Cargando…

Sensitive ratiometric sensor for Al(III) detection in water samples using luminescence or eye-vision

A facile, quick, and sensitive ratiometric luminescence sensor is designed for detection aluminum ions in water samples using luminescence or eye-vision. This approach relies on the emission change of the europium(III) complex with 3-(2-naphthoyl)-1,1,1,-trifluoro acetone (3-NTA) after interaction w...

Descripción completa

Detalles Bibliográficos
Autores principales: Khairy, Gasser M., Amin, Alaa S., Moalla, Sayed M. N., Medhat, Ayman, Hassan, Nader
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Nature Singapore 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10359221/
https://www.ncbi.nlm.nih.gov/pubmed/37071307
http://dx.doi.org/10.1007/s44211-023-00340-6
_version_ 1785075831809245184
author Khairy, Gasser M.
Amin, Alaa S.
Moalla, Sayed M. N.
Medhat, Ayman
Hassan, Nader
author_facet Khairy, Gasser M.
Amin, Alaa S.
Moalla, Sayed M. N.
Medhat, Ayman
Hassan, Nader
author_sort Khairy, Gasser M.
collection PubMed
description A facile, quick, and sensitive ratiometric luminescence sensor is designed for detection aluminum ions in water samples using luminescence or eye-vision. This approach relies on the emission change of the europium(III) complex with 3-(2-naphthoyl)-1,1,1,-trifluoro acetone (3-NTA) after interaction with various concentration of aluminum ions. The addition of aluminum ions suppressed the Eu(III) emission at 615 nm under 333 nm excitation, while simultaneously enhancing the ligand emission at 480 nm. Optimum detection was obtained in methanol. The quantification of aluminum ions using ratiometric method was determined by plotting the luminescence ratio (F(480nm)/F(615nm)) versus aluminum ions concentration. The calibration plot was obtained within the range 0.1–100 µM with LOD = 0.27 µM. Additionally, the concentration of aluminum ions can be estimated semi-quantitatively by visually observing the luminescence colour change of the probe from red to light green and then to dark green after being excited by a UV lamp with 365 nm. As far as we are aware, this is the first luminescent lanthanide complex-based ratiometric probe for the detection of aluminum ions. The probe showed remarkable aluminum ions selectivity relative to that of other metal ions. The suggested sensor was used effectively to identify aluminum ions in water samples with good results. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s44211-023-00340-6.
format Online
Article
Text
id pubmed-10359221
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Nature Singapore
record_format MEDLINE/PubMed
spelling pubmed-103592212023-07-22 Sensitive ratiometric sensor for Al(III) detection in water samples using luminescence or eye-vision Khairy, Gasser M. Amin, Alaa S. Moalla, Sayed M. N. Medhat, Ayman Hassan, Nader Anal Sci Original Paper A facile, quick, and sensitive ratiometric luminescence sensor is designed for detection aluminum ions in water samples using luminescence or eye-vision. This approach relies on the emission change of the europium(III) complex with 3-(2-naphthoyl)-1,1,1,-trifluoro acetone (3-NTA) after interaction with various concentration of aluminum ions. The addition of aluminum ions suppressed the Eu(III) emission at 615 nm under 333 nm excitation, while simultaneously enhancing the ligand emission at 480 nm. Optimum detection was obtained in methanol. The quantification of aluminum ions using ratiometric method was determined by plotting the luminescence ratio (F(480nm)/F(615nm)) versus aluminum ions concentration. The calibration plot was obtained within the range 0.1–100 µM with LOD = 0.27 µM. Additionally, the concentration of aluminum ions can be estimated semi-quantitatively by visually observing the luminescence colour change of the probe from red to light green and then to dark green after being excited by a UV lamp with 365 nm. As far as we are aware, this is the first luminescent lanthanide complex-based ratiometric probe for the detection of aluminum ions. The probe showed remarkable aluminum ions selectivity relative to that of other metal ions. The suggested sensor was used effectively to identify aluminum ions in water samples with good results. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s44211-023-00340-6. Springer Nature Singapore 2023-04-18 2023 /pmc/articles/PMC10359221/ /pubmed/37071307 http://dx.doi.org/10.1007/s44211-023-00340-6 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Paper
Khairy, Gasser M.
Amin, Alaa S.
Moalla, Sayed M. N.
Medhat, Ayman
Hassan, Nader
Sensitive ratiometric sensor for Al(III) detection in water samples using luminescence or eye-vision
title Sensitive ratiometric sensor for Al(III) detection in water samples using luminescence or eye-vision
title_full Sensitive ratiometric sensor for Al(III) detection in water samples using luminescence or eye-vision
title_fullStr Sensitive ratiometric sensor for Al(III) detection in water samples using luminescence or eye-vision
title_full_unstemmed Sensitive ratiometric sensor for Al(III) detection in water samples using luminescence or eye-vision
title_short Sensitive ratiometric sensor for Al(III) detection in water samples using luminescence or eye-vision
title_sort sensitive ratiometric sensor for al(iii) detection in water samples using luminescence or eye-vision
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10359221/
https://www.ncbi.nlm.nih.gov/pubmed/37071307
http://dx.doi.org/10.1007/s44211-023-00340-6
work_keys_str_mv AT khairygasserm sensitiveratiometricsensorforaliiidetectioninwatersamplesusingluminescenceoreyevision
AT aminalaas sensitiveratiometricsensorforaliiidetectioninwatersamplesusingluminescenceoreyevision
AT moallasayedmn sensitiveratiometricsensorforaliiidetectioninwatersamplesusingluminescenceoreyevision
AT medhatayman sensitiveratiometricsensorforaliiidetectioninwatersamplesusingluminescenceoreyevision
AT hassannader sensitiveratiometricsensorforaliiidetectioninwatersamplesusingluminescenceoreyevision