Cargando…
Comparative study of K-wire combined with screw vs. K-wire in the treatment of AO type B3.1 phalangeal fractures
PURPOSE: The purpose of this study was to introduce the surgical method of K-wire combined with screw in the treatment of Arbeitsgemeinschaftfür Osteosynthesefragen (AO) type B3.1 phalangeal fractures and to compare its clinical, radiological and functional outcomes with K-wire fixation. METHODS: Th...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10357621/ https://www.ncbi.nlm.nih.gov/pubmed/37468856 http://dx.doi.org/10.1186/s12891-023-06731-0 |
_version_ | 1785075532135661568 |
---|---|
author | Ma, Xuelin Wang, Li Zhang, Xiaoran Zhang, Zhemin Xu, Yali Lv, Li Shao, Xinzhong |
author_facet | Ma, Xuelin Wang, Li Zhang, Xiaoran Zhang, Zhemin Xu, Yali Lv, Li Shao, Xinzhong |
author_sort | Ma, Xuelin |
collection | PubMed |
description | PURPOSE: The purpose of this study was to introduce the surgical method of K-wire combined with screw in the treatment of Arbeitsgemeinschaftfür Osteosynthesefragen (AO) type B3.1 phalangeal fractures and to compare its clinical, radiological and functional outcomes with K-wire fixation. METHODS: This was a retrospective comparative study. From January 2015 to February 2022, we treated 86 patients with AO type B3.1 phalangeal fractures. A total of 71 patients were finally included in the statistical analysis. Thirty-nine patients received K-wires combined with screw, and 32 patients received simple K-wires. The follow-up time was at least 6 months. Outcome measures included general information, operative time, total active motion (TAM), pinch strength, radiological union time, pain assessed by visual analog scale (VAS), Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH) score, cost, and complications. RESULTS: The follow-up time was 6–12 months, with an average of 7.9 months. All patients achieved clinical and radiological union. Compared with the K-wire fixation group, the TAM, radiological union time and VAS score of the K-wire combined with screw group had obvious advantages. Compared with the opposite healthy hand, the grip strength of the two groups was similar, and there was no significant difference in the QuickDASH score. The incidence rate of complications in the K-wire combined with screw group (2/39) was lower than that in the K-wire fixation group (7/32). CONCLUSIONS: Compared with simple K-wire fixation, K-wire combined with screw in the treatment of AO type B3.1 phalangeal fractures is a safer and reliable surgical method. K-wire controls the rotation and plays a role similar to a “lock”. The screw can exert pressure and fix it more firmly. It shortens the time of fracture healing and has a higher TAM and fewer postoperative complications. |
format | Online Article Text |
id | pubmed-10357621 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-103576212023-07-21 Comparative study of K-wire combined with screw vs. K-wire in the treatment of AO type B3.1 phalangeal fractures Ma, Xuelin Wang, Li Zhang, Xiaoran Zhang, Zhemin Xu, Yali Lv, Li Shao, Xinzhong BMC Musculoskelet Disord Research PURPOSE: The purpose of this study was to introduce the surgical method of K-wire combined with screw in the treatment of Arbeitsgemeinschaftfür Osteosynthesefragen (AO) type B3.1 phalangeal fractures and to compare its clinical, radiological and functional outcomes with K-wire fixation. METHODS: This was a retrospective comparative study. From January 2015 to February 2022, we treated 86 patients with AO type B3.1 phalangeal fractures. A total of 71 patients were finally included in the statistical analysis. Thirty-nine patients received K-wires combined with screw, and 32 patients received simple K-wires. The follow-up time was at least 6 months. Outcome measures included general information, operative time, total active motion (TAM), pinch strength, radiological union time, pain assessed by visual analog scale (VAS), Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH) score, cost, and complications. RESULTS: The follow-up time was 6–12 months, with an average of 7.9 months. All patients achieved clinical and radiological union. Compared with the K-wire fixation group, the TAM, radiological union time and VAS score of the K-wire combined with screw group had obvious advantages. Compared with the opposite healthy hand, the grip strength of the two groups was similar, and there was no significant difference in the QuickDASH score. The incidence rate of complications in the K-wire combined with screw group (2/39) was lower than that in the K-wire fixation group (7/32). CONCLUSIONS: Compared with simple K-wire fixation, K-wire combined with screw in the treatment of AO type B3.1 phalangeal fractures is a safer and reliable surgical method. K-wire controls the rotation and plays a role similar to a “lock”. The screw can exert pressure and fix it more firmly. It shortens the time of fracture healing and has a higher TAM and fewer postoperative complications. BioMed Central 2023-07-19 /pmc/articles/PMC10357621/ /pubmed/37468856 http://dx.doi.org/10.1186/s12891-023-06731-0 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Ma, Xuelin Wang, Li Zhang, Xiaoran Zhang, Zhemin Xu, Yali Lv, Li Shao, Xinzhong Comparative study of K-wire combined with screw vs. K-wire in the treatment of AO type B3.1 phalangeal fractures |
title | Comparative study of K-wire combined with screw vs. K-wire in the treatment of AO type B3.1 phalangeal fractures |
title_full | Comparative study of K-wire combined with screw vs. K-wire in the treatment of AO type B3.1 phalangeal fractures |
title_fullStr | Comparative study of K-wire combined with screw vs. K-wire in the treatment of AO type B3.1 phalangeal fractures |
title_full_unstemmed | Comparative study of K-wire combined with screw vs. K-wire in the treatment of AO type B3.1 phalangeal fractures |
title_short | Comparative study of K-wire combined with screw vs. K-wire in the treatment of AO type B3.1 phalangeal fractures |
title_sort | comparative study of k-wire combined with screw vs. k-wire in the treatment of ao type b3.1 phalangeal fractures |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10357621/ https://www.ncbi.nlm.nih.gov/pubmed/37468856 http://dx.doi.org/10.1186/s12891-023-06731-0 |
work_keys_str_mv | AT maxuelin comparativestudyofkwirecombinedwithscrewvskwireinthetreatmentofaotypeb31phalangealfractures AT wangli comparativestudyofkwirecombinedwithscrewvskwireinthetreatmentofaotypeb31phalangealfractures AT zhangxiaoran comparativestudyofkwirecombinedwithscrewvskwireinthetreatmentofaotypeb31phalangealfractures AT zhangzhemin comparativestudyofkwirecombinedwithscrewvskwireinthetreatmentofaotypeb31phalangealfractures AT xuyali comparativestudyofkwirecombinedwithscrewvskwireinthetreatmentofaotypeb31phalangealfractures AT lvli comparativestudyofkwirecombinedwithscrewvskwireinthetreatmentofaotypeb31phalangealfractures AT shaoxinzhong comparativestudyofkwirecombinedwithscrewvskwireinthetreatmentofaotypeb31phalangealfractures |