Pelvic radiation dose measurement for trauma patients in multifield radiographic examinations: A phantom‐based TLD dosimetry study

BACKGROUND AND AIMS: Trauma patients often suffer from multiple injuries and require undergoing various radiography which is referred to as multifield radiographic examinations. Protective measures may be ignored for these examinations due to stressful emergency situations or patients' conditio...

Descripción completa

Detalles Bibliográficos
Autores principales: Peiro, Ameneh, Chegeni, Nahid, Danyaei, Amir, Fatahiasl, Jafar, Tahmasbi, Marziyeh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10356977/
https://www.ncbi.nlm.nih.gov/pubmed/37484057
http://dx.doi.org/10.1002/hsr2.1424
_version_ 1785075395001843712
author Peiro, Ameneh
Chegeni, Nahid
Danyaei, Amir
Fatahiasl, Jafar
Tahmasbi, Marziyeh
author_facet Peiro, Ameneh
Chegeni, Nahid
Danyaei, Amir
Fatahiasl, Jafar
Tahmasbi, Marziyeh
author_sort Peiro, Ameneh
collection PubMed
description BACKGROUND AND AIMS: Trauma patients often suffer from multiple injuries and require undergoing various radiography which is referred to as multifield radiographic examinations. Protective measures may be ignored for these examinations due to stressful emergency situations or patients' conditions. This study was conducted to evaluate the scattered doses received by the pelvis during different common multifield radiographic examinations with an emphasis on field size adjustment. METHODS: A whole‐body phantom, PBU‐50, resembling the body mass, was used to carry out the common examinations for trauma patients (extremities, skull, chest, abdomen, pelvis, femur, and lumbar radiography), using a Pars Pad X‐ray machine. To measure the primary entrance skin doses, three calibrated GR 200 thermoluminescence dosimeter (TLD) chips were placed in the central X‐ray beam of scanned organs. Three TLDs were also placed on the pelvis symphysis pubis to measure the scattered dose received by the pelvis due to each carried‐out radiography for standard and clinically used field sizes. A Harshaw 3500 TLD Reader was used to read the chips. TLD readouts (nano‐Coulomb) were converted to dose (milli Gray [mGy]) using the predefined calibration curve. RESULTS: The scattered doses to the pelvis due to scanning a single organ differed from 0.80 to 1.70, and 0.82 to 4.09 mGy for standard and clinically used field sizes, respectively. The scattered doses to the pelvis in multifield examinations varied from 0.80 to 8.43 and 0.82 to 13.6 mGy for standard and clinically used field sizes, respectively, depending on the number of scanned organs and their distances from the pelvis. CONCLUSIONS: Multiple and repeated radiographs combined with insufficient protective measures can increase the patient's dose. The findings indicate that the scattered doses received by the pelvis can exceed the reference values in multifield radiography, especially if the radiation field is not restricted properly to the scanned organ.
format Online
Article
Text
id pubmed-10356977
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-103569772023-07-21 Pelvic radiation dose measurement for trauma patients in multifield radiographic examinations: A phantom‐based TLD dosimetry study Peiro, Ameneh Chegeni, Nahid Danyaei, Amir Fatahiasl, Jafar Tahmasbi, Marziyeh Health Sci Rep Original Research BACKGROUND AND AIMS: Trauma patients often suffer from multiple injuries and require undergoing various radiography which is referred to as multifield radiographic examinations. Protective measures may be ignored for these examinations due to stressful emergency situations or patients' conditions. This study was conducted to evaluate the scattered doses received by the pelvis during different common multifield radiographic examinations with an emphasis on field size adjustment. METHODS: A whole‐body phantom, PBU‐50, resembling the body mass, was used to carry out the common examinations for trauma patients (extremities, skull, chest, abdomen, pelvis, femur, and lumbar radiography), using a Pars Pad X‐ray machine. To measure the primary entrance skin doses, three calibrated GR 200 thermoluminescence dosimeter (TLD) chips were placed in the central X‐ray beam of scanned organs. Three TLDs were also placed on the pelvis symphysis pubis to measure the scattered dose received by the pelvis due to each carried‐out radiography for standard and clinically used field sizes. A Harshaw 3500 TLD Reader was used to read the chips. TLD readouts (nano‐Coulomb) were converted to dose (milli Gray [mGy]) using the predefined calibration curve. RESULTS: The scattered doses to the pelvis due to scanning a single organ differed from 0.80 to 1.70, and 0.82 to 4.09 mGy for standard and clinically used field sizes, respectively. The scattered doses to the pelvis in multifield examinations varied from 0.80 to 8.43 and 0.82 to 13.6 mGy for standard and clinically used field sizes, respectively, depending on the number of scanned organs and their distances from the pelvis. CONCLUSIONS: Multiple and repeated radiographs combined with insufficient protective measures can increase the patient's dose. The findings indicate that the scattered doses received by the pelvis can exceed the reference values in multifield radiography, especially if the radiation field is not restricted properly to the scanned organ. John Wiley and Sons Inc. 2023-07-19 /pmc/articles/PMC10356977/ /pubmed/37484057 http://dx.doi.org/10.1002/hsr2.1424 Text en © 2023 The Authors. Health Science Reports published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Research
Peiro, Ameneh
Chegeni, Nahid
Danyaei, Amir
Fatahiasl, Jafar
Tahmasbi, Marziyeh
Pelvic radiation dose measurement for trauma patients in multifield radiographic examinations: A phantom‐based TLD dosimetry study
title Pelvic radiation dose measurement for trauma patients in multifield radiographic examinations: A phantom‐based TLD dosimetry study
title_full Pelvic radiation dose measurement for trauma patients in multifield radiographic examinations: A phantom‐based TLD dosimetry study
title_fullStr Pelvic radiation dose measurement for trauma patients in multifield radiographic examinations: A phantom‐based TLD dosimetry study
title_full_unstemmed Pelvic radiation dose measurement for trauma patients in multifield radiographic examinations: A phantom‐based TLD dosimetry study
title_short Pelvic radiation dose measurement for trauma patients in multifield radiographic examinations: A phantom‐based TLD dosimetry study
title_sort pelvic radiation dose measurement for trauma patients in multifield radiographic examinations: a phantom‐based tld dosimetry study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10356977/
https://www.ncbi.nlm.nih.gov/pubmed/37484057
http://dx.doi.org/10.1002/hsr2.1424
work_keys_str_mv AT peiroameneh pelvicradiationdosemeasurementfortraumapatientsinmultifieldradiographicexaminationsaphantombasedtlddosimetrystudy
AT chegeninahid pelvicradiationdosemeasurementfortraumapatientsinmultifieldradiographicexaminationsaphantombasedtlddosimetrystudy
AT danyaeiamir pelvicradiationdosemeasurementfortraumapatientsinmultifieldradiographicexaminationsaphantombasedtlddosimetrystudy
AT fatahiasljafar pelvicradiationdosemeasurementfortraumapatientsinmultifieldradiographicexaminationsaphantombasedtlddosimetrystudy
AT tahmasbimarziyeh pelvicradiationdosemeasurementfortraumapatientsinmultifieldradiographicexaminationsaphantombasedtlddosimetrystudy