with no explicit setup robustness. Both plans were recalculated on the daily CBCT considering three scenarios: the robust plan without adaptation, the non-robust plan without adaptation and the non-robust plan with daily online adaptation. Online-adaptation was simulated using an in-house developed workflow based on GPU-accelerated Monte Carlo dose calculation and partial spot-intensity re-optimization. Dose distributions associated with each scenario were accumulated on the planning CT, where NTCP models for six toxicities were applied. NTCP values from each scenario were intercompared to quantify the reduction in toxicity risk induced by SUR alone, AGC alone and SUR and AGC combined. Finally, a decision tree was implemented to assess the clinical significance of the toxicity reduction associated with each mechanism. Main results. For most patients, clinically meaningful NTCP reductions were only achieved when SUR and AGC were performed together. In these conditions, total reductions in NTCP of up to 30.48 pp were obtained, with noticeable NTCP reductions for aspiration, dysphagia and xerostomia (mean reductions of 8.25, 5.42 and 5.12 pp respectively). While SUR had a generally larger impact than AGC on NTCP reductions, SUR alone did not induce clinically meaningful toxicity reductions in any patient, compared to only one for AGC alone. Significance Online adaptive head and neck proton therapy can only yield clinically significant reductions in the risk of long-term side effects when combining the benefits of SUR and AGC.
format Online
Article
Text
id pubmed-10351361
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher IOP Publishing
record_format MEDLINE/PubMed
spelling pubmed-103513612023-12-05 Evaluating the effect of setup uncertainty reduction and adaptation to geometric changes on normal tissue complication probability using online adaptive head and neck intensity modulated proton therapy Lalonde, Arthur Bobić, Mislav Sharp, Gregory C Chamseddine, Ibrahim Winey, Brian Paganetti, Harald Phys Med Biol Paper Objective. To evaluate the impact of setup uncertainty reduction (SUR) and adaptation to geometrical changes (AGC) on normal tissue complication probability (NTCP) when using online adaptive head and neck intensity modulated proton therapy (IMPT). Approach. A cohort of ten retrospective head and neck cancer patients with daily scatter corrected cone-beam CT (CBCT) was studied. For each patient, two IMPT treatment plans were created: one with a 3 mm setup uncertainty robustness setting and one with no explicit setup robustness. Both plans were recalculated on the daily CBCT considering three scenarios: the robust plan without adaptation, the non-robust plan without adaptation and the non-robust plan with daily online adaptation. Online-adaptation was simulated using an in-house developed workflow based on GPU-accelerated Monte Carlo dose calculation and partial spot-intensity re-optimization. Dose distributions associated with each scenario were accumulated on the planning CT, where NTCP models for six toxicities were applied. NTCP values from each scenario were intercompared to quantify the reduction in toxicity risk induced by SUR alone, AGC alone and SUR and AGC combined. Finally, a decision tree was implemented to assess the clinical significance of the toxicity reduction associated with each mechanism. Main results. For most patients, clinically meaningful NTCP reductions were only achieved when SUR and AGC were performed together. In these conditions, total reductions in NTCP of up to 30.48 pp were obtained, with noticeable NTCP reductions for aspiration, dysphagia and xerostomia (mean reductions of 8.25, 5.42 and 5.12 pp respectively). While SUR had a generally larger impact than AGC on NTCP reductions, SUR alone did not induce clinically meaningful toxicity reductions in any patient, compared to only one for AGC alone. Significance Online adaptive head and neck proton therapy can only yield clinically significant reductions in the risk of long-term side effects when combining the benefits of SUR and AGC. IOP Publishing 2023-06-07 2023-05-30 /pmc/articles/PMC10351361/ /pubmed/37164020 http://dx.doi.org/10.1088/1361-6560/acd433 Text en © 2023 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd https://creativecommons.org/licenses/by/4.0/Original content from this work may be used under the terms of the Creative Commons Attribution 4.0 licence (https://creativecommons.org/licenses/by/4.0/) . Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.
spellingShingle Paper
Lalonde, Arthur
Bobić, Mislav
Sharp, Gregory C
Chamseddine, Ibrahim
Winey, Brian
Paganetti, Harald
Evaluating the effect of setup uncertainty reduction and adaptation to geometric changes on normal tissue complication probability using online adaptive head and neck intensity modulated proton therapy
title Evaluating the effect of setup uncertainty reduction and adaptation to geometric changes on normal tissue complication probability using online adaptive head and neck intensity modulated proton therapy
title_full Evaluating the effect of setup uncertainty reduction and adaptation to geometric changes on normal tissue complication probability using online adaptive head and neck intensity modulated proton therapy
title_fullStr Evaluating the effect of setup uncertainty reduction and adaptation to geometric changes on normal tissue complication probability using online adaptive head and neck intensity modulated proton therapy
title_full_unstemmed Evaluating the effect of setup uncertainty reduction and adaptation to geometric changes on normal tissue complication probability using online adaptive head and neck intensity modulated proton therapy
title_short Evaluating the effect of setup uncertainty reduction and adaptation to geometric changes on normal tissue complication probability using online adaptive head and neck intensity modulated proton therapy
title_sort evaluating the effect of setup uncertainty reduction and adaptation to geometric changes on normal tissue complication probability using online adaptive head and neck intensity modulated proton therapy
topic Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10351361/
https://www.ncbi.nlm.nih.gov/pubmed/37164020
http://dx.doi.org/10.1088/1361-6560/acd433
work_keys_str_mv AT lalondearthur evaluatingtheeffectofsetupuncertaintyreductionandadaptationtogeometricchangesonnormaltissuecomplicationprobabilityusingonlineadaptiveheadandneckintensitymodulatedprotontherapy
AT bobicmislav evaluatingtheeffectofsetupuncertaintyreductionandadaptationtogeometricchangesonnormaltissuecomplicationprobabilityusingonlineadaptiveheadandneckintensitymodulatedprotontherapy
AT sharpgregoryc evaluatingtheeffectofsetupuncertaintyreductionandadaptationtogeometricchangesonnormaltissuecomplicationprobabilityusingonlineadaptiveheadandneckintensitymodulatedprotontherapy
AT chamseddineibrahim evaluatingtheeffectofsetupuncertaintyreductionandadaptationtogeometricchangesonnormaltissuecomplicationprobabilityusingonlineadaptiveheadandneckintensitymodulatedprotontherapy
AT wineybrian evaluatingtheeffectofsetupuncertaintyreductionandadaptationtogeometricchangesonnormaltissuecomplicationprobabilityusingonlineadaptiveheadandneckintensitymodulatedprotontherapy
AT paganettiharald evaluatingtheeffectofsetupuncertaintyreductionandadaptationtogeometricchangesonnormaltissuecomplicationprobabilityusingonlineadaptiveheadandneckintensitymodulatedprotontherapy