Cargando…
Effective prevention of post-dural puncture headache with insertion of an intrathecal catheter in parturients: a retrospective study and meta-analysis
BACKGROUND: Accidental dural puncture is a common complication of labour analgesia. It can trigger post-dural puncture headache, with associated morbidity and increased costs. Intrathecal catheter placement is a prophylactic procedure which can reduce incidence and severity of post-dural puncture he...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10357735/ https://www.ncbi.nlm.nih.gov/pubmed/37475027 http://dx.doi.org/10.1186/s44158-023-00107-5 |
Sumario: | BACKGROUND: Accidental dural puncture is a common complication of labour analgesia. It can trigger post-dural puncture headache, with associated morbidity and increased costs. Intrathecal catheter placement is a prophylactic procedure which can reduce incidence and severity of post-dural puncture headache. METHODS: We conducted a retrospective single-centred study to define incidence and risk factors of accidental dural puncture and post-dural puncture headache in an obstetric population. We also evaluated effectiveness of intrathecal catheter placement compared to epidural catheter replacement in reducing incidence of post-dural puncture headache. We then conducted a systematic review and meta-analysis which included all studies comparing intrathecal catheter placement to epidural catheter replacement in obstetric patients with accidental dural puncture assessing the outcome of reduced incidence of post-dural puncture headache as a dichotomous variable. RESULTS: Accidental dural puncture had an incidence of 0.25% (60 cases). Of these, 66% developed post-dural puncture headache. A total of 77% (47/60) of patients with accidental dural puncture were treated with an intrathecal catheter placement, while 23% (13/60) had an epidural catheter replacement. Incidence of post-dural puncture headache was lower in the intrathecal catheter group (spinal 26/47, 60.5% epidural 11/13, 84.6%), although not reaching statistical significance (RR 0.71, CI 95%: 0.51–1.00; p = 0.049). The meta-analysis revealed that intrathecal catheter placement significantly reduced incidence of post-dural puncture headache compared to epidural catheter replacement (pooled RR 0.81, 95% CI 0.72–0.91, p < 0.001). CONCLUSIONS: Intrathecal catheter placement is a promising measure to prevent post-dural puncture headache, especially if followed by a pain management protocol and a continuous saline infusion. |
---|