Cargando…

The experience of device failure after cochlear implantation

BACKGROUND: The present study describes the treatment of patients at a tertiary institution who experienced device failure after Cochlear Implantation (CI), as well as identifying prodromic symptoms that could assist in the timely identification and management of device failure. STUDY DESIGN: Retros...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Jeong Heon, Choi, Yeonjoo, Kang, Woo Seok, Park, Hong Ju, Ahn, Joong Ho, Chung, Jong Woo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10353193/
https://www.ncbi.nlm.nih.gov/pubmed/37461054
http://dx.doi.org/10.1186/s40463-023-00652-7
_version_ 1785074667098210304
author Kim, Jeong Heon
Choi, Yeonjoo
Kang, Woo Seok
Park, Hong Ju
Ahn, Joong Ho
Chung, Jong Woo
author_facet Kim, Jeong Heon
Choi, Yeonjoo
Kang, Woo Seok
Park, Hong Ju
Ahn, Joong Ho
Chung, Jong Woo
author_sort Kim, Jeong Heon
collection PubMed
description BACKGROUND: The present study describes the treatment of patients at a tertiary institution who experienced device failure after Cochlear Implantation (CI), as well as identifying prodromic symptoms that could assist in the timely identification and management of device failure. STUDY DESIGN: Retrospective database review (January 2000–May 2017). SETTING: Single tertiary hospital. METHODS: Factors recorded included the etiology of hearing loss; age at first and revision CI surgeries; surgical information, including operation time and approach; electrical outcomes after implantation; device implanted; symptoms of device failure; history of head trauma; and audiologic outcomes as determined by categories of auditory performance (CAP). RESULTS: From January 2000 to May 2017, 1431 CIs were performed, with 27 (1.9%) undergoing revision surgeries due to device failure. The most common etiology of hearing loss was idiopathic (12/27), followed by cochlear hypoplasia (5/27). Mean age at initial CI was 11.8 (1–72) years, with 21 being pre-lingual and 6 being post-lingual. Of the total devices initially implanted, 80.5% were from Cochlear, 15.9% from MED-EL, and 3.5% from Advanced Bionics. The failure rates of these devices were 1.3%, 3.1%, and 10.0%, respectively. The most suggestive symptom of device failure was intermittent loss of signal. Mean CAP scores were 5.17 before reimplantation and 5.54 and 5.81 at 1- and 3-years, respectively, after reimplantation. CONCLUSION: The most suggestive symptom preceding device failure was intermittent loss of signal. Patients who present with this symptom should undergo electrical examination for suspected device failure. Audiologic outcomes showed continuous development despite revision surgeries.
format Online
Article
Text
id pubmed-10353193
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-103531932023-07-19 The experience of device failure after cochlear implantation Kim, Jeong Heon Choi, Yeonjoo Kang, Woo Seok Park, Hong Ju Ahn, Joong Ho Chung, Jong Woo J Otolaryngol Head Neck Surg Original Research Article BACKGROUND: The present study describes the treatment of patients at a tertiary institution who experienced device failure after Cochlear Implantation (CI), as well as identifying prodromic symptoms that could assist in the timely identification and management of device failure. STUDY DESIGN: Retrospective database review (January 2000–May 2017). SETTING: Single tertiary hospital. METHODS: Factors recorded included the etiology of hearing loss; age at first and revision CI surgeries; surgical information, including operation time and approach; electrical outcomes after implantation; device implanted; symptoms of device failure; history of head trauma; and audiologic outcomes as determined by categories of auditory performance (CAP). RESULTS: From January 2000 to May 2017, 1431 CIs were performed, with 27 (1.9%) undergoing revision surgeries due to device failure. The most common etiology of hearing loss was idiopathic (12/27), followed by cochlear hypoplasia (5/27). Mean age at initial CI was 11.8 (1–72) years, with 21 being pre-lingual and 6 being post-lingual. Of the total devices initially implanted, 80.5% were from Cochlear, 15.9% from MED-EL, and 3.5% from Advanced Bionics. The failure rates of these devices were 1.3%, 3.1%, and 10.0%, respectively. The most suggestive symptom of device failure was intermittent loss of signal. Mean CAP scores were 5.17 before reimplantation and 5.54 and 5.81 at 1- and 3-years, respectively, after reimplantation. CONCLUSION: The most suggestive symptom preceding device failure was intermittent loss of signal. Patients who present with this symptom should undergo electrical examination for suspected device failure. Audiologic outcomes showed continuous development despite revision surgeries. BioMed Central 2023-07-17 /pmc/articles/PMC10353193/ /pubmed/37461054 http://dx.doi.org/10.1186/s40463-023-00652-7 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Original Research Article
Kim, Jeong Heon
Choi, Yeonjoo
Kang, Woo Seok
Park, Hong Ju
Ahn, Joong Ho
Chung, Jong Woo
The experience of device failure after cochlear implantation
title The experience of device failure after cochlear implantation
title_full The experience of device failure after cochlear implantation
title_fullStr The experience of device failure after cochlear implantation
title_full_unstemmed The experience of device failure after cochlear implantation
title_short The experience of device failure after cochlear implantation
title_sort experience of device failure after cochlear implantation
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10353193/
https://www.ncbi.nlm.nih.gov/pubmed/37461054
http://dx.doi.org/10.1186/s40463-023-00652-7
work_keys_str_mv AT kimjeongheon theexperienceofdevicefailureaftercochlearimplantation
AT choiyeonjoo theexperienceofdevicefailureaftercochlearimplantation
AT kangwooseok theexperienceofdevicefailureaftercochlearimplantation
AT parkhongju theexperienceofdevicefailureaftercochlearimplantation
AT ahnjoongho theexperienceofdevicefailureaftercochlearimplantation
AT chungjongwoo theexperienceofdevicefailureaftercochlearimplantation
AT kimjeongheon experienceofdevicefailureaftercochlearimplantation
AT choiyeonjoo experienceofdevicefailureaftercochlearimplantation
AT kangwooseok experienceofdevicefailureaftercochlearimplantation
AT parkhongju experienceofdevicefailureaftercochlearimplantation
AT ahnjoongho experienceofdevicefailureaftercochlearimplantation
AT chungjongwoo experienceofdevicefailureaftercochlearimplantation