Cargando…
Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study
PURPOSE: To examine the normative profile of retinal nerve fibre layer (RNFL) thickness and ocular parameters based on spectral-domain optical coherence tomography (SD-OCT) and its associations with related parameters among the Chinese population. METHODS: This population-based cohort Handan Eye Stu...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10359552/ https://www.ncbi.nlm.nih.gov/pubmed/35383049 http://dx.doi.org/10.1136/bjophthalmol-2021-320618 |
_version_ | 1785075908933058560 |
---|---|
author | Wu, Jian Du, Yifan Lin, Caixia Zhu, Yingting Chen, Wei Pan, Qing Zhuo, Yehong Wang, Ningli |
author_facet | Wu, Jian Du, Yifan Lin, Caixia Zhu, Yingting Chen, Wei Pan, Qing Zhuo, Yehong Wang, Ningli |
author_sort | Wu, Jian |
collection | PubMed |
description | PURPOSE: To examine the normative profile of retinal nerve fibre layer (RNFL) thickness and ocular parameters based on spectral-domain optical coherence tomography (SD-OCT) and its associations with related parameters among the Chinese population. METHODS: This population-based cohort Handan Eye Study (HES) recruited participants aged≥30 years. All subjects underwent a standardised ophthalmic examination. Peripapillary RNFL thickness was obtained using SD-OCT. Mixed linear models were adopted to evaluate the correlation of RNFL thickness with ocular parameters as well as systemic factors. R V.3.6.1 software was used for statistical analysis. RESULTS: 3509 subjects (7024 eyes) with the average age of 55.54±10.37 were collected in this analysis. Overall mean RNFL thickness measured was 113.46±10.90 µm, and the thickest quadrant of parapapillary RNFL was the inferior quadrant, followed by the superior quadrant, the nasal quadrant and the temporal quadrant. In the multivariate linear regression model, thinner RNFL thickness was remarkable association with male (p<0.001), older age (p<0.001), increased body mass index (>30, p=0.018), absence of diabetes (p=0.009), history of cataract surgery (p=0.001), higher intraocular pressure (p=0.007), lower spherical equivalent (p<0.001) and increased axial length (p=0.048). CONCLUSIONS: In non-glaucoma individuals, this difference of RNFL thickness in Chinese population should be noted in making disease diagnoses. Meanwhile, multiple ocular and systemic factors are closely related to the thickness of RNFL. Our findings further emphasise the need to demonstrate ethnic differences in RNFL thickness and the specificity of associated ocular and systemic factors, as well as to develop better normative databases worldwide. TRIAL REGISTRATION NUMBER: HES was registered in Chinese Clinical Trial Registry website, and the registry number was ChiCTR-EOC-17013214. |
format | Online Article Text |
id | pubmed-10359552 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-103595522023-07-22 Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study Wu, Jian Du, Yifan Lin, Caixia Zhu, Yingting Chen, Wei Pan, Qing Zhuo, Yehong Wang, Ningli Br J Ophthalmol Clinical Science PURPOSE: To examine the normative profile of retinal nerve fibre layer (RNFL) thickness and ocular parameters based on spectral-domain optical coherence tomography (SD-OCT) and its associations with related parameters among the Chinese population. METHODS: This population-based cohort Handan Eye Study (HES) recruited participants aged≥30 years. All subjects underwent a standardised ophthalmic examination. Peripapillary RNFL thickness was obtained using SD-OCT. Mixed linear models were adopted to evaluate the correlation of RNFL thickness with ocular parameters as well as systemic factors. R V.3.6.1 software was used for statistical analysis. RESULTS: 3509 subjects (7024 eyes) with the average age of 55.54±10.37 were collected in this analysis. Overall mean RNFL thickness measured was 113.46±10.90 µm, and the thickest quadrant of parapapillary RNFL was the inferior quadrant, followed by the superior quadrant, the nasal quadrant and the temporal quadrant. In the multivariate linear regression model, thinner RNFL thickness was remarkable association with male (p<0.001), older age (p<0.001), increased body mass index (>30, p=0.018), absence of diabetes (p=0.009), history of cataract surgery (p=0.001), higher intraocular pressure (p=0.007), lower spherical equivalent (p<0.001) and increased axial length (p=0.048). CONCLUSIONS: In non-glaucoma individuals, this difference of RNFL thickness in Chinese population should be noted in making disease diagnoses. Meanwhile, multiple ocular and systemic factors are closely related to the thickness of RNFL. Our findings further emphasise the need to demonstrate ethnic differences in RNFL thickness and the specificity of associated ocular and systemic factors, as well as to develop better normative databases worldwide. TRIAL REGISTRATION NUMBER: HES was registered in Chinese Clinical Trial Registry website, and the registry number was ChiCTR-EOC-17013214. BMJ Publishing Group 2023-08 2022-04-05 /pmc/articles/PMC10359552/ /pubmed/35383049 http://dx.doi.org/10.1136/bjophthalmol-2021-320618 Text en © Author(s) (or their employer(s)) 2023. Re-use permitted under CC BY. Published by BMJ. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution 4.0 Unported (CC BY 4.0) license, which permits others to copy, redistribute, remix, transform and build upon this work for any purpose, provided the original work is properly cited, a link to the licence is given, and indication of whether changes were made. See: https://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Clinical Science Wu, Jian Du, Yifan Lin, Caixia Zhu, Yingting Chen, Wei Pan, Qing Zhuo, Yehong Wang, Ningli Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study |
title | Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study |
title_full | Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study |
title_fullStr | Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study |
title_full_unstemmed | Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study |
title_short | Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study |
title_sort | retinal nerve fibre layer thickness measured with sd-oct in a population-based study: the handan eye study |
topic | Clinical Science |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10359552/ https://www.ncbi.nlm.nih.gov/pubmed/35383049 http://dx.doi.org/10.1136/bjophthalmol-2021-320618 |
work_keys_str_mv | AT wujian retinalnervefibrelayerthicknessmeasuredwithsdoctinapopulationbasedstudythehandaneyestudy AT duyifan retinalnervefibrelayerthicknessmeasuredwithsdoctinapopulationbasedstudythehandaneyestudy AT lincaixia retinalnervefibrelayerthicknessmeasuredwithsdoctinapopulationbasedstudythehandaneyestudy AT zhuyingting retinalnervefibrelayerthicknessmeasuredwithsdoctinapopulationbasedstudythehandaneyestudy AT chenwei retinalnervefibrelayerthicknessmeasuredwithsdoctinapopulationbasedstudythehandaneyestudy AT panqing retinalnervefibrelayerthicknessmeasuredwithsdoctinapopulationbasedstudythehandaneyestudy AT zhuoyehong retinalnervefibrelayerthicknessmeasuredwithsdoctinapopulationbasedstudythehandaneyestudy AT wangningli retinalnervefibrelayerthicknessmeasuredwithsdoctinapopulationbasedstudythehandaneyestudy |