Cargando…

Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study

PURPOSE: To examine the normative profile of retinal nerve fibre layer (RNFL) thickness and ocular parameters based on spectral-domain optical coherence tomography (SD-OCT) and its associations with related parameters among the Chinese population. METHODS: This population-based cohort Handan Eye Stu...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Jian, Du, Yifan, Lin, Caixia, Zhu, Yingting, Chen, Wei, Pan, Qing, Zhuo, Yehong, Wang, Ningli
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10359552/
https://www.ncbi.nlm.nih.gov/pubmed/35383049
http://dx.doi.org/10.1136/bjophthalmol-2021-320618
_version_ 1785075908933058560
author Wu, Jian
Du, Yifan
Lin, Caixia
Zhu, Yingting
Chen, Wei
Pan, Qing
Zhuo, Yehong
Wang, Ningli
author_facet Wu, Jian
Du, Yifan
Lin, Caixia
Zhu, Yingting
Chen, Wei
Pan, Qing
Zhuo, Yehong
Wang, Ningli
author_sort Wu, Jian
collection PubMed
description PURPOSE: To examine the normative profile of retinal nerve fibre layer (RNFL) thickness and ocular parameters based on spectral-domain optical coherence tomography (SD-OCT) and its associations with related parameters among the Chinese population. METHODS: This population-based cohort Handan Eye Study (HES) recruited participants aged≥30 years. All subjects underwent a standardised ophthalmic examination. Peripapillary RNFL thickness was obtained using SD-OCT. Mixed linear models were adopted to evaluate the correlation of RNFL thickness with ocular parameters as well as systemic factors. R V.3.6.1 software was used for statistical analysis. RESULTS: 3509 subjects (7024 eyes) with the average age of 55.54±10.37 were collected in this analysis. Overall mean RNFL thickness measured was 113.46±10.90 µm, and the thickest quadrant of parapapillary RNFL was the inferior quadrant, followed by the superior quadrant, the nasal quadrant and the temporal quadrant. In the multivariate linear regression model, thinner RNFL thickness was remarkable association with male (p<0.001), older age (p<0.001), increased body mass index (>30, p=0.018), absence of diabetes (p=0.009), history of cataract surgery (p=0.001), higher intraocular pressure (p=0.007), lower spherical equivalent (p<0.001) and increased axial length (p=0.048). CONCLUSIONS: In non-glaucoma individuals, this difference of RNFL thickness in Chinese population should be noted in making disease diagnoses. Meanwhile, multiple ocular and systemic factors are closely related to the thickness of RNFL. Our findings further emphasise the need to demonstrate ethnic differences in RNFL thickness and the specificity of associated ocular and systemic factors, as well as to develop better normative databases worldwide. TRIAL REGISTRATION NUMBER: HES was registered in Chinese Clinical Trial Registry website, and the registry number was ChiCTR-EOC-17013214.
format Online
Article
Text
id pubmed-10359552
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-103595522023-07-22 Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study Wu, Jian Du, Yifan Lin, Caixia Zhu, Yingting Chen, Wei Pan, Qing Zhuo, Yehong Wang, Ningli Br J Ophthalmol Clinical Science PURPOSE: To examine the normative profile of retinal nerve fibre layer (RNFL) thickness and ocular parameters based on spectral-domain optical coherence tomography (SD-OCT) and its associations with related parameters among the Chinese population. METHODS: This population-based cohort Handan Eye Study (HES) recruited participants aged≥30 years. All subjects underwent a standardised ophthalmic examination. Peripapillary RNFL thickness was obtained using SD-OCT. Mixed linear models were adopted to evaluate the correlation of RNFL thickness with ocular parameters as well as systemic factors. R V.3.6.1 software was used for statistical analysis. RESULTS: 3509 subjects (7024 eyes) with the average age of 55.54±10.37 were collected in this analysis. Overall mean RNFL thickness measured was 113.46±10.90 µm, and the thickest quadrant of parapapillary RNFL was the inferior quadrant, followed by the superior quadrant, the nasal quadrant and the temporal quadrant. In the multivariate linear regression model, thinner RNFL thickness was remarkable association with male (p<0.001), older age (p<0.001), increased body mass index (>30, p=0.018), absence of diabetes (p=0.009), history of cataract surgery (p=0.001), higher intraocular pressure (p=0.007), lower spherical equivalent (p<0.001) and increased axial length (p=0.048). CONCLUSIONS: In non-glaucoma individuals, this difference of RNFL thickness in Chinese population should be noted in making disease diagnoses. Meanwhile, multiple ocular and systemic factors are closely related to the thickness of RNFL. Our findings further emphasise the need to demonstrate ethnic differences in RNFL thickness and the specificity of associated ocular and systemic factors, as well as to develop better normative databases worldwide. TRIAL REGISTRATION NUMBER: HES was registered in Chinese Clinical Trial Registry website, and the registry number was ChiCTR-EOC-17013214. BMJ Publishing Group 2023-08 2022-04-05 /pmc/articles/PMC10359552/ /pubmed/35383049 http://dx.doi.org/10.1136/bjophthalmol-2021-320618 Text en © Author(s) (or their employer(s)) 2023. Re-use permitted under CC BY. Published by BMJ. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution 4.0 Unported (CC BY 4.0) license, which permits others to copy, redistribute, remix, transform and build upon this work for any purpose, provided the original work is properly cited, a link to the licence is given, and indication of whether changes were made. See: https://creativecommons.org/licenses/by/4.0/.
spellingShingle Clinical Science
Wu, Jian
Du, Yifan
Lin, Caixia
Zhu, Yingting
Chen, Wei
Pan, Qing
Zhuo, Yehong
Wang, Ningli
Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study
title Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study
title_full Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study
title_fullStr Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study
title_full_unstemmed Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study
title_short Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study
title_sort retinal nerve fibre layer thickness measured with sd-oct in a population-based study: the handan eye study
topic Clinical Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10359552/
https://www.ncbi.nlm.nih.gov/pubmed/35383049
http://dx.doi.org/10.1136/bjophthalmol-2021-320618
work_keys_str_mv AT wujian retinalnervefibrelayerthicknessmeasuredwithsdoctinapopulationbasedstudythehandaneyestudy
AT duyifan retinalnervefibrelayerthicknessmeasuredwithsdoctinapopulationbasedstudythehandaneyestudy
AT lincaixia retinalnervefibrelayerthicknessmeasuredwithsdoctinapopulationbasedstudythehandaneyestudy
AT zhuyingting retinalnervefibrelayerthicknessmeasuredwithsdoctinapopulationbasedstudythehandaneyestudy
AT chenwei retinalnervefibrelayerthicknessmeasuredwithsdoctinapopulationbasedstudythehandaneyestudy
AT panqing retinalnervefibrelayerthicknessmeasuredwithsdoctinapopulationbasedstudythehandaneyestudy
AT zhuoyehong retinalnervefibrelayerthicknessmeasuredwithsdoctinapopulationbasedstudythehandaneyestudy
AT wangningli retinalnervefibrelayerthicknessmeasuredwithsdoctinapopulationbasedstudythehandaneyestudy