Cargando…

Use of Ocular Response Analyzer Output Data in the Management of Low Intraocular Pressure after Glaucoma Filtration Surgery

AIM: To highlight potential benefits of using Reichert's ocular response analyzer (ORA) for intraocular pressure (IOP) measurement following glaucoma filtering surgery (GFS), especially in cases of low IOP. BACKGROUND: Goldmann applanation tonometry (GAT) is widely regarded as the gold standard...

Descripción completa

Detalles Bibliográficos
Autores principales: Dawson, Sarah, Mohite, Abhijit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Jaypee Brothers Medical Publishers 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10357027/
https://www.ncbi.nlm.nih.gov/pubmed/37485464
http://dx.doi.org/10.5005/jp-journals-10078-1402
_version_ 1785075405524303872
author Dawson, Sarah
Mohite, Abhijit
author_facet Dawson, Sarah
Mohite, Abhijit
author_sort Dawson, Sarah
collection PubMed
description AIM: To highlight potential benefits of using Reichert's ocular response analyzer (ORA) for intraocular pressure (IOP) measurement following glaucoma filtering surgery (GFS), especially in cases of low IOP. BACKGROUND: Goldmann applanation tonometry (GAT) is widely regarded as the gold standard of IOP measurement in clinical practice. The ORA also calculates corneal biomechanics, which is used in the calculation of the cornea-compensated IOP (IOPcc).(1) This useful, previously unknown information can be used to guide management in challenging clinical cases. CASE DESCRIPTION: A 78-year-old lady underwent right trabeculectomy with mitomycin C. During the first 9 months postoperatively, IOP's when measured with GAT, were found to be low (ranging between 2 mm Hg and 5 mm Hg). The patient displayed no clinical features of hypotony and visual acuity remained stable throughout. IOP was also measured with Reichert's ORA, which gives readings for corneal hysteresis (CH), corneal resistance factor and corneal corrected IOP. IOPcc measurements obtained with ORA were consistently higher, ranging from 6.7 mm Hg to 9.3 mm Hg and were more in keeping with the clinical features of the case. CONCLUSION: This case highlights the possibility that GAT can underestimate the true IOP in eyes with low IOP following GFS, as it does not account for corneal biomechanical properties. CLINICAL SIGNIFICANCE: Ocular response analyzer (ORA)—measured IOPcc may be a useful adjunct in reassuring surgeons to manage postoperative numerical hypotony conservatively in the absence of any clinical signs of hypotony. HOW TO CITE THIS ARTICLE: Dawson S, Mohite A. Use of Ocular Response Analyzer Output Data in the Management of Low Intraocular Pressure after Glaucoma Filtration Surgery. J Curr Glaucoma Pract 2023;17(2):104-105.
format Online
Article
Text
id pubmed-10357027
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Jaypee Brothers Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-103570272023-07-21 Use of Ocular Response Analyzer Output Data in the Management of Low Intraocular Pressure after Glaucoma Filtration Surgery Dawson, Sarah Mohite, Abhijit J Curr Glaucoma Pract Case Report AIM: To highlight potential benefits of using Reichert's ocular response analyzer (ORA) for intraocular pressure (IOP) measurement following glaucoma filtering surgery (GFS), especially in cases of low IOP. BACKGROUND: Goldmann applanation tonometry (GAT) is widely regarded as the gold standard of IOP measurement in clinical practice. The ORA also calculates corneal biomechanics, which is used in the calculation of the cornea-compensated IOP (IOPcc).(1) This useful, previously unknown information can be used to guide management in challenging clinical cases. CASE DESCRIPTION: A 78-year-old lady underwent right trabeculectomy with mitomycin C. During the first 9 months postoperatively, IOP's when measured with GAT, were found to be low (ranging between 2 mm Hg and 5 mm Hg). The patient displayed no clinical features of hypotony and visual acuity remained stable throughout. IOP was also measured with Reichert's ORA, which gives readings for corneal hysteresis (CH), corneal resistance factor and corneal corrected IOP. IOPcc measurements obtained with ORA were consistently higher, ranging from 6.7 mm Hg to 9.3 mm Hg and were more in keeping with the clinical features of the case. CONCLUSION: This case highlights the possibility that GAT can underestimate the true IOP in eyes with low IOP following GFS, as it does not account for corneal biomechanical properties. CLINICAL SIGNIFICANCE: Ocular response analyzer (ORA)—measured IOPcc may be a useful adjunct in reassuring surgeons to manage postoperative numerical hypotony conservatively in the absence of any clinical signs of hypotony. HOW TO CITE THIS ARTICLE: Dawson S, Mohite A. Use of Ocular Response Analyzer Output Data in the Management of Low Intraocular Pressure after Glaucoma Filtration Surgery. J Curr Glaucoma Pract 2023;17(2):104-105. Jaypee Brothers Medical Publishers 2023 /pmc/articles/PMC10357027/ /pubmed/37485464 http://dx.doi.org/10.5005/jp-journals-10078-1402 Text en Copyright © 2023; The Author(s). https://creativecommons.org/licenses/by-nc/4.0/© The Author(s). 2023 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated.
spellingShingle Case Report
Dawson, Sarah
Mohite, Abhijit
Use of Ocular Response Analyzer Output Data in the Management of Low Intraocular Pressure after Glaucoma Filtration Surgery
title Use of Ocular Response Analyzer Output Data in the Management of Low Intraocular Pressure after Glaucoma Filtration Surgery
title_full Use of Ocular Response Analyzer Output Data in the Management of Low Intraocular Pressure after Glaucoma Filtration Surgery
title_fullStr Use of Ocular Response Analyzer Output Data in the Management of Low Intraocular Pressure after Glaucoma Filtration Surgery
title_full_unstemmed Use of Ocular Response Analyzer Output Data in the Management of Low Intraocular Pressure after Glaucoma Filtration Surgery
title_short Use of Ocular Response Analyzer Output Data in the Management of Low Intraocular Pressure after Glaucoma Filtration Surgery
title_sort use of ocular response analyzer output data in the management of low intraocular pressure after glaucoma filtration surgery
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10357027/
https://www.ncbi.nlm.nih.gov/pubmed/37485464
http://dx.doi.org/10.5005/jp-journals-10078-1402
work_keys_str_mv AT dawsonsarah useofocularresponseanalyzeroutputdatainthemanagementoflowintraocularpressureafterglaucomafiltrationsurgery
AT mohiteabhijit useofocularresponseanalyzeroutputdatainthemanagementoflowintraocularpressureafterglaucomafiltrationsurgery